Microscope Objective Specifications - objective on a microscope
AutocollimatorThorlabs
Electronic Autocollimator is a precision USB 2.0 device combining the functionality of autocollimator and alignment telescope - the ideal instrument for optical measurements of minute optical surfaces deviations. It provides a 3-in-1 instrument: electronic autocollimator, focusing telescope and infinite conjugate collimator. The system is capable to measure minute angular displacements of various optical setups.
In optical engineering, an objective is an optical element that gathers light from an object being observed and focuses the light rays from it to produce a real image of the object. Objectives can be a single lens or mirror, or combinations of several optical elements. They are used in microscopes, binoculars, telescopes, cameras, slide projectors, CD players and many other optical instruments. Objectives are also called object lenses, object glasses, or objective glasses.
Autocollimatorfor sale
All these types of objectives will exhibit some spherical aberration. While the center of the image will be in focus, the edges will be slightly blurry. When this aberration is corrected, the objective is called a "plan" objective, and has a flat image across the field of view.
AutocollimatorPDF
Some microscopes use an oil-immersion or water-immersion lens, which can have magnification greater than 100, and numerical aperture greater than 1. These objectives are specially designed for use with refractive index matching oil or water, which must fill the gap between the front element and the object. These lenses give greater resolution at high magnification. Numerical apertures as high as 1.6 can be achieved with oil immersion.[2]
Instead of finite tube lengths, modern microscopes are often designed to use infinity correction instead, a technique in microscopy whereby the light coming out of the objective lens is focused at infinity.[1] This is denoted on the objective with the infinity symbol (∞).
A typical microscope has three or four objective lenses with different magnifications, screwed into a circular "nosepiece" which may be rotated to select the required lens. These lenses are often color coded for easier use. The least powerful lens is called the scanning objective lens, and is typically a 4× objective. The second lens is referred to as the small objective lens and is typically a 10× lens. The most powerful lens out of the three is referred to as the large objective lens and is typically 40–100×.
Autocollimatortelescope
In addition to oxide glasses, fluorite lenses are often used in specialty applications. These fluorite or semi-apochromat objectives deal with color better than achromatic objectives. To reduce aberration even further, more complex designs such as apochromat and superachromat objectives are also used.
One of the most important properties of microscope objectives is their magnification. The magnification typically ranges from 4× to 100×. It is combined with the magnification of the eyepiece to determine the overall magnification of the microscope; a 4× objective with a 10× eyepiece produces an image that is 40 times the size of the object.
The distinction between objectives designed for use with or without cover slides is important for high numerical aperture (high magnification) lenses, but makes little difference for low magnification objectives.
The traditional screw thread used to attach the objective to the microscope was standardized by the Royal Microscopical Society in 1858.[3] It was based on the British Standard Whitworth, with a 0.8 inch diameter and 36 threads per inch. This "RMS thread" or "society thread" is still in common use today. Alternatively, some objective manufacturers use designs based on ISO metric screw thread such as M26 × 0.75 and M25 × 0.75.
Autocollimatorworking principle
The objective lens of a microscope is the one at the bottom near the sample. At its simplest, it is a very high-powered magnifying glass, with very short focal length. This is brought very close to the specimen being examined so that the light from the specimen comes to a focus inside the microscope tube. The objective itself is usually a cylinder containing one or more lenses that are typically made of glass; its function is to collect light from the sample.
Autocollimatorformula
The system offers portable, compact and accurate beam alignment solution. Our precision electronic autocollimator has built in adjustment features, such as leveling bubble, adjustment pan tilt knobs, enhancing the unprecedented alignment procedure, also with a built-in alignment laser.
The working distance (sometimes abbreviated WD) is the distance between the sample and the objective. As magnification increases, working distances generally shrinks. When space is needed, special long working distance objectives can be used.
Historically, microscopes were nearly universally designed with a finite mechanical tube length, which is the distance the light traveled in the microscope from the objective to the eyepiece. The Royal Microscopical Society standard is 160 millimeters, whereas Leitz often used 170 millimeters. 180 millimeter tube length objectives are also fairly common. Using an objective and microscope that were designed for different tube lengths will result in spherical aberration.
Numerical aperture for microscope lenses typically ranges from 0.10 to 1.25, corresponding to focal lengths of about 40 mm to 2 mm, respectively.
Camera lenses (usually referred to as "photographic objectives" instead of simply "objectives"[4]) need to cover a large focal plane so are made up of a number of optical lens elements to correct optical aberrations. Image projectors (such as video, movie, and slide projectors) use objective lenses that simply reverse the function of a camera lens, with lenses designed to cover a large image plane and project it at a distance onto another surface.[5]
System includes:Electronic Autocollimator unit with USB 2.0 CCD camera, mounted on base with attached power supply, Corner Cube Retroreflector for initial alignment, software on CD.Minimum software and hardware requirements:Pentium IV, 2.4 Ghz, 512MB RAM, 10MB HDD, 64MB 24 bit VGA card, 1 x USB 2.0, CD RP<. Win XP/7 (32 bit).
Particularly in biological applications, samples are usually observed under a glass cover slip, which introduces distortions to the image. Objectives which are designed to be used with such cover slips will correct for these distortions, and typically have the thickness of the cover slip they are designed to work with written on the side of the objective (typically 0.17 mm).
In a telescope the objective is the lens at the front end of a refracting telescope (such as binoculars or telescopic sights) or the image-forming primary mirror of a reflecting or catadioptric telescope. A telescope's light-gathering power and angular resolution are both directly related to the diameter (or "aperture") of its objective lens or mirror. The larger the objective, the brighter the objects will appear and the more detail it can resolve.
Autocollimatorprice
Measurements of: Mirror angleStraightness of linear stagesCharacterization of rotation angleWedge, prism and polygon anglesReflecting surface parallelismSurface flatnessAlignment of optical setupsMachine alignmentThermal stabilityVibration analysis
Basic glass lenses will typically result in significant and unacceptable chromatic aberration. Therefore, most objectives have some kind of correction to allow multiple colors to focus at the same point. The easiest correction is an achromatic lens, which uses a combination of crown glass and flint glass to bring two colors into focus. Achromatic objectives are a typical standard design.