The OSBM procedure comprises operating a BF microscope under Köhler illumination (ς = 0.1 to 0.2), capturing a z-stack of images of unstained samples, and applying the following digital pipeline to images (Fig. 1D). First, large spatial structures are filtered out from raw BF images. Second, the z-gradient is computed by performing pairwise image subtraction, followed by Gaussian smoothing. Finally, a filter that highlights small, bright features (such as white top hat) is applied. Fig. 1D shows how OSBM works, applied to a living sample of the filamentous fungus Trichoderma atroviride. To validate OSBM, we compare resulting images with true optical sectioning (12) counterparts, using light-sheet fluorescence microscopy (LSFM). The background-free, axially localized spots produced by OSBM show good overlap with those from LSFM (Fig. 1E).

Bright fieldmicroscope

Oct 29, 2024 — Startup Steroid is an expertly designed platform that connects modern-day startup founders and investors. Its structured deal flow ...

Bright field illuminationpdf

To demonstrate 3D imaging using OSBM, we first consider a living filamentous network (T. atroviride), where scattering structures are well-localized and mostly distant from each other (compared to filament diameter). Application of OSBM results in a dramatic transition from blurred (original BF) to crisp (final) images (Fig. 2A). Excellent agreement is found between OSBM and LSFM (Fig. 2 A and B), enabling proper 3D rendering of hyphal structures (Fig. 2C and Movie S1). As OSBM does not use a narrowly focused laser beam, sharp images throughout the entire field of view are produced, thus complementing LSFM.

Image

Articles from Proceedings of the National Academy of Sciences of the United States of America are provided here courtesy of National Academy of Sciences

Bright fieldmicroscope principle

Ready-to-use Cyan Fluorescent Protein (CFP) Adenovirus. enhanced Cyan Fluorescent Protein (CFP) adenovirus 1766 Ad-CFP Ad-CMV-CFP.

So when your screen says it has a 3H coating it doesn't actually tell you what material it is made of - it simply tells you whether or not it is ...

Secure .gov websites use HTTPS A lock ( Lock Locked padlock icon ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

Bright field illuminationapp

This article contains supporting information online at https://www.pnas.org/lookup/suppl/doi:10.1073/pnas.2122937119/-/DCSupplemental.

Official websites use .gov A .gov website belongs to an official government organization in the United States.

Image

Image

OSBM imaging of onion skin and plant root. (A) OSBM applied to a layer of onion epidermis, showing MIP images along x–y (Left), y–z, and x–z (Center). y–z and x–z images correspond to the white boxes shown in the x–y projection. BF maximum intensity projection images are shown (Right) for comparison. (B) Imaging of an unlabeled, untreated A. thaliana root sample. Field of view for 3D rendering, 1,495 × 1,495 × 1,008 μm3.

48 Aberrational synonyms. What are another words for Aberrational? Aberrant, straying, errant, aberrative. Full list of synonyms for Aberrational is here.

Sep 17, 2022 — After passing through the half-wave plate, the linearly polarized light is still linearly polarized, but the vibrational surface of the combined ...

In BF with Köhler illumination (Fig. 1A), decreasing the numerical aperture (NA) of the condenser, establishing the coherent regime (NAcondenser/NAobjective = ς → 0) (2, 10), results in high-contrast imaging of phase specimens and strong contrast inversion upon axial scanning through focus. This behavior is evident in the phase point spread function (pPSF) (8, 9) (Fig. 1B); Weber contrast of the central spot changes from positive to negative and is zero at exact focus (z = 0). However, by introducing an amount of defocus close to the depth of field we find that BF imaging is in good correspondence with a ground truth (Fig. 1C and SI Appendix), suggesting accurate sample information can be extracted from BF.

An inverse-imaging problem is therefore identified, where BF image stacks featuring axial intensity gradients constitute the output signal. We reconstruct the input 3D object by finding the axial location of the source of these gradients, using standard digital processing filters (11). The set of points thus found corresponds to the scattering structures that compose the specimen.

