The automated ultra-precision afocal unit is available as upgrade for afocal samples. With different autocollimator lenses for the afocal unit measurement in different wavelength ranges can be executed.

The devices ImageMaster® HR 2 and Universal provide an outstanding level of accuracy and flexibility when testing the MTF (modulation transfer function). The equipment is modular and upgradeable to allow for custom configuration as test requirements change. The instrument can be configured for testing optical systems with the object at infinity or object and image at finite conjugates. The accuracy of the measurement is traceable to international standards.

This procedure requires a comparatively large number of measurement points with accurately known object angles and field positions. For this reason ImageMaster® instruments with dedicated distortion measurement option feature a high precision angular encoder for the object generator (accuracy 5 arcsec) and a high precision linear encoder for the image field stage (accuracy 0.2 μm). This way, the EFL is calculated as an absolute quantity, not depending on calibration parameters.

The ImageMaster® HR fulfils the high customer requirements for accuracy and flexibility in the measurement of image quality.

Field of view

... optic in place when aligning that optic. That way you can easily tighten and loosen it as you fix the alignment of the optical component. Then when you have ...

Many optical systems such as lenses and camera modules are used in a wide temperature range and must consistently maintain their full functionality and performance across varying temperatures. Athermal designs should minimize the thermal influences on opto-mechanical parameters.

The modulation transfer function varies not only related to the spatial frequency but also with the position in the field of view. The MTF measurement along the axis of symmetry of the optical system is known as on-axis measurement.

I hereby subscribe to receive the TRIOPTICS email newsletter that contains regular information about new products and events. My personal data will be used exclusively in accordance with the TRIOPTICS privacy policy and I can revoke my consent to this at any time with future effect, e.g. via the unsubscribe link in the newsletter.

Older objectives often have the focal length (lens-to-image distance) engraved on the barrel, which is a measure of the magnification. In modern microscopes, ...

The grids shown are actually no longer used in order to measure the MTF. Modern MTF-Testers like the ImageMaster® use a single illuminated slit on opaque background as the object. From a mathematical point of view a single slit can be regarded as the sum over all spatial frequencies (Fourier synthesis). All frequencies contribute with the same amplitude (=1) to this slit not taking the finite slit width into account for this description. This single slit will be imaged into the image plane of the sample. Due to diffraction and aberrations there will be no perfect slit image in this plane, instead the slit image is broadened. It represents the so called Line Spread Function (LSF). On the basis of Fourier analysis the contribution of each spatial frequency to the LSF can be calculated. Actually the amplitude of each spatial frequency is equal to the contrast at this frequency. The Fourier analysis of the Lines Spread Function corresponds to the MTF of the sample. Taking a single image of the LSF unveils the complete MTF. Alternatively it is also possible to use a cross (i.e. two perpendicular slits) for the target. This enables the ImageMaster® to measure the MTF in two image directions simultaneously provided a CCD camera is used for the image analyzer. And finally a pinhole target can be used as the object, too. The image of a pinhole target is called Point Spread Function. This function contains the complete MTF information in all image directions. The basic terms and mathematical relations used for MTF are described in the ISO 9334 standard.

ImageMaster® HR 2ImageMaster® HR MAX ImageMaster® HR MAXImageMaster® Universal ImageMaster® HR TempControlMeasurement service (ImageMaster® HR TempControl)

In addition to determination of the MTF, the key measurement parameter is the change in both the flange focal length and effective focal length when the temperature changes.

14 Depth of Field. SNAPSHOT. Defining Depth of Field: ... The three factors affecting DoF explained: ... Depth of Field (DoF) refers to the distance between the ...

Progressive Scan. A scanning method in which the sensor scans each lines of the field sequentially (rows 1, 2, 3, 4..., etc.). All image data is recorded in a ...

To completely characterize the imaging performance of an optical system, the MTF must be measured at different positions within the field of view. The MTF measurement within the field of view is known as off-axis measurement. In order to achieve an off-axis measurement, the target is moved in the field of view at the desired object position and the image analyzer to the corresponding image position.

Many years of experience with a wide range of customer requirements have been incorporated into the development of the ImageMaster® HR 2. The improvements achieved result in an extended usability for customers, high repeatability, ease of operation, modern design and a clean look-and-feel.

In addition to military and aerospace applications, cameras are also being used in the automotive industry as safety-critical systems whose properties must be tested and ensured across a broad temperature span.

ImageJMTF

In general, the image quality of lenses can be affected by temperature influences on the optical components and mounting materials. Crucial lens parameters such as effective focal length and flange focal length can be temperature-dependent and have an impact on the camera’s focusing function.

Proximity sensors in vehicles are an important feature for driver assistance systems. They operate in the short infrared spectrum (SWIR), so a suitable measurement system is required to test the image quality. Moreover, measurement in SWIR spectrum becomes more important, for smartphone lenses. With a measurement accuracy of ±0.03 MTF and reproducibility of ±0.01 MTF the system meets the highest requirements even for small apertures.

Measuring the imaging properties of optical systems, the user of the ImageMaster® HR 2 is supported by the equally newly developed software MTF Studio.

