Ultrafast Laser Oscillators - ultrafast lasers
Introduction: Photobiomodulation or low-level laser therapy (LLLT;<0.5 W) has been used as a non-invasive treatment for various medical indications. Short (visible; 635-650 nm) and longer (invisible; 810-850 nm and 915-980 nm) near-infrared wavelengths have been commonly used, but power setting deficiencies or incorrect wavelength settings can cause negative outcomes. The 1064 nm wavelength as the longest wavelength is a relative newcomer in high-powered (>0.5 W) laser photobiomodulation therapy (HPL-PBMT) with unique biophysical characteristics.
The two trials which assessed cartilage thickness after 1064 nm HPL-PBMT were particularly impressive since there are few, if any, known treatments that have been able to demonstrably increase knee cartilage thickness.24,33 One trial did not detect significant changes in cartilage thickness after performing treatments twice per week for 6 weeks; however, another trial that involved more frequent daily treatments for just 2 weeks resulted in significantly detectable increases in cartilage thickness, which was detectable even 6 weeks after the cessation of treatment. More studies are needed to determine the extent to which high-powered PBMT is capable of increasing joint cartilage thickness.
The 22 studies meeting the criteria to be included in this meta-analysis have evaluated a variety of outcome measures including changes in pain, function, quality of life, ROM, and strength as well as anatomical structures (Table 1; see online Supplementary file 2, Table S1). Seven of the studies were double-blinded controlled trials.22-28 Thirteen of the studies were single-blinded controlled trials involving blinding either the practitioner or the assessor.8,29-40 No adverse events were reported in any studies except for one study involving patients diagnosed with hemophilic arthropathy, in which one patient experienced paresthesia at the application site and three others had nondescript adverse events, none of which were serious.
There was one 1064 nm HPL-PBMT study of note that did fulfill the criteria for inclusion in our meta-analysis, but that described the successful treatment of localized infectious disease. Onychomycosis is a common fungal toenail infection that can progress to an inability to walk or stand without disabling pain. Researchers reported that 1064 nm HPL-PBMT cured 11% of 56 patients with onychomycosis as compared to 21% cured when anti-fungal was used in combination with topical antifungal medication.47 The study did not meet the selection criteria for inclusion in our meta-analysis because it was an uncontrolled retrospective study. Nonetheless, the results support that more clinical trials are justified for consideration of the use of HPL-PBMT as a therapeutic approach, especially in the treatment of anatomically localized disease. Weber et al. pointed out that the approach is likely to be most useful for treating patients that are unable to tolerate systemic antifungals.
Along the path of light from the source to the target pathologic tissue, there is at first higher absorption by melanin pigments in the skin, which is subtracted from deep tissue photobiomodulation delivery. Melanin represents a group of pigments in the skin that absorbs and reflects light and may be the most significant initial barrier to consider with respect to the depth of tissue photobiomodulation. Depending on the wavelength used, the upfront heat generated from absorption by melanin may be a dominant factor limiting the upper maximal limit of tolerable power intensity, particularly in darker pigmented individuals. The 1064 nm wavelength is distinguished as the longest wavelength that is routinely used.17 Eumelanin is the predominant melanin, and most significantly, 830 nm light is absorbed by eumelanin, but 1064 nm light is not.5 Accordingly, the initial melanin-generated heat produced with typical PBMT is no longer a concern with 1064 nm.
