Calibration of a light microscope involves determining the distance (in microns) that each division of the reticle represents for each objective attached to your microscope. For stereoscopes each division of the reticle may represent 1 or more millimeters and if you have a zoom scope you may want to mark the zoom settings on your scope where you calibrated the reticle. Rotating the eyepiece with the reticle allows you to orient the scale in different directions for measuring.
The scale on the microscope slide can be used to determine the field of view in your microscope and to calibrate the ocular scale for each objective. On a zoom stereoscope choose specific zoom settings (magnifications) to calibrate. When you are finished calibrating the scope I recommend you write or print the results and tape the paper to your microscope or nearby it for quick reference.
The components chosen for the Panthera have been analyzed down to find the perfect design in terms of practicality and aesthetics.
It is widely used in building, bridge, theme park, monument, landscape, night clubs or exhibition, performances, and other professional places.
LEDProjector Lights Outdoor
You need a microscope slide with a precision scale on it – usually 1 mm scale divided into 0.010 divisions. A micron or micrometer is 0.001 mm or 1/1000th of a millimeter. These microscope slides are available from microscope manufacturers including Motic for a reasonable cost. For stereo microscopes you can use a ruler with a millimeter scale on it.
You repeat this procedure with each of your objectives until you have a list for all your objectives. Below is a calibration for each of my objectives on one of my microscopes. I print this and attach it to my microscope.
LEDProjector Home Theater
For the precise method of measuring subjects, you will need a reticle scale that fits into one of your microscope eyepieces. The reticle requires a retainer ring that screws into the eyepiece and holds it in place. The reticle has a scale on it divided into small divisions. The distance between the divisions is not important only that they are regularly spaced. The reticle scale usually occupies about half the field of view.
The model is fitted with a 300w LED light source, with strong light effect, large-angle water streak effect, and clear gobo. Meanwhile, it is with 6 colors+ open color wheel, prism+ water streak, and zoom function.
The second thing you will need to calibrate your scope is an eyepiece reticule with a scale divided into regular intervals that you place in the back of one eyepiece. To hold the reticle in place you will need a reticle retainer ring. Eyepiece reticles are difficult to keep clean so if possible have the reticle inserted when you purchase a new scope. You only need one reticle per microscope. If you find the reticle distracting, you can buy an additional eyepiece to insert when you don’t need or want the reticle scale.
Calibrating a microscope allows the dimensions of objects or organisms to be measured. Knowing the field of view makes it possible to estimate the size of the specimen by estimating the fraction of the field of view it occupies. A more accurate measuring method involves measuring a subject with an eyepiece reticle that has been calibrated as described above. The reticle can then be used to measure the size of the subject by measuring how many divisions it is with a particular objective and then converting the number of divisions to microns. In order to add scale bars to a photomicrograph you first need to measure the specimen size in microns after calibrating your scope. Some software programs allow you to calibrate the objectives and then automatically add scale bars to an image (e.g. Image J). Using Photoshop or other image editor involves measuring the size of the subject first in microns, then determining the length of the organism in in pixels, and finally calculating the length of the scale bar in pixels that you want to add. A scale bar can then be drawn the correct length with the pencil tool. The length of the scale bar involves simple math to calculate. Scale bars are required on photomicrographs destined for scientific publications in journals. Scale bars can also be added to movies so the audience knows the size of the specimens being viewed.
BiLEDprojector H4
The BA310 is designed for the daily routine work in universities, clinics, laboratories, and life sciences or medical applications.
You only need to calibrate your microscope once, unless you change objectives or eyepieces. Once the microscope is calibrated you can accurately measure the dimensions of a specimen. While taking a series of photographs, I take note of the objective used and the size of the specimen in reticle divisions. I calculate the size in microns later and use the real size of the specimen to make scale bars in Photoshop for the digital photographs as described below.
Putting a scale bar on an image can be done using software that has been calibrated for each objective in a manner similar to calibrating your microscope. Image J is free software that will do this. Some software however, may not allow the user to reposition the scale bar, change the color or thickness of the bar. For these reasons I prefer to use an image editor (Adobe Photoshop) though some other image editors may also work (see references for alternative methods and software). I provide an overview of how scale bars can be added using Photoshop (due to space limitations it is not a detailed step by step tutorial).
A mechanical stage is useful for moving the micrometer scale. Record the total width of the field of view for each objective in millimeters and convert to microns (Table 1). With a 5X objective, the 1 mm scale fits 5 times within the diameter of my microscope, therefore the field of view is 5 mm or 5,000 microns. At 10X the scale fits 2.3 times so the field is 2.3 mm or 2300 microns. With a 20X objective the field of view is 1,150 microns and at 40X it’s 560 microns (on my microscope). For each microscope, the objective and eyepiece used will affect the numbers you get. If you have a 60X and/or 100X objective, calibrate those as well. In my measurements I used 10X wide field eyepieces. If I used 15X or 20X eyepieces I would get different values so would need to calibrate the objectives for different magnification eyepieces. The 10X eyepieces are used most often.
LEDProjector Lights for Room
Our Moticam A Series cameras are designed with microscopy beginners, teaching environments, hobbyists, and small labs in mind.
When someone indicates a picture is magnified 400X this is only an approximation since the size of the picture will change when viewed on different computer screens, tablets, and cell phones or after the image has been cropped. It only suggests that the photomicrograph was taken with a 40X objective. However, if an image has a scale bar any changes in the image size will be reflected by changes in the size of the scale bar. Scale bars are also required on photomicrographs for scientific publications.
