If you wish to purchase a complete set of the exact items used in the below setup, please email xk@xkglow.com and we will send you a Paypal invoice for your convenience.

Coherentlight

The image to the left depicts a white light source (top) and its distribution of component colors. The coherence length length is inversely proportional to the bandwidth, so the coherence length is very short. The "random" noise of white light produces an inference signal only when the optical path difference between reference and test paths is less than the coherence length of the beam. This can be seen in the resultant wave at the bottom. That center fringe of highest intensity is our point of zero optical path difference and essentially the probe of the interferometer.

Interferometry

The John A. Dutton Institute for Teaching and Learning Excellence is the learning design unit of the College of Earth and Mineral Sciences at The Pennsylvania State University.

The College of Earth and Mineral Sciences is committed to making its websites accessible to all users, and welcomes comments or suggestions on access improvements. Please send comments or suggestions on accessibility to the site editor. The site editor may also be contacted with questions or comments about this course.

Coherence scanninginterferometry

Author: Mark Fedkin, John A. Dutton e-Education Institute, College of Earth and Mineral Sciences, Penn State University.

The instrument works by scanning in Z and recording the Z position for each and every pixel on the detector for where zero optical path difference (ZOPD) occurred. The objectives are designed so the internal reference and the test path have zero optical path difference at the focal plan of the objective. So, as the scanner moves through Z, when the surface starts to come into focus for each pixel, the inference fringes will become measurable, and the Z position of the center fringe (highest intensity) is recorded as it passes through ZOPD. Our detector is a 1024x1024 camera, which means our scan results in 1,048,576 (x,y,z) coordinates that make up the image.

If you are searching for a truly unique way of dressing up your interior, look no more! Our all new fiber optic kits are just what you need. Sure those interior design lines might look cool during the day, but once the sun goes down it gets a little, well, dark. Cue the lights…..the light pipe that is! Paired standard with one of our XKchrome Mini Bluetooth controllers, the features never stop. Install is a breeze with the integrated mounting tab and included 12V plug. Welcome to the future!

Whitelight interferometry

Image

CSI refers to a class of optical surface measurement methods wherein the localization of interference fringes during a scan of optical path length provides a means to determine surface characteristics such as topography, transparent film structure, and optical properties. See Wikipedia for more information about Coherence scanning interferometry.