From those 20 studies, 13 examined long-term effects, lasting from 4 to 12 weeks after treatment. In 9 of those 13 studies, data showed that the statistically significant decreases in pain measures were still present in the 1064 nm HPL-PBMT groups. Similar data are found in a majority of the studies when considering other outcome measures. A considerable number of studies focused on the knee and spinal cord (6 each, 12 total), while 3 studies focused on the foot and 3 on the shoulder/arm for 18 controlled trial studies. The four remaining studies did not focus on musculoskeletal disorders: two wounds, one bone, and one primary dysmenorrhea. The greatest categorically favorable pain reduction responses were observed with the treatment of knee pathologies (see online Supplementary file 2, Table S1). One 2020 knee osteoarthritis study included measures of changes in knee cartilage from 3 different ultrasound aspects at 6 weeks after the cessation of treatment.24 High-powered 1064 nm PBMT caused a medium-to-large effect size when looking at changes in cartilage thickness from all three aspects, given that Cohen’s |d| < 0.2 = small effect, 0.2 < |d| < 0.8 = medium effect, and |d| > 0.8 = large effect.20
I see you outside now on your break—Jacob, according to this receipt. Your box-dyed blonde hair—did you use your employee discount on it?—almost touches the crumpled collar of your uniform. You suck on a vape pen, so young I think of the vape as your binky. Your head dissolves into a puff of smoke. I can see your lungs shrivel with every breath. Maybe you should quit.
1064nmFiberLaser
In all of these studies except one, statistically significant improvements were observed in one or more of these areas when comparing baseline measures to data collected at the end of treatment, with the probability value set at the standard P < 0.05. Twenty of the studies used pain as one of the outcome measures, with 19 studies using the visual analog scale (VAS) and one using the Present Pain Intensity Scale. 18 studies showed a statistically significant decrease in pain when comparing the baseline and after-treatment measures within the 1064 nm HPL-PBMT groups. Fourteen of those twenty studies also showed a statistically significant difference when they were compared (1064 nm HPL-PBMT vs control).
Clinical trial studies evaluating the effectiveness of low-level (LLLT) laser photobiomodulation therapy (PBMT) have yielded inconsistent outcomes due to differences in laser parameter settings involving variable power levels, wavelength selection, light coherence, operation modes (pulsed versus continuous), beam sizes, and dosage depending on indications and specific patient populations.1 However, over the past 5 years, significant advances have been made, clarifying our understanding of which factors are most important for achieving reproducibly effective therapeutic outcomes.2-6
This meta-analysis also confirms that 1064 nm HPL-PBMT is also highly effective in promoting wound healing.28,43 Significantly, wound healing is distinguished as one of the simplest and unequivocal measurable PBMT outcomes. Similar to wound healing, the effectiveness of treating oral mucositis with PBMT is indisputable, with easily measurable outcomes and unequivocally positive results. Oral mucositis routinely occurs in patients undergoing hematopoietic stem cell transplantation or radiotherapy ± chemotherapy and can cause extensive pain and suffering. Photobiomodulation has proven to be an effective drug-free treatment for cancer patients undergoing the standard of care treatments.44
1064nm laserpointer
My boyfriend, Adam, says I don’t take enough risks. Motherfucker. Today I took two: I stole that stuff and now this confession.
I’m running out of room on this receipt. If you see me again in the store, blink three times so I know you remember me, that you remember this note, that you care about me. That someone cares about me.
In the twenty-two studies examined, 1064 nm HPL-PBMT caused no serious adverse events, and no significantly negative effects were observed across all outcome measures (Table S1). It is also impressive that there were no significantly negative effects observed after all of our measures, which is consistent with previous early analysis examining musculoskeletal pain.9 This demonstrates and supports the exceptional safety profile of high-powered photobiomodulation as a therapeutic approach.
Official websites use .gov A .gov website belongs to an official government organization in the United States.
Adam says I talk too much but share too little. He says I smell like Twinkies and gasoline. He says I don’t have a high enough sex drive. I’m sure you’ve met him—tall, protruding belly, beard down to his chest, stiff as overly-starched jeans, a botched scorpion tattoo on his forearm. He’s a frequent Bud Light Lime buyer. I used his phone number at checkout, and he had $11.00 in Extra Bucks.
The three studies comparing high-powered 1064 nm to lower-powered PBMT indicated that PBMT of a higher power was required to achieve effectiveness. In one trial involving patients with plantar fasciitis (PF), those treated with 1064 nm high-powered PBMT exhibited better outcomes than those treated with low-powered PBMT.8,40 Another study involving PF patients did not result in any improvements after high- or low-powered PBMT.40 The PF studies may be limited by the ability to identify the target site to aim at the laser given that PF pain has the potential to be referred to as neuronal pain.42 The third study comparing high-powered 1064 nm PBMT to low-powered PBMT showed benefits for both approaches in the treatment of chronic lower back pain.38
The significance level was set at P < 0.05. A statistical method was designed to measure the effect size specifically attributable to 1064 nm HPL-PBMT as compared to a common background. Cohen’s d formula was used for the calculation of the effect size (ES).20,21 The standardized mean of group assessments made before and after treatment was divided by the pooled standard deviation.
