When collimation of the primary has been achieved and the Cheshire pattern is correct tighten down the locking nuts and recheck. Do not over-tighten the lock nuts. They should be firm but do not require massive amounts of pressure. I usually feel for them coming into contact with the mirror cell and then add a small amount of pressure.
The scope being collimated in these pictures is a Sky-Watcher 200P with an aperture of 200mm and a focal length of 1000mm (Focal Ratio f 5). This is a common enough fast reflector and the collimation process is essentially the same for any Newtonian telescope. Where there are differences between a fast scope and a slow (high f number) scope I have provided text and pictures to highlight the differences.
If collimation of the primary mirror is required loosen the lock screws off and adjust the primary mirror using its adjuster screws until you see a pattern as per the diagrams and pictures below.
Collimationmeaning
So – get it as good as you can but do not overly worry if there is some small element which isn’t perfect. My own collimation via a Cheshire is always a little ‘off’ – star testing confirms the scope as being spot on so bear this in mind.
The optimum magnification for star testing is at 25x per inch of aperture to start with and then fine tune at 50x per inch if seeing permits – you will need a very stable sky to get maximum magnification.
The Ar+ laser is a gas laser that utilizes a mixture of argon gas and an electric current to generate a powerful beam of light. This process relies on the principle of stimulated emission, where excited argon ions release photons of light under specific conditions.
The hardest stage of collimation is the secondary mirror alignment. This is almost always very time consuming but once done should not need readjustment unless the scope is severely shaken or dropped or the vanes and the secondary are removed for any reason.
Before attempting to collimate the secondary mirror it’s essential to get the mirrors holder central to the tube and the primary mirror. Some scopes allow adjustment of the spider vanes. If your scope has this facility you need to check whether the secondary mirror holder is held perfectly central by the spider vanes.
The Ar+ laser remains a vital tool for electrical engineers and other professionals across various sectors. Its versatility, high power output, and precise wavelength control make it a valuable asset for research, development, and applications ranging from communication to medicine. As technology continues to evolve, the Ar+ laser is poised to play an even greater role in shaping the future of electrical engineering and beyond.
You may wish to carry out a ‘star test’ to verify this and/or to make any fine fine tuning adjustments. Star testing is simple enough to carry out and there is a section below which will explain this and show the most common problems.
Collimationradiology
When collimation is complete you may wish to carry out a star test which will confirm the collimation or show small errors which can be fine tuned out.
Get the star centred in your view using a low power eyepiece. Now use a very high power eyepiece ( or the highest powered you have available) and defocus VERY slightly. You should see a classic Airey disk as shown in the pictures below. Ideally the Airey disk will be perfectly formed for both sides of the perfect focus (Extrafocus and Intrafocus) but in reality most telescopes wont do this perfectly owing to slack within the focus mechanism or atmospheric turbulence but you should see an Airey disk on at least one side of the perfect focus position.
When all three clips are in view (and some scopes may have more clips) and shown at the edge of the secondary mirror with equal space around them this part of the collimation process is complete. Tighten down the tilt adjusters and take a final check.
The final step in collimation is the primary mirror. This is relatively simple to carry out and the cause of most ‘in the field’ collimation errors.
Collimationbinoculars
So – get it as good as you can but do not overly worry if there is some small element which isn’t perfect. My own collimation via a Cheshire is always a little ‘off’ – star testing confirms the scope as being spot on so bear this in mind.
The centre screw adjusts the secondary mirror both up ( away from the primary mirror ) and down ( towards the primary mirror. To adjust this you may have to loosen the screws or Allen keys which control the tilt of the secondary mirror. These are also visible in the picture to the left. Be careful not to apply too much force and go slowly.
Now you should check using a small mirror that the secondary adjustment is more or less equal and that no one screw is causing the mirror to be canted too far over as per the diagrams below.
