Polarization Dependent Loss (PDL) can be defined as the maximum change observed in transmittance or reflectance at a given wavelength as the light is cycled through all possible polarization states. The PDL can be calculated based on the difference between the s- and p-polarization states of light, i.e.,

We have specially opened the "V College" channel, provide more videos and documents about the Vision Master, including software introductory, advanced, advanced and other related learning content, as well as answers to various questions when using. We hope that users can have a more in-depth study and understanding in this channel.

This is difference between the maximum reflectance in the pass-band and the minimum reflectance in the reflect-band. The minimum reflectance in the reflect-band is very often close to 0 dB so that the reflection isolation is typically dominated by the maximum reflectance in the passband. For filters with no absorption, the transmittance and reflectance must add up to unity. Hence, there is often a relationship between the specified reflection isolation in the passband and the sum of the peak IL and ripple in the passband, i.e.,

The VM provides a fully graphical interactive interface, with intuitive and easy-to-understand function icons, simple and easy-to-use interactive logic and drag-and-drop operation to quickly build a visual solution.

This is the region between a pass-band and a reflect band. This regions is called a dead-band or roll-off region and it does not typically contain any transmittance specifications. The roll-off slope is usually inherent in the pass-band and the reflect-band specifications.

Accurately identify defects in the surface, shape, and contour of the workpiece: it can detect small surface scratches and spots based on deep learning technology, which can overcome the surface texture, color, and noise interference of the workpiece; accurately detect the shape and contour defects of the workpiece, which can overcome burrs, colors. The interference of noise. Reliable standard parts comparison tool can locate small differences in workpieces.

The VM provides 1000+ completely self-developed operators and several interactive development tools, supporting a variety of image acquisition equipment, can meet vision requirements of positioning, measurement, identification, and detection.

If the reflection isolation is specified to be -15 dB (corresponding to a reflectance of 3.2 %), then as T+R =1, the minimum transmittance in the passband is given by T=100-3.2=96.8 % which is equivalent to a 0.14 dB transmittance loss. Hence, to achieve a reflectance isolation of -15 dB, the transmittance loss must be less than 0.14 dB. Note that if a minimum allowed transmittance loss of 0.2 dB is specified along with a reflectance isolation of -15 dB, then the overriding transmittance loss to achieve the necessary reflectance isolation is 0.14 dB.

Provide continuous, accurate and high-speed reading of ID information required for component tracking: OCR algorithm based on deep learning can adapt to the recognition of complex background, low-contrast, and deformed characters; One-dimensional code and two-dimensional code recognition algorithms can recognize information codes of multiple formats, different positions, angles, illumination, and effectively overcome the impact of image distortion.

Self-developed by HIKROBOT, VM is a machine vision software that is committed to providing customers with algorithm tools to quickly build vision applications and solve visual inspection problems. Can be used in various applications such as visual positioning, size measurement, defect detection, and information recognition.

The reflect-band can also be specified by defining a center wavelength (CWL), reflect-band width and operating wavelength range, e.g.,

Efficient positioning tool matching tool can overcome the differences caused by sample translation, rotation, zoom and illumination, and quickly and accurately find the position of geometric objects such as circles, lines, spots, edges, and vertices. Provide location information and presence information, which can be used in robot guidance and other vision tools.

This is the average or mean wavelength based on two points on the curve at the same transmittance level. A typical level is at Full Width Half Maximum (FWHM) or -3dB. At this level any ripple or other pass-band defect will not effect the center wavelength calculation.

The VM integrates the SDKs of various interfaces of industrial cameras, smart cameras, vision controllers and other devices, and embeds efficient and stable occupation and control logic, which has good compatibility with external device resources and can establish a complete management mechanism.

Band Pass Filters (BPFs) are used to pass (transmit) a range of wavelengths and to block (reflect) other wavelength on either side of the bandpass. The region of high transmittance is known as the passband and the region of high reflectance is known as the reject or reflect band. The pass-band and reflect-bands are separated by the roll-off region. The complexity of these filters depends primarily on the steepness of the roll-off region, the width of the pass-band and also on the ripple and insertion loss specifications in the pass-band. In the case of a relatively high angle of incidence, polarization dependent loss may also be a consideration.

This is a region of high reflectance. It is specified by a reflect-band width in nm at a certain transmittance level relative to the peak transmittance, e.g.,

The VM algorithm platform is equipped with high-performance deep learning algorithms. After a large number of cases, the optimized algorithm can have good adaptability to common detection products. The deep learning algorithm provides algorithm modules such as classification, target detection, character positioning and recognition, and segmentation. Through the built-in graphical data annotation interface, the complete process from collection, training to detection can be completed within the VM algorithm platform.

including text positioning and character recognition, which are used to predict the text position and the text truth value in the graph respectively.

Usually the passband ripple is specified as the difference between the maximum and minimum transmittance in the passband width (see above figure). Note that this passband ripple is different from that of a substrate etalon ripple.

This is a region of high transmittance. It is usually specified by a pass-band width, peak IL and ripple. The pass-band width is specified in nm at a certain transmittance level relative to the peak transmittance.