Collimation meaningin surveying

In X-ray optics, gamma ray optics, and neutron optics, a collimator is a device that filters a stream of rays so that only those traveling parallel to a specified direction are allowed through. Collimators are used for X-ray, gamma-ray, and neutron imaging because it is difficult to focus these types of radiation into an image using lenses, as is routine with electromagnetic radiation at optical or near-optical wavelengths. Collimators are also used in radiation detectors in nuclear power stations to make them directionally sensitive.

In this way, only one color is transmitted through the output slit at a given time. Spectra are then recorded wavelength by wavelength, rotating the grating.

Collimationsynonyms

Image

A collimator is a device which narrows a beam of particles or waves. To narrow can mean either to cause the directions of motion to become more aligned in a specific direction (i.e., make collimated light or parallel rays), or to cause the spatial cross section of the beam to become smaller (beam limiting device).

On the other hand, with GEMINI it is sufficient to increase the maximum delay of the scan, in this case up to one picosecond, to increase the spectral resolution, without any loss of throughput.

Image

Furthermore, gratings have limited efficiency and narrow spectral bandwidth, so that you often need to use two different gratings and then stitch together two separate measurements to record the spectrum of polychromatic light.

CollimationCT

New systems involving multileaf collimators (MLCs) are used to further shape a beam to localise treatment fields in radiotherapy. MLCs consist of approximately 50–120 leaves of heavy, metal collimator plates which slide into place to form the desired field shape.

Although collimators improve resolution, they also reduce intensity by blocking incoming radiation, which is undesirable for remote sensing instruments that require high sensitivity. For this reason, the gamma ray spectrometer on the Mars Odyssey is a non-collimated instrument. Most lead collimators let less than 1% of incident photons through. Attempts have been made to replace collimators with electronic analysis. [citation needed]

In optics, a collimator may consist of a curved mirror or lens with some type of light source and/or an image at its focus. This can be used to replicate a target focused at infinity with little or no parallax.

In the lower panel of the figure, a collimator has been added (blue bars). This may be a sheet of lead or other material opaque to the incoming radiation with many tiny holes bored through it or in the case of neutrons it can be a sandwich arrangement (which can be up to several feet long; see ENGIN-X) with many layers alternating between neutron absorbing material (e.g., gadolinium) with neutron transmitting material. This can be something simple, such as air; alternatively, if mechanical strength is needed, a material such as aluminium may be used. If this forms part of a rotating assembly, the sandwich may be curved. This allows energy selection in addition to collimation; the curvature of the collimator and its rotation will present a straight path only to one energy of neutrons. Only rays that are travelling nearly parallel to the holes will pass through them—any others will be absorbed by hitting the plate surface or the side of a hole. This ensures that rays are recorded in their proper place on the plate, producing a clear image.

For industrial radiography using gamma radiation sources such as iridium-192 or cobalt-60, a collimator (beam limiting device) allows the radiographer to control the exposure of radiation to expose a film and create a radiograph, to inspect materials for defects. A collimator in this instance is most commonly made of tungsten, and is rated according to how many half value layers it contains, i.e., how many times it reduces undesirable radiation by half. For instance, the thinnest walls on the sides of a 4 HVL tungsten collimator 13 mm (0.52 in) thick will reduce the intensity of radiation passing through them by 88.5%. The shape of these collimators allows emitted radiation to travel freely toward the specimen and the x-ray film, while blocking most of the radiation that is emitted in undesirable directions such as toward workers.

Collimationpronunciation

Collimation meaningin laser

A monochromator is an optical instrument which measures the light spectrum. Light is focused in the input slit and diffracted by a grating.

Let us now consider a spectrum containing sharp peaks, thus requiring higher resolution. With a monochromator you should close the output slit or use a diffraction grating with higher dispersion. This would in turn reduce the amount of light on the detector.

The figure to the right illustrates how a Söller collimator is used in neutron and X-ray machines. The upper panel shows a situation where a collimator is not used, while the lower panel introduces a collimator. In both panels the source of radiation is to the right, and the image is recorded on the gray plate at the left of the panels.

