DCS setupcost

* All prices are quoted net of the statutory value-added tax and shipping costs and possibly delivery charges, if not otherwise described

I want to confirm, is this possible/supported? As I am aware, the FQDN hostname must same as the Windows Server hostname.

I want to confirm, is this possible/supported? As I am aware, the FQDN hostname must same as the Windows Server hostname.

DCS setupjoystick

Installing the Management Server and Unified Management Console with Multi-Server FQDNWith a multi-server FQDN configuration, the primary server and all tomcat component servers are installed with the exactsame logical fully qualified domain name. Your DNS or Load Balancer will dynamically resolve the FQDN logical name toa physical IP address based on server availability and/or load balancing scheme. Most modern data centers achieve highavailability in a similar way, resolving IP addresses to online servers dynamically, so as not to require clients (agents) andother servers to manage IP addresses. Figure Installing with multi-server FQDN depicts 1 through N agents requestingIP resolution given a single FQDN logical name, and then communicating with a non-specific server manager; with eachserver dependent upon a centralized database.Configuration of individual multi-server FQDN instances (after primary server installation) is as detailed in the sectionInstalling Management Server along with Tomcat using production mode , with the additional following constraints:• The same logical name (FQDN) must be used to register all servers in a multi-server environment, including theprimary server• When installing a new tomcat component server instance in a multi-server environment, the tomcat componentinstance being installed must not resolve the FQDN logical name to any IP address other than its own. This can easilybe achieved by adding a temporary entry in the localhosts host file and/or unsetting the corporate DNS under networkadaptor settings (e.g. you can use Google's DNS 8.8.8.8 until the installation is complete). Note that the database muststill resolve so you will likely have to add an entry for that as well.• After installation, a different UMC username must be used if signing into multi-servers concurrently (A single usershould be logged in only once at any give time across the entire multi-server environment). If you log into a 2nd serverusing the same username, the session on the previous server will be invalidated.• Administration with the UMC web portal requires a DNS or Load Balancer that supports sticky sessions; unless youedit your localhost's hosts file and set a fixed IP entry for the FQDN when using the UMC webportal.

5 pole cable plug max. 12 A / 400 V. Five contact pins: 5 x Ø 1.80 mm.IP67 power plug in PBT plastic housing in YM series size 20.The plug is suitable for Ø 1 - 11.5 mm cable. The IP protection is provided by the plug with a Ø 6.5 - 12 mm cable.The cable connection size is 2.5 mm (AWG 14) to 4 mm (AWG 12).The plug can be assembled via crimped connection and soldered connection with the cable.The light power plug for signal transmission in industrial environments with a length of 57 mm.The YM series with a plug housing made of PBT plastic, to ensure high stability and multi-core structuresThe connector is waterproof and dustproof according to IP67 protection class.The secure threaded connection on the plastic plug protects against signal interruption and power interruption.The maximum rated power for the mains plug is max. 12 amps.The max. Operation Voltage from the power plug is rated at 400 volts.Series production of the YM connector is suitable for multiple applications.Length: 57 mmWidth: 29.2 mm

Image

Image