A simple solution is to use a piece of white card or paper to block the primary mirrors reflections. Simply insert a piece of white paper into the telescope tube between the secondary and the primary mirrors. This will create a view of the secondary as just a white circle. Another tip here is that it’s often quite hard to see whether the secondary is presenting as a circle against the black background of the tube. I insert a piece of coloured card or paper behind the secondary which allows my eyes to more readily detect whether the secondary is appearing as a circle and is centred to the dark circle created by the edge of the focuser.
CollimationX ray
Here's a breakdown of the comparison and justification: **Argon Ion Laser:** * **Advantages:** * High power output for precise cutting of various materials, including metals. * Excellent beam quality for fine details and clean cuts. * **Disadvantages:** * High operating costs. * Requires specialized maintenance. **CO2 Laser:** * **Advantages:** * Lower operating costs compared to Ar+ lasers. * More efficient for cutting non-metallic materials like plastics and wood. * **Disadvantages:** * Lower power output compared to Ar+ lasers, making it less suitable for thick or reflective materials. * Beam quality may not be as precise as Ar+ lasers for fine detail work. **Justification:** If the project involves cutting thin metal sheets with precise details, the Argon Ion Laser would be the preferred choice due to its high power output, excellent beam quality, and suitability for metal cutting. However, if the project involves cutting non-metallic materials like plastics or wood, and cost-effectiveness is a major concern, the CO2 Laser might be a more practical option. Ultimately, the best choice depends on the specific material, desired cutting precision, and budgetary constraints of the project.
Collimationin laser
In the diagram above there is a circle marked in yellow. This is the likely extent of your view if you are using a Cheshire eyepiece at this stage. I personally prefer a collimation cap which provides a slightly wider view of the secondary.
Bear in mind the collimation pattern may be slightly different depending on the f ratio of your scope. For more information see below.
When you are satisfied that the mirror is centred and true as in step 2 AND all the mirror clips from the primary are in view as per step 3 you can now tighten the adjusters down, these need to be firm but do not apply so much force that you strip threads. A standard Allen key is best rather than an Allen headed screwdriver or a multi tool as it will limit the force you can apply. Take care also that you do not apply too much force and cause the spider vanes to bend.
Aligning the secondary mirror to the primary is easily the hardest task. Still using the collimation cap in the focuser you now align the secondary using its tilt adjusters and occasionally a slight amount of rotation on its main centre screw ( you may need to loosen the screw tightly and twist the secondary mirror round by grasping its holder – DO NOT TOUCH THE MIRROR ITSELF ) to get the secondary centred onto the primary. This process is covered in the pictures below.
To collimate the telescope it should be aimed towards a bright but not glaring surface such as a well lit pale painted wall or fabric in order to get a good image in the telescope and the Chesire should be arranged so that its shiny angled surface gets a good light. Cheshire @ Amazon
Tips before you start ….. Rule 1 – Before starting collimation don’t assume that anything is out of kilter and check each element before adjusting anything. About 90% of collimation errors are down solely to the primary mirror so don’t jump in and start meddling with the secondary unless you are sure that there is a problem. Each stage of this guide will show you how to check the various elements – only if they are out of alignment will you need to make adjustments.
When this step is completed and all of the alignment patterns shown in this guide are true then the telescope is collimated to within the limits of what you can achieve with a Cheshire and you should find the telescope is perfectly well collimated for use.
Rule 3 – Make sure you have budgeted for enough time. Collimation can be a very time intensive process for a beginner. It can be carried out over successive sessions if you need to but don’t plan on collimating on a night when you want to be observing. It will lead to a rush job and frustration – TAKE YOUR TIME and you will be rewarded with good collimation and better viewing through your telescope.
Rule 5 – Whenever you are working on a telescope ALWAYS work with the telescope tube in a horizontal position. If you drop things into the tube you don’t want them to impact on the primary mirror. I also wear cotton gloves when I am working to make sure I don’t damage anything with sweat from my hands.
To star test you will need a bright star and good seeing conditions. Polaris is the best star to test on but almost any bright star will do. You will need your telescope to have cooled down to the ambient temperature and also to be away from obstructions such as houses which may cause air thermals.