1064nm laserdiode
This study conforms to all PRISMA guidelines and reports the required information accordingly. We performed a systematic review of the best evidence using Cochrane guidelines. Our structured question for this review was as follows in Figure 1. We searched the most important and appropriate electronic medical databases including PubMed, Cochrane library, and Google Scholar. We searched for the word “photobiomodulation” restricted to the years 2016-2021. The articles that were deemed to be irrelevant to the research objectives were excluded. After collecting the full texts of articles which were related to the objectives of this study, the references of these articles were reviewed. The related references were identified, and their full texts were reviewed.
1064nm LaserModule
Our meta-analysis concludes that all three diagnoses listed in Table 2 can be effectively treated with high-powered 1064 nm PBMT to provide therapeutic benefits: knee arthritis, wound healing, and spinal disorders. High-powered 1064 nm PBMT had a large positive effect on all three conditions after follow-up assessment (Table 2). Treatment of chronic neck pain and non-specific lower back pain also resulted in a large reduction in pain, but assessment in these studies was limited because the assessment was only done at the end of treatment. Based on the analysis, the data predict that all of these spinal disorders can benefit from high-powered 1064 nm HPL-PBMT, but more clinical validation is needed to achieve recognition and acceptance by third party payors.
Interpretation was based on the values established by Cohen: small effect ≤ 0.2, medium effect 0.2-0.8, and large effect > 0.8.20
Heat can be generated when light is absorbed by water or chromophores such as melanin - the predominant chromophore in skin. At the extreme, the high relative absorption by water, as with a carbon dioxide laser, which uses a light wavelength of 10 600 nm, results in flash boiling with tissue ablation, which is useful for surgical purposes. For photobiomodulation purposes, it is more desirable to consider wavelengths with characteristic minimal absorption of water and/or melanin, so there are both a reduction in heat generation and a greater depth of penetration at the high-power settings needed to reach deep tissue pathologies.5,11-13 The 810-830 nm wavelength has the lowest absorption of water of commonly used PBMT wavelengths14 (Figure S1,15,16Supplementary file 1).
One possible limitation of deep tissue HPL-PBMT studies is the challenge of properly aiming the laser given the potential for nerve-referred pain that is actually caused by distal pathologies. Missing the target pathology may be less likely to happen for the contained anatomy of the knee or toe (onychomycosis), so this may be part of the reason that knee outcomes are so universally positive in this analysis. By contrast, the less reproducibly positive outcomes observed involving the spine or PF foot pain may be improved with an appropriate aiming laser by the hands of a skilled and knowledgeable practitioner.
1064nm laserhair removal
The difference of effect sizes between two separate groups (± 1064 nm HPL-PBMT) was calculated via the subtraction of the ES for each group as a metric for determining the relative efficacy specifically attributable to 1064 nm HPL-PBMT.9
1064 nm wavelength
Positive therapeutic outcomes can be dependent on the ability of laser light to penetrate and ultimately reach pathological tissues.7-10 As light transmits through tissue, it is lost by three processes: reflection, scattering, and absorption of light by water, melanin, or other chromophores. The depth of laser light penetration is dependent on the adjustable laser setting parameters of power density and wavelength.5 Multiple randomized controlled trials that directly compare low-power (< 0.5 W) and high-power (> 0.5 W)laser therapy have proven that high power can be required for efficacy.7-10 The highest power settings that can generate heat may need to be modified, depending on the condition being treated and the response of the patient. The upper limit of high-power laser settings to the patient can be modified in a number of ways, including faster movement of the treatment headpiece, administering therapy in pulsed light modes, using appropriate wavelength selection, and administration of specific cold or cryotherapy prior to laser therapy treatment.
