Linear polarization

Mar 13, 2023 — With anti-androgen and estrogen therapy, you might notice changes as little as 1 month after starting medication. The maximum effects take place ...

The LibreTexts libraries are Powered by NICE CXone Expert and are supported by the Department of Education Open Textbook Pilot Project, the UC Davis Office of the Provost, the UC Davis Library, the California State University Affordable Learning Solutions Program, and Merlot. We also acknowledge previous National Science Foundation support under grant numbers 1246120, 1525057, and 1413739. Legal. Accessibility Statement For more information contact us at info@libretexts.org.

This page titled 9.6: Wave Polarization is shared under a CC BY-SA 4.0 license and was authored, remixed, and/or curated by Steven W. Ellingson (Virginia Tech Libraries' Open Education Initiative) via source content that was edited to the style and standards of the LibreTexts platform.

The real optic glass lens is wrapped with a metal band which can be dismantled by unscrewing the threads where the metal band meets. This magnifying glass ...

Polarization refers to the orientation of the electric field vector. For waves, the term “polarization” refers specifically to the orientation of this vector with increasing distance along the direction of propagation, or, equivalently, the orientation of this vector with increasing time at a fixed point in space. The relevant concepts are readily demonstrated for uniform plane waves, as shown in this section. A review of Section 9.5 (“Uniform Plane Waves: Characteristics”) is recommended before reading further.

What is polarization of waves in Physics

Note that \(\widetilde{\bf E}_y\) is identical to \(\widetilde{\bf E}_x\) except that the electric field vector now points in the \(+\hat{\bf y}\) direction and has magnitude and phase that is different by the factor \(E_y/E_x\). This wave too is said to exhibit linear polarization, because, again, the direction of the electric field is constant with both time and position. In fact, all linearly-polarized uniform plane waves propagating in the \(+\hat{\bf z}\) direction in lossless media can be described as follows: \[\widetilde{\bf E} = \hat{\bf \rho}E_{\rho} e^{-j\beta z} \nonumber \] This is so because \(\hat{\bf \rho}\) could be \(\hat{\bf x}\), \(\hat{\bf y}\), or any other direction that is perpendicular to \(\hat{\bf z}\). If one is determined to use Cartesian coordinates, the above expression may be rewritten using (Section 4.3)

Compound microscopes are widely used in fields such as biology, medicine, and materials science for a variety of applications. In biology, they are essential for studying cell structures, observing microorganisms, and analyzing tissue samples. In medicine, compound microscopes are used for diagnosing diseases, examining blood samples, and conducting research in fields like microbiology and pathology.

In engineering applications, circular polarization is useful when the relative orientations of transmit and receive equipment is variable and/or when the medium is able rotate the electric field vector. For example, radio communications involving satellites in non-geosynchronous orbits typically employ circular polarization. In particular, satellites of the U.S. Global Positioning System (GPS) transmit circular polarization because of the variable geometry of the space-to-earth radio link and the tendency of the Earth’s ionosphere to rotate the electric field vector through a mechanism known Faraday rotation (sometimes called the “Faraday effect”). If GPS were instead to transmit using a linear polarization, then a receiver would need to continuously adjust the orientation of its antenna in order to optimally receive the signal. Circularly-polarized radio waves can be generated (or received) using pairs of perpendicularly-oriented dipoles that are fed the same signal but with a \(90^{\circ}\) phase shift, or alternatively by using an antenna that is intrinsically circularly-polarized, such as a helical antenna (see “Additional Reading” at the end of this section).

A commonly-encountered alternative to linear polarization is circular polarization. For an explanation, let us return to the linearly-polarized plane waves \(\widetilde{\bf E}_x\) and \(\widetilde{\bf E}_y\) defined earlier. If both of these waves exist simultaneously, then the total electric field intensity is simply the sum:

Polarized wavemeaning

When written in this form, \(\phi=0\) corresponds to \(\widetilde{\bf E}=\widetilde{\bf E}_x\), \(\phi=\pi/2\) corresponds to \(\widetilde{\bf E}=\widetilde{\bf E}_y\), and any other value of \(\phi\) corresponds to some other constant orientation of the electric field vector; see Figure \(\PageIndex{1}\) for an example.

