Depending on the transparency of the sample, and the wavelength of exciting light, samples can be imaged to a depth of a few hundred micrometers. Maintained scanning over a period of time provides time-lapsed images that allow scientists to observe the dynamics of tagged molecules or structures over time.

Smith, C. L. (2011). Basic Confocal Microscopy. Current Protocols in Neuroscience. doi: 10.1002/0471142301.ns0202s56  currentprotocols.onlinelibrary.wiley.com/.../0471142727.mb1411s81

Canonlenses and focal length

Following each of these steps, the primary or secondary antibody linked fluorophore can be added. In some cases, additional counter stains may be included to reduce background fluorescence.

Some energy is thought to be consumed by non-radiative decay processes, and the difference in energy between the incident and emitted photon is known as Stokes shift. As the system relaxes vibrationally the electron returns to the ground state, releasing the remaining difference between the electron energy levels as a photon. The decay rate generally follows first-order kinetics, with most commonly employed fluorophores emitting within nanoseconds.

Fluorescence is the process by which a photon is absorbed, and another of slightly lower energy, and therefore longer wavelength, is subsequently emitted. Under normal circumstances, the electrons of a fluorophore (a molecule capable of fluorescence) are in a low-energy ground state, which when excited by interaction with an incident photon may be promoted to a higher energy level.

Focal lengthof lens formula

Confocal fluorescence microscopy is a commonly used optical imaging method in biology, combining fluorescence imaging with confocal microscopy for increased optical resolution. This article will discuss the principles of fluorescence and confocal microscopes, and describe the stages of fluorophore selection and sample preparation.

Michael graduated from the University of Salford with a Ph.D. in Biochemistry in 2023, and has keen research interests towards nanotechnology and its application to biological systems. Michael has written on a wide range of science communication and news topics within the life sciences and related fields since 2019, and engages extensively with current developments in journal publications.

Lenses and focal lengthcomparison

As discussed, fluorophores are selected for compatibility with the sample under investigation and favorable spectral properties. The great sensitivity of fluorescent probes means that only a comparatively small number need be present in the sample to achieve a sufficient signal.

Lavrentovich, O. D. (2012) Confocal Fluorescence Microscopy. Optical Imaging and Spectroscopy. doi: 10.1002/0471266965 https://onlinelibrary.wiley.com/doi/full/10.1002/0471266965.com127

Camera lens distance chart

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Croix, C. M., Shand, S. H. & Watkins, S. C. (2018) Confocal microscopy: comparisons, applications, and problems. BioTechniques, 39(6S). doi: 10.2144/000112089 https://www.future-science.com/doi/full/10.2144/000112089

Ijeoma Uchegbu discusses nanomedicine's role in improving medication adherence and developing non-addictive pain relief solutions at ELRIG Drug Discovery 2024.

In practical application, fluorophores are selected by the desired excitation and emission wavelengths, the intensity of returned light (quantum yield), and the fluorescence time. Other considerations that may encourage the use of a particular fluorophore over another include the molecular weight, as larger molecules may be sterically hindered in some applications, the presence of other fluorophores that may provide overlapping signals, and the specificity of the fluorescent label.

Molecular “lock and key” mechanisms can be exploited to ensure that fluorophores bond with structures of interest, potentially only activating or deactivating once in position. Antibodies form highly specific bonds with their target structure and are frequently linked to fluorophores in order to track the number and distribution of the target in situ. More recently, peptide and nucleic acid sequences have been employed to similar effect in identifying cellular components.

Image

Focal lengthexamples

However, the availability and diversity of laser types accommodated by laser scanning confocal microscopy mean that it remains the most popular option.

In cases where proteins need not be preserved, when examining the presence of small molecules for example, alcohol fixation at low temperatures may instead be used. In order to ensure complete penetration of the fixation agent, the cells are exposed to mild detergents, increasing the permeability of the cell membrane.

Antibodies are the most common targeting agent in fluorescent labeling due to their versatility and specificity. Specificity can be improved further by a process known as blocking, flooding the sample with a protein cocktail that occupies non-specific binding sites and exhausts the protein-crosslinking ability of any remaining formaldehyde.

Samples frequently undergo fixation before microscopy to carefully preserve the structural features of the sample. Formaldehyde has historically been used for this purpose, rapidly penetrating cell membranes and forming disulfide bridges between cysteine residues in proteins, preserving even the fine structural details of antigen sites.