LEDlaser projector headlight
Add text to the scale bar e.g. 100 microns or 100 µm or other units. The Greek symbol for micron = µm or just µ and can be added using Photoshops’ glyphs palette found under the Windows menu (Windows > glyphs) or by pressing Alt-230 on your numeric keyboard to get µ. Familiarity with Photoshop is required for the method I use, but this method can be accomplished with other image editing software as well. Below I present a series of screen shots where I describe an overview of the process.
Light microscopes can magnify specimens about 1000X and resolve objects down to 0.2 microns (200 nm, nm = 0.000001 mm). Light microscopes capable of super resolution can detect objects to about 20 nm. Most light microscopes are used to measure organisms such as their length and width to aid in identification. Measuring objects with a light microscope or even a stereo microscope is straight forward, but you will need a few accessories and you will need to calibrate your microscope. Once your microscope is calibrated you can add scale bars to photographs with an image editing program like Photoshop. There is software that permits you to calibrate each objective and then it will automatically add scale bars to the picture (e.g. Image J). Some of these programs have limited ability to customize the bar, fonts, color or the position of the scale bar. In this article, I describe methods to calibrate your light microscope or stereo microscope to measure objects so that you can add scale bars to the images as shown above.
Once the microscope is calibrated you can measure the size of subjects with the eyepiece reticle in divisions and then convert the reticle divisions to microns.
LEDProjector Mini
The disadvantage of using an eyepiece reticle is that it is not easy to measure subjects that are moving (e.g. ciliates). Large ciliates and other organisms must be pinned down by drawing water from under the coverslip. Alternatively you can fix, anesthetize, or kill the organisms though these procedures can alter the organisms shape, size and color. I prefer to measure the dimensions of live organisms that are gently pinned under the coverslip.
This first method for measuring subjects only requires a microscope slide with a micrometer scale. You will put the micrometer slide on the microscope stage, focus on it with each objective starting from low to high power and measure the field of view (diameter). For low magnification objectives you will need to move the 1 mm scale several times to determine the overall diameter of the field of view in mm, which is then multiplied by 1000 to convert to microns.
To calibrate the reticle scale you need to place the micrometer slide on your microscope stage and focus on it. Start with the lowest power objective and then move on to your higher power objectives. The microscope slide is divided into known divisions the smallest being 0.010 mm or 10 microns. When you view the reticle scale over top of the scale on the microscope slide you need to determine how many divisions of the micrometer slide match one division in the reticle.
300W LED Water Streak Light, which is the latest high-quality beam light. It is much lighter and more convenient in the same power with the perfect combination of international advanced electronic control technology and excellent humanized industrial design. It fully complies with the CE standard and supports the international DMX512 signal control mode.
LEDProjector 4K
Once the field of view is determined for each objective, one can estimate an organism’s size by determining the fractional width of the field of view that it occupies. If for instance a ciliate that fits approximately 1/2 the field of view with the 20X objective having width of 1,150 microns then it would be 575 microns, if 1/3 the width is about 383 microns. This method permits you to estimate the size of an organism within ± 10% of its actual size, which is often accurate enough to help you identify some organisms.
You measure the size of the object in pixels with a ruler tool in Photoshop. You already know the true size of the subject from measuring it using the calibrated reticle. Decide what the size you want the scale bar to show 10, 50, 100, 200 microns etc. Solve for X which is the size of the scale bar in pixels. Finally, you draw a line “bar” the length you calculated in pixels and add a text label.
There are two simple ways to measure the size of objects with a microscope. First, I will describe an easy way which can be used to estimate the size of a subject and can be used to measure moving subjects. The second method requires calibrating each objective and using the eyepiece reticle to measure the dimensions of the specimen in reticle divisions and then converting this value to microns. With a stereomicroscope you will follow the same procedure, but use a ruler with a millimeter scale to calibrate the ocular reticle.
Customizable Gobo's $99 EachModel: 300PWaterproof rating: IP66 DMX channel number: 15 channels Operation mode: DMX512 mode, etc. LCD: LED display + button control 300W LED Light Source Color temperature 7000K, average life 20,000 hours 6 Colors + white light, semi color effect Prism: Rotating octagonal prism Optical lens: high precision glue optics Six dynamic glass pattern effects. The water-repellent disk can simulate various water-grain effects and can be superimposed with the pattern to make the pattern water effect. Zoom: Linear magnification focus: linear focus dimming: 0-100% linear adjustment beam angle: 11 degrees -46 degrees strobe: electronic strobe, 0.3-25 times/sec a total of 8 ultra-quiet motors Appearance: high-temperature resistant alloy plastic + aluminum alloy lamp body heat dissipation profile. Protection rating: IP66 Weight: 26.45 LBFixture Size: 330* 232* 513mm Total power: 370W
Most microscope dealers offer both the micrometer slides and the reticles. Before ordering an eyepiece reticle, measure the inner diameter of your microscope eyepiece. Stereo microscopes tend to have larger diameter tubes. Another device that fits into the eyepiece tube that can be used for precise measurements is a filar micrometer. These cost hundreds of dollars. They allow you to move a line over the scale and are also used in astronomy (their use is not described here).
The color wheel consists of 6 fixed colors. Users can easily choose the color they likeand create a perfect lighting effect. At the same time, it can be used with the water gobo wheel, to have abetter effect. Colors can be customized.