Silt Curtains are a proven form of quality environmental protection for waterways. Silt Curtains control the settling of silt, preventing these particles from spreading within the waterway. This device is predominantly suited for dredging, excavation, piling operations and rock walling to name a few marine construction activities. Comes standard in 20m lengths however custom sizes can be manufactured.

Our Concrete Anchors and Weights are designed to work in conjunction with our aquatic silt and sediment control products such...

Silt Curtains are available in 2 class types; Class 1 is suitable for still waters, ponds and streams, while Class 2 is suitable for moving waters, tidal areas and sea walls. Both are available with a standard 1 metre and 2 metre skirt, or skirts can be custom made to a specific height. Silt Curtains are manufactured with closed cell foam floats and are available in standard 20 metre lengths. Heavy duty connectors may be applied for joining 20 metre sections together. If standard sizing does not meet your requirements, custom made Silt Curtains can be manufactured.

Fire symbolscopy and paste

Doors so indicated, which may be secured when certain parts of the premises are not in use, are provided with special fastenings.

Having regard to the relevant British Standard and the need to provide 30 minutes fire resistance the standard provided by the construction is so indicated.

Fireicon

We can provide expert advice on the types of temporary and permanent erosion control solutions, including installation, environmental compliance and re-vegetation.

Architects have their own abbreviations, symbols and drawing conventions to enable all persons in their profession to understand drawings produced for their use. Drawing conventions are subject to BS 1192: 2007 Collaborative production of architectural, engineering and construction information. The current fire protection drawings standard is BS 1635: 1990 Recommendations for graphic symbols and abbreviations for fire protection drawings . However, many fire engineers do not use the current standard and the symbols below are used. Many of the following symbols are used by the British Fire Service and most probably based on BS 1635: 1970. When marking up a drawing you can use symbols of your own choice, providing you create a legend showing what each symbol represents. Depending on the reason for the drawing, Means of Escape for instance, you may use the symbol to show an area to be covered, in accordance with the current British Standard, not the exact location and the symbols below would be acceptable. Other times, an emergency lighting engineer for instance would require to show the exact location of a luminaire to enable the electrician to fit it in accordance with the current British Standard. In this situation BS 1635: 1990 would be more useful for the purpose.

We can supply and install a range of Marine and Waterways Protection products including Silt Curtain (Turbidity Curtain), Aquatic Weed Boom, Fence Booms and Containment Booms.

Symbol offireelement

We can supply and install the following types of erosion control blankets; Jute Mesh, Jute Mat, Coir Blankets, Coir Mesh and Geofabric.

You could also try this interpretation of a few of the BSI Current Symbols you may find them useful. Included are the ones that are best suited to Fire Safety and not fire engineering (mechanical or electrical) drawings.

We provide dust management and soil stabilisation using a cost effective spray on polymer which creates a durable coating over ground cover.

Firesymbol text

There are only -7 Silt Curtain - 20m (Class 1 ( Non Tidal ) / 1m) available in stock. Please decrease the quantity to be able ot proceed

Silt Curtains are a proven form of quality environmental protection for waterways. Silt Curtains control the settling of silt, preventing these particles from spreading within the waterway. This device is predominantly suited for dredging, excavation, piling operations and rock walling to name a few marine construction activities.

Fire Symbols (Both Libraries) –  Download Fire Certificate Symbols (older standard) – Download BSI Current Symbols – Download

Where the degree of fire resistance is accepted as exceeding 30 minutes, that period is as shown in minutes. Associated fan lights and transom lights over these doors are of fire resisting glazing and fixed shut

Doors so indicated are fitted with devices, other than rising but hinges, which will maintain the door(s) effectively self-closing.

Fire symbolsand meanings

We have the expertise to advise on the various options for revegetation treatments and products tailored for the particular site and soil conditions.

Firesymbol drawing

If you can’t find the right solution at Aussie Environmental, chances are it doesn’t exist! We only provide the highest quality products across our enormous range… and we import nearly all of them ourselves. That means you’ll get a reliable solution that makes light work of your issue… and you’ll get it for a crazy, direct-to-consumer price!

As an Aussie owned and operated company, we want to serve our country right. That’s why we provide affordable freight and shipping Australia-wide. In the unlikely event you’re unhappy with your freight cost, simply get in touch with our friendly team. We’ll see if we can find you a better option, to get your product delivered on time and on budget!

Our Coir Logs have a 2-3 year lifespan which allows for full plant and soil establishment, natural plant invasion and land stabilisation.

Available in 125mm & 200mm diameters, both 3m in length Absorbent Floating Booms are ideal in marine settings where oil...

Worried about ordering online? Afraid of getting the wrong product? Our certified erosion and sediment control experts work tirelessly to ensure you get the right product for your needs, the first time around. But just in case, we also protect you with our 14-day money-back guarantee!If you don’t like your product, simply send it back to us in an unused and resalable condition in 14 days. We’ll refund you every cent you paid, no questions asked!

Doors so indicated are provided with automatic releases which are designed to hold a fire resisting door or leaf of a fire resisting door in the fully open position and to permit the door or leaf to close automatically upon the actuation of the fire alarm system.