Collimationbinoculars

Collimationdefinition telescope

Without a collimator, rays from all directions will be recorded; for example, a ray that has passed through the top of the specimen (to the right of the diagram) but happens to be travelling in a downwards direction may be recorded at the bottom of the plate. The resultant image will be so blurred and indistinct as to be useless.

Optical collimators are also used as gun sights in the collimator sight, which is a simple optical collimator with a cross hair or some other reticle at its focus. The viewer only sees an image of the reticle. They have to use it either with both eyes open and one eye looking into the collimator sight, with one eye open and moving the head to alternately see the sight and the target, or with one eye to partially see the sight and target at the same time.[5][clarification needed] Adding a beam splitter allows the viewer to see the reticle and the field of view, making a reflector sight.

Collimators may be used with laser diodes and CO2 cutting lasers. Proper collimation of a laser source with long enough coherence length can be verified with a shearing interferometer.

When high spectral resolution is needed, to resolve sharp features such as this narrow peak, using a monochromator one has to either use a grating with higher dispersion or to close the output slit.

Collimatedmeaningin Physics

The light intensity at the detector as a function of the delay is called interferogram. It is sufficient to compute a Fourier transform of the interferogram to retrieve the spectrum of the light. In this animation, the GEMINI is first set to zero and then it slowly increases the delay between the two replicas, thus building the interferogram step by step. The measurement is performed until there are no appreciable residual oscillations in the interferogram. In this example, this corresponds to a maximum delay of 300 femtoseconds. At this point, the retrieved spectrum perfectly matches the input spectrum.

The treatment head of a linear accelerator consists of both a primary and secondary collimator. The primary collimator is positioned after the electron beam has reached a vertical orientation. When using photons, it is placed after the beam has passed through the X-ray target. The secondary collimator is positioned after either a flattening filter (for photon therapy) or a scattering foil (for electron therapy). The secondary collimator consists of two jaws which can be moved to either enlarge or minimize the size of the treatment field.

The presence of the two slits and the sequential recording of the light reduce the throughput and increase the measurement time considerably.

This is the GEMINI’s working principle.  The spectrum of the light at the input of the device is measured using a different approach, based on Fourier-Transform spectroscopy. In fact, GEMINI is an interferometer that creates two replicas of the light with a finely tunable delay.  In this way, the light throughput is much higher than a monochromator because the output spectrum is not filtered and there are no input or output slits. Furthermore, GEMINI has no gratings, thus providing extremely broad spectral coverage, from the ultraviolet to the mid-infrared spectral region.

The English physicist Henry Kater was the inventor of the floating collimator, which rendered a great service to practical astronomy. He reported about his invention in January 1825.[1] In his report, Kater mentioned previous work in this area by Carl Friedrich Gauss and Friedrich Bessel.

NIREOS is an innovative Italian company specializing in high-tech spectroscopy devices for scientific research and industrial applications, spanning material science, microbiology, machine vision, cultural heritage, food quality control, ultrafast time-resolved spectroscopy, and many more.

Optical collimators can be used to calibrate other optical devices,[3] to check if all elements are aligned on the optical axis, to set elements at proper focus, or to align two or more devices such as binoculars or gun barrels and gunsights.[4] A surveying camera may be collimated by setting its fiduciary markers so that they define the principal point, as in photogrammetry.

Image

To find the spatial resolution of a parallel hole collimator with a hole length, l {\displaystyle l} , a hole diameter D {\displaystyle D} and a distance to the imaged object s {\displaystyle s} , the following formula can be used R collimator = D + D s l effective {\displaystyle R_{\text{collimator}}=D+{\frac {Ds}{l_{\text{effective}}}}} where the effective length is defined as l effective = l − 2 μ {\displaystyle l_{\text{effective}}=l-{\frac {2}{\mu }}} Where μ {\displaystyle \mu } is the linear attenuation coefficient of the material from which the collimator is made.

Collimators (beam limiting devices) are used in linear accelerators used for radiotherapy treatments. They help to shape the beam of radiation emerging from the machine and can limit the maximum field size of a beam.