Author contributions: B.G.-M. designed research, performed research, contributed new reagents/analytic tools, analyzed data, wrote the paper, and received funds to perform research.

Bright fieldmicroscope application

Broadly, the reconstruction of an input object from the corresponding output image constitutes a well-known inverse problem in microscopy. Deconvolution, a standard method that addresses this problem, typically analyzes images in the Fourier domain and has been successfully applied to BF in 2D (8, 9). Here, we introduce optical sectioning in bright-field microscopy (OSBM), a 3D image reconstruction method based on analyzing in real space high-contrast BF images of phase objects.

Bright fieldmicroscope parts and functions

Concave mirrors are used where we want to converge light and convex mirrors are used where we want to diverge the light. The principal focus of convex mirrors ...

Image stacks and computer code used to analyze images have been deposited in Zenodo (https://zenodo.org/record/5931508#.YizNqzVMFPY). All other data are included in the manuscript and/or supporting information.

Meningeal tissue was treated using CLARITY (14); optical microscopy and digital image processing were performed using a home-made setup (15) and Fiji (16), respectively.

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Shop for the Roland TM-2 Drum Trigger Module in and receive free shipping and guaranteed lowest price.

Altogether, OSBM excels at imaging sample boundaries of optically thin objects and structures with low axial spatial density. As a digital extension of traditional BF microscopy and complement to fluorescence microscopy techniques, OSBM offers a simple, direct, and model-free alternative for bioimaging in 3D.

Bright-field microscope Diagram

Competing interest statement: B.G.-M. is inventor on USPTO patent application 17/550,797 submitted by Instituto Potosino de Investigación Científica y Tecnológica A.C. that covers “System and method for three-dimensional imaging of unstained samples using bright field microscopy.”

We applied OSBM to visualize untreated samples with different optical transmissivity. A layer of onion epidermal cells immersed in water is mostly transparent, enabling optimal visualization in BF. Accordingly, we observe the characteristic onion cell shapes in both longitudinal (x–z) and transversal (y–z) views (Fig. 3A), where periclinal wall curvature is readily identified. A comparison OSBM–LSFM for onion cells (Movie S3) shows good match and consistent cell wall imaging by OSBM in places where fluorescence is absent, emphasizing complementarity between OBSM and LSFM. As onion cell wall thickness is ∼6 μm (13), OSBM can detect isolated semiplanar scattering structures only a few micrometers thick (using a 10× objective lens). Finally, we consider seedlings of Arabidopsis thaliana, which present significant optical opacity. By comparing with LSFM, OSBM shows appropriate 3D imaging of thin root hairs and the surface of the thick root that faces the objective lens (Fig. 3B and Movie S4). For optically thick biological samples, using infrared light should help improve OSBM imaging (SI Appendix).

This work was supported by Consejo Nacional de Ciencia y Tecnología (Mexico) Grants IFC-2015-2/1144 and INFR-2018-295138 to B.G.-M. I thank Sergio Casas-Flores, Mitzuko Dautt, Miguel Condés-Lara, and Guadalupe Martínez-Lorenzana for gifts of samples; Ana Iris Peña-Maldonado for help with scanning electron microscopy; the Nanoscience and Nanotechnology Research National Laboratory (LINAN) at Instituto Potosino de Investigación Científica y Tecnológica for access to their facilities; and Isaac Carrillo-Acuña for assistance with fungal sample preparations.

Principle of OSBM. (A) Schematic of our BF microscopy setup, showing illumination and scattered light rays (gray and green, respectively). Lenses are depicted as double arrows. (B) Image of the BF pPSF, computed using equation 1 in reference 9 with: λ = 450 nm, n = 1.0, NAobjective = 0.1; field of view (x–z): 90 × 404 μm2. (C) BF and scanning electron microscopy (SEM) images of a dry filamentous fungus sample (T. atroviride). BF image was acquired at z = −6.0 μm. (Scale bar: 100 μm.) (D) Digital pipeline of OSBM (round boxes) and resulting images for a living T. atroviride sample. (E) Overlay of the “final image” of OSBM shown in D (red) with the corresponding LSFM image (green).