1064nmlight
I regret to inform you that this receipt is inaccurate—I stole Hubba Bubba, a stress ball, Revlon tweezers, and a travel sized pack of Trojan condoms. The items sit in my hoodie pocket, pressing into my stomach like the hot stones they put on your back during massages. I wouldn’t know. I’ve never been to a spa.
Secure .gov websites use HTTPS A lock ( Lock Locked padlock icon ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.
Methods: A comprehensive search of 2016-2021 PubMed, Google Scholar, and Cochrane databases for "photobiomodulation" restricted to clinical trials for patients with a medical diagnosis was done. "1064 nm" content was identified and restricted to high-powered lasers (>0.5 watt). Cohen’s d was calculated for the effect size and the difference was determined as a measure of relative 1064 nm HPL-PBMT efficacy.
By contrast, higher laser power settings are required to reach deeper tissue pathologies, and therefore, the outcome measures for the treatment of musculoskeletal disorders may not be as clear as those observed with overt oral mucositis outcomes. Studies examining low-powered PBMT have commonly led to inconsistent or negative outcomes when indications involve deeper tissue pathologies that absolutely require higher-powered lasers for the light to reach the target pathological tissues. This has an adverse effect on the field of medical PBMT and threatens to cause medical researchers to miss the identification of indications that are in fact highly responsive to the administration of high-powered photobiomodulation.
Sharma et al performed a comparative wavelength study of utility in photoacoustic imaging analysis, a rapidly emerging field of expanding utility that relies on the conversion of light energy to sound energy as first discovered by Alexander Graham Bell.18 The depth of penetration studies determined that the greatest depths of penetration were achieved by the 1064 nm laser with maximum permissible power settings as compared to 532 nm or 800 nm.3
Art by MARIEJULIE LAFRANCE — Bilingual, Multidisciplinary artist, MarieJulie won two art scholarships while studying for her DEC in Arts in letters. She obtained her DEC in 2012. Since 2014, as an illustrator-freelancer MarieJulie uses pencils, brushes, digital software, and fabrics as tools to express her creativity. Diagnosed as a Highly Sensitive Person (HSP), MJ is highly attuned to details, giving her the ability to bring a textured but flowy elegance to her work. Find out more on her website: mariejuliestudio.wordpress.com.
Understanding the clinical biophysics of 1064 nm HPL-PBMT is complicated, but ultimately what matters the most is to determine the optimal laser settings that provide the best clinical outcomes for specific indications. Towards this end, we performed a meta-analysis of all published clinical trials using high-powered 1064 nm wavelength-emitting lasers that was limited to published studies reported within the past 5 years of clinical trials.
Results: The 22 independent studies meeting inclusion criteria focused on knee arthropathies, spine, shoulder/elbow, wound, gynecological, or osteoporosis with evaluation of pain, function, quality of life, range of motion (ROM), and anatomy. Pain was reduced with statistical significance (P<0.05) in 90% of study assessments (n=20) and 100% of studies focused on the knee (n=6). Of 18 studies assessing functional outcome measures, 100% demonstrated statistically significant improvements. Follow-up assessments up to 6 months in 5 knee arthritis studies revealed long-term pain reduction after cessation of treatment. Improvements in wound healing, bone mineral density, and knee cartilage thickness were demonstrated. The largest effect sizes observed were pain reduction in knee arthritis (average Cohen’s d effect size=2.46).
Our systematic meta-analysis method is largely based on, supported by, and confirmed by a previous meta-analysis that focused on the beneficial effects of high-powered laser photobiomodulation therapy on musculoskeletal pain.9 In the previous analysis, investigators concluded that HPL-PBMT can be an effective approach to pain management. We also reached this conclusion and extended these studies further by including newer publications and focusing primarily on the determination of the range and extent of any indications that responded favorably to treatments using specifically the 1064 nm wavelength of HPL-PBMT.
