Hex Keys - wrench hex key
Schlierencamera
Image 3. The initial hot air from from a heat gun. The images were also captured. Similar to image 2, the video was captured with the new Chronos 4K12 camera. Image size and frame rate are the same.
Feel free to download the files below and make the connecting plates yourself or have them made at the machine shop of your preference.
Optimize Schlieren Projects with Chronos High-Speed CamerasChronos highspeed camera systems offer the portability, ease-of-use, and video quality required by Universities and R&D Labs to understand Schlieren Imaging in-depth. What is Schlieren Imaging? Schlieren Imaging is a technique that allows us to see the subtle changes in the refractive index of fluids. It can reveal the flow of air, temperature variations, and shockwaves that are otherwise invisible to the naked eye.How does Schlieren Imaging benefit from Chronos High Speed Cameras? High-speed cameras coupled with a Schlieren visualization setup can capture rapid changes in air density or temperature that are not visible by the naked eye. With Chronos High-Speed Cameras, unlock the intricacies of Schlieren Imaging processes and get ready for detailed analysis and visualizations, all with unparalleled efficiency. Key Benefits:All-in-One: Completely standalone, untethered operation with a 5″ inch touchscreen display and battery for portability.Clear Imaging: Record events at 1000FPS+ and capture distortions in light Playback Option: See your Schlieren footage on your Camera screen for in-depth analysisResearch Enhancement: Visualize, measure, and comprehend your Schlieren projects Image 1. Filmed with the Chronos 1.4 Monochrome High-Speed Camera, this Schlieren Imaging cut off percentage increasing with the image intensity decreasing uniformly. The image was captured at 100 fps, exposure time was 250us. From left to right cut off percentage is 0, 25, 50, 75 and 100%.Image 2. Images showing a candle being blown by the air from a heat gun. The video was captured with the new Chronos 4K12 camera. Image size 3840 X 2160, video recorded at 937 fps 8-bit.Image 3. The initial hot air from from a heat gun. The images were also captured. Similar to image 2, the video was captured with the new Chronos 4K12 camera. Image size and frame rate are the same.How does Schlieren Imaging work?In a uniform medium, light travels without deviation. However, when the medium is disrupted by changes in pressure or temperature, its density fluctuates, altering its refractive index. As a result, a beam of light passing through this changing density can no longer follow a straight path; it bends and twists. Enter the “knife-edge,” a thin, rigid object strategically placed in the light’s path. It filters out the unaffected rays, allowing only those bent by the changing medium density to create the captivating images you’ll see on your screen.Figure 1. Schematic diagram of the Schlieren Imaging setupApplicationsLenses Defect TestingShock Wave Testing in High Speed FluidsGas Leak Testing A. Main componentsThe following list shows the different elements in the Kron Technologies’ Schlieren setup. The test rig was used to capture high-speed videos and the images presented at Krontech.ca. The list can serve as a guide for those interested in building a Schlieren imaging setup. The essential items are the parabolic mirror, the light source, the camera and the knife edge. Other elements are included as well. Feel free to look for other alternatives that allow you to build your Schlieren system in a more cost effective way.Spherical mirror, diameter: 203 mm, focal length: 1600 mmLED The LED source used, DigiKey product number SST-20-W40H-A120-J5402, is no longer manufactured. Please refer for a similar item at DigiKey.comHigh-speed cameraKnife edge B. Extra componentsPower supply for the LEDXY-axis C. Optomechanical componentsThe different elements used for the Schlieren setup, except the spherical mirror, were mounted on a breadboard. The camera and the knife edge were mounted each on an XY-axis stage for precise placement. There were also other optomechanical components used. They were purchased at Thorlabs.com.BreadboardMounting basePost holderOptical postRight angle clampMounted Standard Iris, Ø25.0 mm Max Aperture The XY-stages contain 4mm thread holes while the breadboard has 6mm thread holes. To connect these two components a couple of plates were designed. One was to join the breadboard and the XY-stage. One more plate was used to couple the upper surface of the XY-stage to the optical components. Feel free to download the files below and make the connecting plates yourself or have them made at the machine shop of your preference.Lower Coupling SurfaceLower Coupling Surface Step*Upper Coupling SurfaceUpper Coupling Surface Step* *Step can be accessed through IntercomSome things to consider when choosing a high-speed camera for Schlieren Imaging:
Schlierentexture
The essential items are the parabolic mirror, the light source, the camera and the knife edge. Other elements are included as well. Feel free to look for other alternatives that allow you to build your Schlieren system in a more cost effective way.
Image 2. Images showing a candle being blown by the air from a heat gun. The video was captured with the new Chronos 4K12 camera. Image size 3840 X 2160, video recorded at 937 fps 8-bit.
Schlierenoptics
The LED source used, DigiKey product number SST-20-W40H-A120-J5402, is no longer manufactured. Please refer for a similar item at DigiKey.com
The XY-stages contain 4mm thread holes while the breadboard has 6mm thread holes. To connect these two components a couple of plates were designed. One was to join the breadboard and the XY-stage. One more plate was used to couple the upper surface of the XY-stage to the optical components.
The following list shows the different elements in the Kron Technologies’ Schlieren setup. The test rig was used to capture high-speed videos and the images presented at Krontech.ca. The list can serve as a guide for those interested in building a Schlieren imaging setup.
Schlierenmeaning
High-speed cameras coupled with a Schlieren visualization setup can capture rapid changes in air density or temperature that are not visible by the naked eye. With Chronos High-Speed Cameras, unlock the intricacies of Schlieren Imaging processes and get ready for detailed analysis and visualizations, all with unparalleled efficiency.
We keep science moving forward by offering over 2.5 million products and extensive support services to the research, production, healthcare, and science education markets. Count on us for an unrivaled selection of lab, life sciences, safety, and facility management supplies—including chemicals, equipment, instruments, diagnostics, and much more—along with exceptional customer care from an industry-leading team that’s proud to be part of Thermo Fisher Scientific.
Schlierenpronunciation
What is the size and distance from the subject? Chronos offers a selection of lenses from microscope to 12.5mm-75mm to capture events near or far.
Schlieren Imaging is a technique that allows us to see the subtle changes in the refractive index of fluids. It can reveal the flow of air, temperature variations, and shockwaves that are otherwise invisible to the naked eye.
Schliereneffect
What is the lighting sensitivity/contrast required to capture the event? Chronos range from ISO 320-16,000 depending upon model and sensor type (color or monochrome).
The different elements used for the Schlieren setup, except the spherical mirror, were mounted on a breadboard. The camera and the knife edge were mounted each on an XY-axis stage for precise placement.
Schlierenpattern
In a uniform medium, light travels without deviation. However, when the medium is disrupted by changes in pressure or temperature, its density fluctuates, altering its refractive index. As a result, a beam of light passing through this changing density can no longer follow a straight path; it bends and twists. Enter the “knife-edge,” a thin, rigid object strategically placed in the light’s path. It filters out the unaffected rays, allowing only those bent by the changing medium density to create the captivating images you’ll see on your screen.
Chronos highspeed camera systems offer the portability, ease-of-use, and video quality required by Universities and R&D Labs to understand Schlieren Imaging in-depth.
What is the size and distance from the subject? Chronos offers a selection of lenses from microscope to 12.5mm-75mm to capture events near or far.
What is the lighting sensitivity/contrast required to capture the event? Chronos range from ISO 320-16,000 depending upon model and sensor type (color or monochrome).