Bright fieldmicroscope diagram
Figure \(\PageIndex{1}\): TEM image of a tissue paper sample in bright field mode (left) and dark field mode (right). Image author: Zephyris (Richard Wheeler, Wikipedia), used under Creative Commons Attribution-Share Alike 4.0 International license.
One of the main differences between the bright field and dark field mode is which electron populations are used to construct the TEM image. Bright field image is the most common image generated with a TEM. Some areas of the sample can absorb or scatter electrons and appear darker, while other areas that transmit electrons appear brighter. In the bright field image the unscattered (transmitted) electron beam is selected with the aperture, and the scattered electrons are blocked. Since the unscattered beam is selected, areas with crystalline or high mass materials will appear dark. On the other hand, in dark field mode, the unscattered electron beam is excluded from the aperture, and the scattered electrons are selected instead. Hence, the areas where there are no electron scattering and (e.g, the areas around the sample) will be black, while the areas with materials will appear bright. This technique can be used to enhance contrast when the bright field image is not clear enough, especially when imaging crystalline features that are too small or are drowned out of view. It can also be used to study the crystal lattice, crystal defects, stacking faults, dislocations and particle/grain size.
Bright fieldmicroscope
TEM: Bright field versus dark field is shared under a CC BY-SA license and was authored, remixed, and/or curated by LibreTexts.
Darkfieldmicroscope
This MS PepSearch program (read more...) was developed for batch processing of both proteomics and metabolomics data, in which hundreds or thousands of unknown tandem mass spectra can be processed in a single run.
MS Interpreter (read more...) is a tool that enables the analysis of mass spectra based on the chemical structure of the underlying compound and the chemical formulas of its fragment ions. Now works for high and low mass accuracy spectra.
The LibreTexts libraries are Powered by NICE CXone Expert and are supported by the Department of Education Open Textbook Pilot Project, the UC Davis Office of the Provost, the UC Davis Library, the California State University Affordable Learning Solutions Program, and Merlot. We also acknowledge previous National Science Foundation support under grant numbers 1246120, 1525057, and 1413739. Legal. Accessibility Statement For more information contact us at info@libretexts.org.
TEM dark field and light field image can be used to characterize the size and morphology of the sample as well as their crystal lattice. The most common sources of image contrast are particle mass and crystallinity. Heavier atoms scatter electrons more intensely than lighter atoms. Hence, in bright field mode, the regions with heavier atoms are darker, while in dark field mode these regions are brighter. In biological and polymeric samples with low atomic number, staining can help enhance the image contrast. Samples that are more crystalline are also more strongly diffracted and will appear darker in bright field mode, and brighter in dark field mode. The most common sources of error associated with TEM images are associated with aligning and positioning a sample. It is also important to note that the smaller the aperture size, the higher the contrast will be.