Dissecting microscopes consist of two separate optical paths with eyepieces and objective lenses that provide a three-dimensional (3D) view of the specimen. They typically feature a zoom knob to adjust magnification, a focus knob for precise focusing, and an adjustable light source for illumination.

Polarization of electromagnetic waves pdf

To begin, consider the following uniform plane wave, described in terms of the phasor representation of its electric field intensity:

The rotation of the electric field vector can also be identified mathematically. When \(E_x = E_0\) and \(E_y = +jE_0\), Equation \ref{m0131_eCirc1} can be written:

Compound microscopes consist of a single optical path with two sets of lenses: the objective lens located near the specimen and the eyepiece lens positioned near the observer's eye. They also feature a stage where the specimen is placed, a focus mechanism for adjusting the clarity of the image, and an illumination system typically located beneath the stage.

Compound microscopes, on the other hand, are designed for observing small, transparent specimens at high magnification. These microscopes use multiple lenses to magnify the image of the specimen, allowing for detailed examination of cellular structures, microorganisms, and histological samples.

Polarizedand unpolarized light

Easy-to-attach bayonet mechanism with lock ... A-mount lens adapter for E-mount camera bodies ... A-mount lens adapter; Compatible with a wide range of lenses.

A wave is said to exhibit linear polarization if the direction of the electric field vector does not vary with either time or position.

MAGNIFICATION meaning: 1 : the act of making something look larger than it is the act of magnifying something; 2 : the larger appearance of an object when ...

A wave is said to exhibit circular polarization if the electric field vector rotates with constant magnitude. Left- and right-circular polarizations may be identified by the direction of rotation with respect to the direction of propagation.

Polarisedwavedefinition a level

Jun 10, 2021 — The concept shown in the video above by Anderson is incredibly simple: it uses a box with either a pinhole or a lens attached to the front which ...

The versatility of dissecting microscopes makes them suitable for various applications across different fields. In biology, they are used for studying plant and animal anatomy, conducting dissections, and examining specimens in environmental science. In industries such as electronics and manufacturing, dissecting microscopes are employed for inspecting small components and conducting quality control checks.

\[\hat{\bf \rho} = \hat{\bf x}\cos\phi + \hat{\bf y}\cos\phi \nonumber \] yielding \[\widetilde{\bf E} = \left( \hat{\bf x}\cos\phi + \hat{\bf y}\cos\phi \right) E_{\rho} e^{-j\beta z} \label{m0131_eLinAI} \]

SciOptic 500 Trinocular Zoom Microscope with Built-In Light · $1,325.00 · Best Sellers. Popular Products ...

If the phase of \(E_x\) and \(E_y\) is the same, then \(E_x = E_{\rho}\cos\phi\), \(E_y = E_{\rho}\sin\phi\), and the above expression is essentially the same as Equation \ref{m0131_eLinAI}. In this case, \(\widetilde{\bf E}\) is linearly polarized. But what if the phases of \(E_x\) and \(E_y\) are different? In particular, let’s consider the following case. Let \(E_x = E_0\), some complex-valued constant, and let \(E_y = +jE_0\), which is \(E_0\) phase-shifted by \(+\pi/2\) radians. With no further math, it is apparent that \(\widetilde{\bf E}_x\) and \(\widetilde{\bf E}_y\) are different only in that one is phase-shifted by \(\pi/2\) radians relative to the other. For the physical (real-valued) fields, this means that \({\bf E}_x\) has maximum magnitude when \({\bf E}_y\) is zero and vice versa. As a result, the direction of \({\bf E}={\bf E}_x+{\bf E}_y\) will rotate in the \(x-y\) plane, as shown in Figure \(\PageIndex{2}\).

Microscopes play a crucial role in scientific research, allowing scientists to observe objects and organisms at the microscopic level. Two common types of microscopes used in laboratories and educational settings are compound microscopes and dissecting microscopes. While both serve the purpose of magnifying objects for observation, they differ in their design, applications, and functionalities.