The second method for aligning the mirror holder is a little more complex but more accurate and easier once the initial work is done. Cut a piece of card out which is the same diameter as the telescope tube and drill a small hole in its centre. To find centre on the circular piece of card fold the card into quarters. The point where the folds cross is the centre. Now look through the hole and the central screw on the secondary mirror holder should be exactly underneath. If it isn’t adjust the spider vanes until it is. This provides a simple and reliable method of getting the mirror holder central and once you have made the piece of card future centering of the vanes will be easier. To adjust the vanes you will need to slacken the screws and then slowly tighten them in turn to pull the mirror holder to the centre.
This guide may look scary – if you take it one step at a time its not that hard. In order to cover off all of the issues the guide is somewhat larger than some others on the web – many guides omit various details which can lead to confusion and frustration in the beginner.
Task: Imagine you are an engineer working on a project that requires precise material cutting. You need to choose between an Argon Ion Laser and a CO2 Laser for this task. Compare the advantages and disadvantages of each laser type in terms of material processing capabilities and provide a well-reasoned justification for your choice.
Be aware that in UK skies atmopsheric turbulence will be very often the pattern you will see. Unfortunately the typical turbulence pattern is very similar to the pattern you will see with a badly damaged mirror. Unless you have reason to believe the mirror IS damaged then there is no need to panic.
To accurately collimate with this guide you will need a Cheshire collimator and a collimation cap. My own collimation cap is made from a focuser blanking cover with a small hole drilled through the exact centre. You can make a collimation cap from a 35mm film container or buy them ready made.
This guide will take you through the various steps towards perfect collimation. I have included both diagrams to show you the ideal as well as pictures showing how it will actually look as beginners are often confused between the idealised views of a well collimated telescope and the views they are seeing with their own equipment.
For this stage you will need the Cheshire collimator. Insert this into the focuser and take a look through the collimator. You should see a pattern similar to the one shown below right – this is from a telescope that is in collimation.
Rule 4 – Do not over-tighten nuts and adjusters. They need to be firm and tight – they DON’T need to be tightened until the threads pop.
Take care when using the adjuster screws that you do not allow the mirror to come too far forward on adjustment as the screws may disengage and also take care that the collimation screws and lock screws aren’t tightened down to a point which may cause the primary mirror to become ‘pinched’ or distorted. They should be finger tight only.
Collimationin surveying
When adjusting your telescope bear this in mind and try not to become obsessed with having every element exactly perfect. Many things will ultimately upset the ‘perfect’ collimation. These include focuser ‘slop’ – this is the looseness of all but the very best quality focusers, slight imperfections in the shape of the secondary mirror, temperature variations and even the anglular position of the telescope.
Fast telescopes are typically of around f5 to f3 or even faster. You can calculate the focal ratio of your own telescope by the simply dividing the focal length by the diameter of the primary mirror. The Sky-Watcher 200P has a focal length of 1000mm and a primary mirror diameter of 200mm so 1000 divided by 200 = 5 ( focal ratio ). Slow telescopes are usually at f6 – f7 or slower.
Collimationlens
You will also need to rotate the mirror until it presents as good a circle in the focuser as possible and adjust the tilt screws to to achieve a good circular shape on the secondary.
Primary mirrors are quite heavy and most telescope tubes are quite light. As a result a telescope tube will flex in normal usage and this alone will upset collimation.
Collimationtelescope
If the secondary is not centred under the eyepiece you will need to adjust it using the centre screw of the secondary holder.
You should note that fast scopes of f5 and above are less tolerant of collimation errors and they also show slightly offset collimation patterns. These are shown below as a guide.
A note on spider vanes in the view………… When collimating the spider vanes, apart from the inistial stage of making sure they are holding the secondary mirror central, are not relevant to the collimation procedure. Ignore them – you should only be looking at the Cheshires cross hairs and making sure that the cross hairs intersect the primary mirror centre spot.