OSBM imaging for test samples and comparison with LSFM. (A–C) Fungal sample. (D–F) Clarified blood vessel sample. (A and D) Maximum intensity projection (MIP) images for BF, OSBM, and LSFM. (B and E) Merged images of OSBM (red) and LSFM (green) shown in A and D, respectively. (C and F) Three-dimensional images obtained from the corresponding OBSM optical sections. Field of view for C and F, 1,495 × 1,495 × 1,016 μm3 and 1,495 × 1,495 × 1,128 μm3, respectively.

The bright-field (BF) optical microscope is a traditional bioimaging tool that has been recently tested for depth discrimination during evaluation of specimen morphology; however, existing approaches require dedicated instrumentation or extensive computer modeling. We report a direct method for three-dimensional (3D) imaging in BF microscopy, applicable to label-free samples, where we use Köhler illumination in the coherent regime and conventional digital image processing filters to achieve optical sectioning. By visualizing fungal, animal tissue, and plant samples and comparing with light-sheet fluorescence microscopy imaging, we demonstrate the accuracy and applicability of the method, showing how the standard microscope is an effective 3D imaging device.

Hydrophobic Window repels oils (oleophobicity) and other liquids (hydrophobicity), making it easier to clean optics and ensuring maximum transmission of ...

The classic bright-field (BF) microscope is an indispensable tool in any biological laboratory, routinely used to evaluate cellular or tissular morphology in stained two-dimensional (2D) samples. In the absence of staining, however, BF images of phase objects display little contrast (1). Several imaging modalities address this limitation, from early alternatives now widespread (e.g., Zernike phase contrast and differential interference contrast) (2) to recent advancements that allow quantitative measurement of the complex sample field (e.g., quantitative phase contrast) (3).

Darkfieldmicroscope

Image stacks and computer code used to analyze images have been deposited in Zenodo (https://zenodo.org/record/5931508#.YizNqzVMFPY). All other data are included in the manuscript and/or supporting information.

by B Wu · 2009 · Cited by 93 — EGFP and EYFP are good examples of fluorescent proteins well described by the single-brightness-state model. To study heterointeraction, the emission of the two ...

Despite drawbacks, BF remains attractive because it is a simple, fast, and inexpensive microscopy method, where photodamage and phototoxicity is much reduced compared to fluorescence microscopy. Three-dimensional (3D) imaging in BF has been obtained by processing multiple images acquired from different angles into a single reconstruction (4, 5) or using deep learning to predict 3D fluorescence signal (6, 7), although specialized instrumentation or extensive computer modeling is required.

This open access article is distributed under Creative Commons Attribution-NonCommercial-NoDerivatives License 4.0 (CC BY-NC-ND).

One limitation for OSBM arises from contrast inversion of the pPSF. When two scattering structures are axially contiguous, they produce overlapped transition regions in the BF image, hindering proper object localization. This effect is expected to be marked for strongly scattering objects such as filaments (scattering intensity I ∝ r3, where r is radius of the filament) compared to point-like structures (I ∝ r6). In our experiments, we estimate that axial distances below 70 μm (40 μm) between scattering structures cause improper imaging for hyphal (meningeal tissue) samples.

Next, we tested a sample with a continuous scattering structure, an optically cleared blood vessel (Fig. 2D). The OSBM image of this tissue is pointillistic, where the collective of points provides sharp localization of tissue boundary and structures such as pleats. A comparison between OSBM and LSFM images shows excellent correspondence in overall sample morphology (Fig. 2 D and E). A 3D reconstruction is shown in Fig. 2F and Movie S2.

Notch Filter Calculator ... The filter topology here is the Fliege topology. I have found this to be the most stable and most easily tuned notch filter topology.