Please cite this article as follows: Penberthy WT, Vorwaller CE. Utilization of the 1064 nm wavelength in photobiomodulation: a systematic review and meta-analysis. J Lasers Med Sci. 2021;12:e86. doi:10.34172/jlms.2021.86.
1064-nmlaserskin treatment
Additional promising results showed significant improvement in various functional measures. The studies that did employ one or more measures of function used such scales as the European Quality of Life Survey (EuroQoL), the Oswestry Disability Index (ODI), the Neck Disability Index (NDI), the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), the Quality of Life - Short Form 36 (SF-36) and the GAITRite System, among others. The various scales and indices were found to be valid and reliable in all studies. Some of the scales take into account various aspects of general functioning such as mobility, self-care skills, common daily activities, pain, anxiety, and social functioning. The ODI and NDI look at functional disability levels related to pain, whereas the WOMAC looks at not only functional activities, such as using stairs, rising from sitting, standing, bending, walking, getting into and out of a car, and putting on and taking off socks, but also pain and stiffness. The GAITRite looks at functional gait parameters in an objective, quantifiable way. Of the 22 studies in this meta-analysis, 18 used some sort of functional outcome measure at baseline, at the end of treatment, and at long-term follow-up, which included 12 of the studies. All 18 studies showed statistically significant improvement in the various functional measures utilized when comparing baseline values to values at the end of treatment within HPL-PBMT groups, and the 12 studies with long-term follow-up continued to exhibit statistically significant improvement in function within the 1064 nm HPL-PBMT groups. When comparing results between 1064 nm HPL-PBMT and control groups, the positive trends continued for the most part. Of the 18 studies using a functional outcome measure, the 1064 nm HPL-PBMT groups showed statistically significant improvement in function when compared to the control groups in 15 of those studies. Ten out of the 12 studies that looked at long-term follow-up found those differences continued with the 1064 nm HPL-PBMT groups outperforming the control groups.
Of all anatomical musculoskeletal categories, the largest amount of data obtained in our study involved the knee (6 studies). Reductions in pain, increases in ROM, and increased functionality were consistently observed. The data conclusively support that HPL-PBMT with 1064 nm treatment can be highly efficacious in the reduction of pain in knee arthritis with the potential for increasing ROM, quality of life, and even cartilage growth.
Importantly, the improved outcome results observed months after the cessation of treatment in multiple studies with large effect sizes indicate that 1064 nm HPL-PBMT can effectively stimulate healing beyond merely providing transient symptomatic relief. Treatment reduced pain in knee (5 studies), spine (2), and shoulder/arm (1) studies and also stimulated increases in knee cartilage thickness, improved quality of life, and improved functional outcomes in assessments performed for times ranging from 6 weeks to 3 months after the end of treatment.
COURTNEY CLUTE — Courtney has an MFA from the University of South Florida. Her work has appeared or is forthcoming in Passages North, Fractured Literary, Emerge Literary Journal, Lumiere Review, Flash Fiction Magazine, Gulf Stream Literary Magazine, Parentheses Journal, and Z Publishing’s Florida’s Emerging Florida Writers: An Anthology. Her flash fiction has been nominated for Best Small Fictions and Best of the Net. You can find her on Twitter at @courtney_clute.
ROM consistently increased in all 9 studies after treatment with 1064 nm HPL-PBMT. These included two studies focused on knee arthritis,24,34 five on various spinal diagnoses (lower back pain,38 herniation,30 cervical spondylosis,29 neck pain,27 lumbar disc protrusion41), and two on shoulder/arm-related subacromial impingement syndrome.22,36
Articles from Journal of Lasers in Medical Sciences are provided here courtesy of Shahid Beheshti University of Medical Sciences
The large effect size seen repeatedly when treating knee anatomies may be in part due to the shorter depth of light penetration that is required to reach pathologic tissues in the knee. By contrast, anatomies with greater potential for referred nerve pain, including PF and spinal diagnoses analyzed within this study, appear to be more challenging to treat based on our analysis of the effect size and under the particular 1064 nm HPL-PBMT treatment settings that were used. Lumbar discs are chronically weightbearing and no therapeutic benefit was seen after the treatment of lumbar disc degenerative disease.37
Owing in part to the clearly positive and reproducible therapeutic results of PBMT, the prevention or treatment of oral mucositis with PBMT is now the most universally accepted, recognized, and established guideline-directed PBMT-utilizing approach in photomedicine and is commonly covered by insurers.45,46 Effective oral mucositis photobiomodulation is routinely performed with low-level light ≤ 100 mW because a negligible depth of tissue penetration is required to reach the targeted superficial highly-regenerating and circulating cells of the oral cavity.
