Focal Length of a Convex Lens Using u-v Method - focal length formula convex lens
Sometimes also the pulse shape is needed, see App 022 covering laser pulse shape measurement or dual detector sphere for laser power and laser waveform measurement. The optometer can also take the measurement time into account and integrate the laser power over time, showing directly the resulting energy/laser dose (in J).
Gigahertz-Optik offers standard sphere systems as well as highly flexible customized setups. This leads to various geometries as well as diode combinations being possible. See our Modular Integrating Sphere Concept for individual Laser Power Meters/Sphere Systems for further details here.
HV-KIT-ESD
The minimum and maximum power that can be measured are determined by the combination of detector and optometer being used. Our products usually cover a very large power range from few nW up to kW due to our multi-gain range transimpedance amplifiers
This setup is the most basic one. It consists of a wired photodiode inside a metal housing connected to an optometer. Due to the high linearity of photodiodes, this setup provides precise reading of low as well as medium power lasers.
Here you can get a first overview of our products Radiometeres for Laser Radiation/Laser Power Meters. Also our Spectroradiometers for Radiometry/Spectrometer for Laser Power Measurements can be combined with integrating spheres for spectral laser power measurements. Please contact us for further information.
The Handi-Vac-2 has an improved tip designed for better lifting capacity utilizing larger, non-marking vacuum cups. This new tip also enhances functionality and improves accuracy when picking and placing parts. One static-dissipative cup included. The entire vacuum tool is ESD-safe.
Pure photodiode detectors can be used for CW, pulse energy as well as pulse shape analysis (rise-time of the diode must be considered).
Reynolds Handi-Vac
For any kind of radiometric laser power measurement, the calibration plays a key role for the precision of the final result. In other words, a low calibration uncertainty which you can trust is important. In that respect we offer laser power calibrations certified in our DAkkS ISO 17025 accredited calibration and testing laboratory. This means highest standards according to the ISO 17025 are applied to the processes to ensure reliability and traceability of our calibrations. All calibrations are directly traceable to the PTB, the German NMI, or comparable NMIs. Our calibration laboratory covers the wavelength range from 200 nm – 2500 nm.
For this concept/measurement setup the flexibility is much larger, since the range of sphere diameters we can offer ranges from 8 mm to 1 m. Hence it is possible to design measurement ports (integrating sphere entrance port) accordingly and large laser beam diameters or highly divergent beams can be measured if needed. Optical power levels can be adjusted more easily by a combination of optical density filters and the sphere diameter (attenuation by larger spheres). Additionally, the dynamic range can be extended by using multiple photodiodes in one integrating sphere for different optical power ranges. In total this approach permits maximum laser powers of more than 100W to be still measured correctly.
Handi vactweezer
By clicking Submit, you acknowledge that you may be contacted by Fisher Scientific in regards to the feedback you have provided in this form. We will not share your information for any other purposes. All contact information provided shall also be maintained in accordance with our Privacy Policy.
Lasers are widely used in many different applications today. Optical communications, laser printing, material processing, distance measurement (LiDAR), medicine and mass spectrometry to name a few.
However, when measuring short pulses (ns range), larger integrating sphere lead to pulse stretching due to the light’s propagation time inside the sphere resulting from multiple reflections. Hence for pulse shape analysis, only small spheres can be used or the sphere diameter needs to be adjusted to the expected pulse length. Also dual detector setups are possible to address the specific needs. Here we can offer our support and experience depending on the laser parameter and provide you with the best solution for your application. See for instance our 16 mm ISD-1.6-SP innovative dual sensor integrating sphere which is among others used for lidar laser characterization.
The Fisher Scientific Encompass Program offers items which are not part of our distribution portfolio. These products typically do not have pictures or detailed descriptions. However, we are committed to improving your shopping experience. Please use the form below to provide feedback related to the content on this product.
Any incoming signal from the photodiode is stretched in time in order to fit to the rise-time of the optometer’s built-in transimpedance amplifier.
I have read the data privacy declaration. I consent to my details and data being collected and stored electronically for the purpose of responding. Note: You can revoke your consent at any time for the future.
Since the diode can only measure optical radiation or light which impinges on its active area, the laser spot on the diode must be smaller compared to the dimensions of the photodiode’s active area in order to measure its total power accurately. This limits the laser spot diameter to a certain extent (typically a few mm). Furthermore, the maximum power is limited by the photodiode’s responsivity, linearity (saturation) and the optometer's maximum input current (typical max. values are in the range of a few mW). Of course, optical density filters (ND filters) can be used to a certain extend.
handi-vac vacuum pen
This well-established measurement concept works for CW-sources as well as pulsed sources. For pulsed sources, the average power is normally measured. Therefore, the integration time and the pulse frequencies must be matched.
handi-vac bags
We keep science moving forward by offering over 2.5 million products and extensive support services to the research, production, healthcare, and science education markets. Count on us for an unrivaled selection of lab, life sciences, safety, and facility management supplies—including chemicals, equipment, instruments, diagnostics, and much more—along with exceptional customer care from an industry-leading team that’s proud to be part of Thermo Fisher Scientific.
The photodiode is converting the incoming laser radiation into an electrical current which is read out by the optometer. With the help of a radiometric calibration (e.g. by the ISO 17025 accredited calibration laboratory of Gigahertz-Optik) the optometer will show the resulting optical power (in W) at the desired wavelength.
With the optometer classical laser power meter P-9710 and its successor the modern touchscreen laser power meter P-21, Gigahertz-Optik also offers a precise optometer to measure incoming pulse energy. This measurement is using the principle of the so-called pulse-stretching method.
You can add products to the watchlist and compare them with one another or send us an inquiry. There are watchlist symbols on product pages and product tables for this purpose.
During this stretching, the energy remains constant (area A1 = A2) but area A2 can be much higher sampled which results in a more precise measurement compared to area A1. The final results show the laser energy (in J) on the detector during the measurement. This offers the ability to precisely measure pulse energies of pulse chains as well as single pulses down to the ns range. For single pulses a trigger possibility is offered.
This detector concept is built by adding a photodiode onto a hollow sphere with highly reflective inner coating, a so-called integrating sphere. This setup is then calibrated in our ISO 17025 calibration laboratory. In order to measure optical power accurately, all optical radiation must be coupled into the integrating sphere through its entrance port.
For many of these applications, the power (peak power, average power, pulse shape) or energy as well as the stability of the laser being used must be measured in order to control for instance the safety according to safety standards like Artificial Optical Radiation Directive 2006/25/EC or laser classification according to EN 60825-1 classification. For such kind of measurements, the combination of a photodiode-based sensor and an electronic read-out device (Optometer) can be used.