What can anOCTscan detect
If your pupils are very small or if the doctor wants an image of a very specific area, your pupils may be dilated with medicated eye drops.
USB Cameras are imaging cameras that use USB 2.0 or USB 3.0 technology to transfer image data. USB Cameras are designed to easily interface with dedicated computer systems by using the same USB technology that is found on most computers. The accessibility of USB technology in computer systems as well as the 480 Mb/s transfer rate of USB 2.0 makes USB Cameras ideal for many imaging applications. An increasing selection of USB 3.0 Cameras is also available with data transfer rates of up to 5 Gb/s.
Please select your shipping country to view the most accurate inventory information, and to determine the correct Edmund Optics sales office for your order.
OCTeye test side effects
The detail that can be visualized with an OCT is at such high resolution that doctors can see much finer details. The resolution of OCT is finer than 10 microns (10 millionths of a meter), which is better than MRI or ultrasound.
Optical coherence tomography (OCT) is a noninvasive imaging technology used to obtain high-resolution cross-sectional images of the retina. OCT is similar to ultrasound testing, except that imaging is performed by measuring light rather than sound. OCT measures the retinal nerve fiber layer thickness in glaucoma and other diseases of the optic nerve.
Optical coherencetomographyangiography
Optical coherence tomography is a way for optometrists and ophthalmologists to image the back of the eye including the macula, optic nerve, retina, and choroid (a thin layer of tissue that is part of the middle layer of the wall of the eye).
Optical coherence tomography is a noninvasive imaging technology used to obtain high-resolution cross-sectional images of the retina. OCT obtains images by measuring light instead of sound. The test takes five to 10 minutes and can be used to evaluate many eye conditions.
OCTeye test results
As a result, OCT not only provides much greater detail than other methods, but it also shows exactly which layer of the retina is accumulating fluid causing edema or swelling. OCT can also be used to track the healing or resolution of that swelling.
Optical coherence tomography works by using interferometry, which makes it possible to image tissue with near-infrared light rather than with gamma rays or ultrasound. Interferometry works by shining a beam of light into the eye, which is reflected by tissues at different depths. Images are built based on these reflections.
Availability is limited, so buy before these products disappear. Sorry, we cannot accept returns. Receive up to 80% off select products.
During an eye examination, optometrists and ophthalmologists can view the back of the eye and its anatomy. However, sometimes they need more detail or need to inspect details right below the surface, which is difficult to view with standard techniques. Some describe OCT as an “optical ultrasound” because it provides cross-sectional images.
OCTeye test price
Chopra R, Wagner SK, Keane PA. Optical coherence tomography in the 2020s—outside the eye clinic. Eye. 2021;35(1):236-243. doi:10.1038/s41433-020-01263-6
Optical coherencetomographymachine
Edmund Optics offers a variety of USB Cameras suited to meet many imaging needs. EO USB Cameras are available in both CMOS as well as CCD sensor types making them suitable across a larger range of applications. USB Cameras contain out-of-the-box functionality for quick setup and software is available to download for most models. USB Cameras using low power USB ports, such as on a laptop, may require a separate power supply for operation.
OCTscan
Aumann S, Donner S, Fischer J, Müller F. Optical coherence tomography (OCT): principle and technical realization. In: Bille JF, ed. High Resolution Imaging in Microscopy and Ophthalmology. Cham, Switzerland. Springer International Publishing; 2019:59-85. doi:10.1007/978-3-030-16638-0_3
By Troy Bedinghaus, OD Troy L. Bedinghaus, OD, board-certified optometric physician, owns Lakewood Family Eye Care in Florida. He is an active member of the American Optometric Association.
OCT images to approximately 2 to 3 millimeters below the surface of the tissue. Images are obtained clearly through a transparent window, such as the cornea. The light that is emitted into the eye is safe, so no damage will occur.