Assessments performed after the cessation of treatment helped determine whether the benefits were sustaining and not merely transient effects. Fourteen studies performed follow-up assessments ranging from 1 to 12 months. All five studies focused on knee arthritis demonstrated a sustained reduction in pain with a large effect, and follow-ups were performed for 6 weeks to 3 mos.24,26,31,33,34 One knee arthritis study detected increased knee cartilage thickness with a large effect detectable 6 weeks after the cessation of treatment that was initially performed for 3 weeks.24 Three spine-related diagnoses had follow-up assessments.29,37,41 A large positive effect was observed for the treatment of cervical spondylosis or lumbar disc protrusion, both 1 month after the cessation of treatment, while no significant benefit was observed for the treatment of lower lumbar disc degeneration. No sustained benefit was observed with foot-related treatments, calcaneal spur or PF after follow-up.
Conclusion: These studies have established that 1064 nm HPL-PBMT can effectively reduce pain, increase ROM, increase functional scores, and increase the quality of life for knee osteoarthritis and spinal disorders, with limitations. More studies are needed for clinical validation of single-trial data detecting changes in musculoskeletal conditions, cartilage thickness and bone density.
Our meta-analysis strongly supports that 1064 nm HPL-PBMT is a safe, tolerable, effective, and long-lasting therapeutic approach for the management of musculoskeletal pain. A specific application for the knee stood out with PBMT being extremely effective. Further clinical trials using high-power 1064 nm PBMT settings with continuous mode or pulse settings are needed to provide greater clinical validation of beneficially responsive non-superficial deeper tissue indications to achieve greater consensus and improved outcomes.
This section collects any data citations, data availability statements, or supplementary materials included in this article.
We thank and gratefully acknowledge Thomas A. Hertel, MSPT, for critical reading and analysis of the manuscript. We would like to thank Mazlum Serdar Akaltun for sharing all mean and SD data measures of changes in pain, cartilage thickness, and functionality scores.24
Basic research by Marshall and Vlkova compared the depth of penetration for commonly used PBMT wavelengths.5 First, they performed a literature-based analysis of reflection, refractive indices (scattering), absorption by water, and absorption by melanin with respect to commonly used wavelengths in PBMT. The researchers pointed out that the refraction index is 3x less for 1064 nm (1.5 cm -1) light than for 810 nm (4.6 cm -1) light and that general reflection, scattering, and absorption by melanin for wavelengths above 1000 nm are uniformly lower, while the 810 nm wavelength is the least absorbed by water. In subsequent experiments, investigators measured the depth of penetration through agarose-based tissue-mimicking media.19 Significantly, at high powers, the investigators determined that the relative energy detectable at 6.2 mm depths was the highest for 1064 nm (47%), followed by simultaneous 810 nm with 970 nm irradiation (37%), and lastly 810 nm (26%).5 The investigators concluded that wavelengths above 1000 nm have negligible absorption and reflection by melanin and that the 1064 nm wavelength has deeper penetration than 810 nm and 970 nm.
The inclusion criteria were (1) clinical trials, (2) use of high-powered lasers with power settings > 0.5 W, (3) patients with a medical diagnosis, (4) comparison of high-powered lasers versus LLLT or placebo lasers or common backgrounds, and (5) use of outcome measures such as pain, range of motion (ROM), quality of life, cartilage thickness, disability indices, bone density, or gait. The exclusion criteria included (1) fundamental research or studies on animals, (2) controlled trials involving patients without a medical diagnosis, (3) review articles, (4) articles which did not have related statistical and clinical data.