The laser utilized in confocal microscopy, besides illuminating a small section of the sample, can instead be used to excite fluorophores, massively improving the sensitivity of detection and signal-to-noise ratio when compared with reflected light from the sample alone.

Unwanted visual noise from the sample, besides light from the spot in focus with the laser, is omitted from the final image by the use of a pinhole aperture that prevents light scattered from higher angles from passing through. The pinhole is placed along the same plane as the sample to ensure that only photons traveling in a direct line from the sample to the microscope are detected. This is said to be in a conjugate focal plane, hence the portmanteau “confocal”.

Image

Lenses and focal lengthchart

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Camerafocal lengthcomparison

Registered members can chat with Azthena, request quotations, download pdf's, brochures and subscribe to our related newsletter content.

News-Medical.Net provides this medical information service in accordance with these terms and conditions. Please note that medical information found on this website is designed to support, not to replace the relationship between patient and physician/doctor and the medical advice they may provide.

Over- or under-populating a sample with fluorophores can be disadvantageous, generating a noisy signal or incomplete structural elucidation, and so care must be taken in selecting an appropriate concentration.

Image

Additionally, significantly lower intensities of laser light may be employed to obtain a sufficient signal, reducing the risks to the sample associated with photon bombardment. Other sub-types of confocal microscope are available, depending on the application, which limits exposure to photons and improves the collection time of images by using a slit or spinning disc in place of a pinhole.

In confocal microscopy a laser beam is focused to a specific depth within a sample, and similarly to ordinary light microscopes, any reflected or emitted light is detected by a properly positioned microscope.

Sanderson, M. J., Smith, I., Parker, I. & Bootman, M. D. (2016) Fluorescence Microscopy. Cold Spring Harbor Protocols, 10. doi: 10.1101/pdb.top071795 https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4711767/

Greenwood, Michael. "What is Confocal Fluorescence Microscopy?". News-Medical. https://www.news-medical.net/life-sciences/What-is-Confocal-Fluorescence-Microscopy.aspx. (accessed November 24, 2024).

Focal lengthcamera

Professor Nancy Ip discusses her groundbreaking neuroscience research, focusing on neurotrophic factors and innovative Alzheimer's disease treatment approaches.

Greenwood, Michael. 2021. What is Confocal Fluorescence Microscopy?. News-Medical, viewed 24 November 2024, https://www.news-medical.net/life-sciences/What-is-Confocal-Fluorescence-Microscopy.aspx.

Learn about the usage of process raman spectroscopy in the optimization of bioreactor monitoring and then improvement of cultivated meat production.

Many naturally occurring compounds are intrinsically fluorescent, and a vast library of additional specially engineered fluorophores is in constant development. Organic fluorophores frequently contain a number of double bonds and polyaromatic structures that provide delocalized electrons throughout the molecule, which are then capable of excitation.

Greenwood, Michael. (2021, January 22). What is Confocal Fluorescence Microscopy?. News-Medical. Retrieved on November 24, 2024 from https://www.news-medical.net/life-sciences/What-is-Confocal-Fluorescence-Microscopy.aspx.

Small fluctuations in temperature can cause issues with focusing the laser and microscope due to changes in the refractive index of the material, and constant evaporation from the cell culture flask only exacerbates this problem.

The repeated activation of fluorophores eventually induces a phenomenon known as photobleaching, leaving the molecule completely unable to fluoresce. In time-sensitive studies, this must be accounted for, as the number of emitted photons will decline following repeated bouts of excitation.

Greenwood, Michael. "What is Confocal Fluorescence Microscopy?". News-Medical. 24 November 2024. .

The image captured is generally in the range of several hundred nanometers, and so large samples are scanned to allow a larger image to be stitched together later. Adjusting the focal point of the laser and microscope along each of the three axes allows scientists to build up a three-dimensional image of the sample of interest.

Nwaneshiudu, A., Kuschal, C., Sakamoto, F. H., Anderson, R. R., Schwarzenberger, K. & Young, R. C. (2012) Introduction to confocal microscopy. Journal of Investigative Dermatology, 123(12), pp.1-5. ohsu.pure.elsevier.com/.../introduction-to-confocal-microscopy

Fixation, by definition, is unsuitable in dynamic microscopy applications that intend to observe the function of the cell or tissue over time. Live-cell imaging raises a number of issues with regards to keeping appropriate cell conditions within the whole microscopy chamber, including temperature, atmospheric composition of CO2 and humidity, and the pH and contents of the cell culture medium.