In the example above, the electric field vector rotates either clockwise or counter-clockwise relative to the direction of propagation. The direction of this rotation can be identified by pointing the thumb of the left hand in the direction of propagation; in this case, the fingers of the left hand curl in the direction of rotation. For this reason, this particular form of circular polarization is known as left circular (or ”left-hand” circular) polarization (LCP). If we instead had chosen \(E_y = -jE_0 = -jE_x\), then the direction of \({\bf E}\) rotates in the opposite direction, giving rise to right circular (or “right-hand” circular) polarization (RCP). These two conditions are illustrated in Figure \(\PageIndex{3}\).

Imaging Filters · BA-FACF-1. DSLR-Astro Conversion Filter ( Baader-ACF 1 ) for Canon EOS 300 improved spectral transmission! · BA-FACF-2. DSLR-Astro Conversion ...

What is linearlypolarized wave

Mar 5, 2024 — Depth of field: Refers to how much of a scene appears acceptably in focus. Depth of field (DOF) describes the distance between the nearest and ...

As anticipated, we see that both \({\bf E}_x\) and \({\bf E}_y\) vary sinusoidally, but are \(\pi/2\) radians out of phase resulting in rotation in the plane perpendicular to the direction of propagation.

Here \(E_x\) is a complex-valued constant representing the magnitude and phase of the wave, and \(\beta\) is the positive real-valued propagation constant. Therefore, this wave is propagating in the \(+\hat{\bf z}\) direction in lossless media. This wave is said to exhibit linear polarization (and “linearly polarized”) because the electric field always points in the same direction, namely \(+\hat{\bf x}\). Now consider the wave

Linear polarization arises when the source of the wave is linearly polarized. A common example is the wave radiated by a straight wire antenna, such as a dipole or a monopole. Linear polarization may also be created by passing a plane wave through a polarizer; this is particularly common at optical frequencies (see “Additional Reading” at the end of this section).

Linear and circular polarization are certainly not the only possibilities. Elliptical polarization results when \(E_x\) and \(E_y\) do not have equal magnitude. Elliptical polarization is typically not an intended condition, but rather is most commonly observed as a degradation in a system that is nominally linearly- or circularly-polarized. For example, most antennas that are said to be “circularly polarized” instead produce circular polarization only in one direction and various degrees of elliptical polarization in all other directions.

Circular polarization

A polarizer or polariser is an optical filter that lets light waves of a specific polarization pass through while blocking light waves of other ...

Dissecting microscopes, also known as stereo microscopes, are widely used for examining larger, opaque specimens that require low magnification. These microscopes are ideal for tasks such as dissecting biological specimens, examining minerals, inspecting circuit boards, and conducting quality control inspections in industries.

\begin{align} \tilde{\mathbf{E}} &=\tilde{\mathbf{E}}_{x}+\tilde{\mathbf{E}}_{y} \nonumber \\ &=\left(\hat{\mathbf{x}} E_{x}+\hat{\mathbf{y}} E_{y}\right) e^{-j \beta z} \label{m0131_eCirc1} \end{align}

The primary differences between compound microscopes and dissecting microscopes lie in their design, magnification capabilities, and intended applications. Compound microscopes are designed for observing small, transparent specimens at high magnification, whereas dissecting microscopes are used for examining larger, opaque specimens at low magnification. Additionally, compound microscopes provide a two-dimensional (2D) view of the specimen, while dissecting microscopes offer a three-dimensional (3D) view. Overall, the choice between a compound and dissecting microscope depends on the specific requirements of the observation task and the nature of the specimen being studied.

\begin{align} \mathbf{E} &=\operatorname{Re}\left\{\widetilde{\mathbf{E}} e^{j \omega t}\right\} \nonumber \\ &=\operatorname{Re}\left\{(\hat{\mathbf{x}}+j \hat{\mathbf{y}}) E_{0} e^{-j \beta z} e^{j \omega t}\right\} \nonumber \\ &=\hat{\mathbf{x}}E_{0} \cos (\omega t-\beta z)+\hat{\mathbf{y}}E_{0} \cos \left(\omega t-\beta z+\frac{\pi}{2}\right) \end{align}

by MR Hatch · Cited by 3 — F n. NA θ. = = (2) where the numerical aperture (NA) is defined by NA = n' sinθ', where θ' is the real axial ray angle in image space, and n and n' refer to ...