The world of electrical engineering is filled with innovative tools and technologies, each playing a crucial role in pushing the boundaries of what's possible. Among these powerful tools stands the Argon Ion Laser (Ar+ laser), a versatile and highly efficient light source that finds application across a wide range of disciplines.
At the rear of the telescope you will find three pairs of screws. These are the primary mirror tilt adjusters and their respective lock nuts.
The tilt adjusters can be set quite tight but be careful not to apply too much force and bend the spider vanes. As with the previous step its best to have the telescope horizontal during this step in case an Allen key is dropped into the tube.
Once the primary mirror clips are shown reflected in the secondary and the tilt screws have been tightened take a final check using the procedures in stage 2 that the secondary still shows as centred and circular. If the secondary has shifted then you will need to realign using the procedures in stage 2 and then run through the procedures in stage 3 again. Its not uncommon for some rotation error to creep into the mirrors position while the tilt screws are adjusted. Take your time, be patient and continuously go back over your work and make sure all is well at each stage before continuing.
First remove the coloured card and the white ‘baffle’ card in the telescope tube. Now look into the collimation cap and using the tilt screws get all of the primary mirrors retaining clips into view and at the edge of the secondary mirror. IGNORE ALL OTHER VISUAL INFORMATION ! All you are trying to do at this stage is get the secondary mirror centred on the primary mirror.
In the fast scope patterns above and below the circles are in fact concentric and true (ie. totally circular) but the offset of the secondary mirror creates an illusion that the reflection is elliptical and/or off centre. These differences are shown with diagram plus an actual photograph of a fast scope collimation view to give you an idea what the final view through the Cheshire should look like.
The easiest method to align the secondary mirror is with either a collimation cap or a sight tube. With my Sky-Watcher 200P I find a collimation cap is the better solution as a sight tube or my Cheshire do not allow me to see the very edges of the secondary mirror through them.
It may be that that the pattern is offset and will show the cross hairs as being adrift from the central circle created by the Primary Mirrors centre spot and that the centre spots are adrift. If this is so then you will need to adjust the primary mirror.
If you are not seeing an Airey disk this then there are several reasons why. This may be due to faulty collimation or other conditions which may not be correctable.
This is shown below. You are advised to have the telescope tube near the horizontal position while you carry out this work in order to ensure that if there is an accident the secondary doesn’t fall down the tube and into the primary mirror. Keep a hand holding or supporting the secondary mirror holder without touching the mirror surface itself. Proceed with great care and caution and take your time. The adjuster screw is quite coarse and the mirror will move quite a lot with each turn. Be careful not to loosen the screw too much which will cause the secondary to disengage from its holder and fall off.
Rule 2 – Make sure you have all of the tools you require ready to hand. Some telescopes will require Allen keys and a screwdriver. You don’t want to be looking for tools when you halfway through collimation.
I have not covered collimation with a laser because my own experience has been lasers seem to create more problems than they solve as they also require collimation which isn’t always possible with some low cost lasers. Lasers generally only work well in telescopes which have a high quality focuser with minimal ‘slop’. The average mass produced telescope very often has a focuser that is too imprecise to make use of a laser.
Now move the mirror up or down the tube using the central adjusting screw on the mirror holder until you have the secondary mirror centred.
Note: Some telescope manufacturers (Sky-Watcher for instance) cover the collimation adjusters with a steel plate. This will need to be removed before collimation can proceed.
You can now proceed to the second stage of the secondary alignment which is aligning the secondary to the primary mirror.
There are two methods to accomplish getting the mirror holder central to the tube. The first is relatively simply which is to measure the distance between the tube and the secondary mirror holder along each of the vanes. The distance should be identical for each vane. If the vanes are not equal than adjust them using the vanes attachment / adjustment screws. The cross head on the central screw makes an ideal reference point.
Even a turbulent atmosphere pattern will allow you to see whether the circles are concentric or whether they are off centred and non-concentric.