Image

For medium and larger lenses, e.g. in camera lens manufacturing and the development of aerial lenses or lenses for space exploration, the horizontally mounted ImageMaster® Universal offers the highest accuracy and maximum stability.

Several useful functions are integrated which help the user to scan and perceive the correct image position of the sample under test. Changing the measurement mode is easy and time-saving. All important measurements for the imaging properties are quickly accessible.

Innovative design, high quality and long-life components are combined in the ImageMaster® Universal with user-friendly software. Its horizontal construction facilitates testing of large lenses.

The Effective Focal Length (EFL) or equivalent focal length is the distance from the focal points of the lens to the respective principal planes. The EFL determines the magnification of a lens and hence the image size. Because the principal planes are usually inside the lens at unknown locations, the direct measurement of the EFL is difficult.

Apr 1, 2020 — Answer:1.Mirror:- A Mirror is an objects that reflect lights in such way that for,incident light in some range of wavelengths ...

However, the EFL can be measured quickly and with sufficient accuracy using the method of measuring the magnification of a double bar target. Certified master lenses from PTB (National German Standard Institute) are available at TRIOPTICS and are used for the calibration of the measurement setup. The measurement data are thus directly traceable to international standards.

The MTF measurement is an important tool for the objective assessment of the imaging performance of optical systems. Moreover, the MTF can be calculated from the lens design data giving designers of optical systems the ability to predict system performance reliably. The manufacturer can then compare the image quality of real lenses with the expectations from the design phase.

Our customers in R&D benefit from highly precise and repeatable measurement results. The wide range of measurement parameters leads to high efficiency in research and development as well as in prototype testing and production.

Due to the easy system conversion from VIS to NIR, the specific requirements from various areas, including the automotive industry, development of mobile phone lenses, and the military and aerospace sectors are covered.

Aug 28, 2017 — The eyepieces are the optical lenses where we see the final images of specimens (see Figure 1). · The final image of a microscope can be watched ...

A chief ray is the ray from an off-axis object point which passes through the center of the aperture stop of an optical system. The chief ray enters the optical system along a line directed towards the midpoint of the entrance pupil, and leaves the system along a line passing through the center of the exit pupil. To measure the angle between the optical axis and the chief ray on the image side the following method is used: The lens under test is illuminated by the collimator at different angles corresponding to the object sided chief ray angles. The detector head is moved to the image field position at which the lens focuses the image. Now the detector head is moved towards the lens in small steps while the software registers the lateral movement of the focused spot. From these lateral movements the CRA is calculated.

The ImageMaster® HR 2 offers versatile functionality for testing the image quality of small and medium-sized lenses, e.g. for smartphone, photo and film cameras. With the ImageMaster® HR TempControl test samples, which have to provide their optical functionality and performance at extreme temperatures, can be measured in a wide temperature range.

The ImageMaster® HR has been the MTF test station preferred by R&D laboratories worldwide and has always offered highest accuracy and repeatability. As the successor to the worldwide standard for image quality testing of lenses, the newly developed, ImageMaster® HR 2 is available, e.g. for smartphones, surveillance cameras and camera modules for the automotive industry.

The Modulation Transfer Function (MTF) is an important aid to objective evaluation of the image-forming capability of optical systems. Not only that the MTF provides a means of expressing the imaging quality of optical systems objectively and quantitatively, but it can be calculated from the lens design data. In this way it allows optical and systems designers to predict reliably the performance of the optical systems. The manufacturers can compare the image quality of the manufactured lenses with the design expectations.

The ImageMaster®-Software measures continuously the light intensity of the test pattern in order to avoid saturation. In this way the necessary data is available for determining the relative illumination following ISO 13653:1996.

Shop in our free App today. Open .us · Sign in › · your ... Edmund Scientific Catalog 762 Astronomy Science Optics Metric Alternative Energy Psychology Hobbies.

Modulation transfer function

Image

The products ImageMaster® HR 2 and Universal fulfill highest customer requirements for image quality testing. ImageMaster® HR 2 is the preferred MTF test station for R&D labs worldwide. Measurements with increased accuracy and flexibility are the main focus.

One main feature key feature when using the software with the ImageMaster® Universal is the support of UV or IR detectors employing the scanning aperture method.

The depth of focus can be determined using a “through focus scan” of the MTF and setting appropriate tolerances for the drop in MTF. The depth of focus between the set tolerances will be measured and displayed.

In this so-called finite-finite imaging condition the illuminated slit or crosshair target is directly moved in the object plane of the sample. In the more common infinite-finite imaging condition, the illuminated slit or crosshair is part of a collimator projecting the target to infinity. The collimator is then oriented at different off axis angles for characterizing the MTF at the corresponding image fields. Figure 4 shows the typical setup for this imaging condition.

The wide model range of ImageMaster® HR 2 and Universal allows measurement of a large number of optical parameters over a wide spectral range. The ImageMaster® HR can be used to measure lenses in the spectral range NUV-VIS-NIR-SWIR-MWIR-LWIR. The ImageMaster® Universal is flexibly suitable for MTF Testing in the entire spectral range UV-VIS-NIR-SWIR-MWIR-LWIR from 200 to 13,000nm.

The MTF measurement can be accomplished at a single wavelength or in a spectral range covering a finite band of wavelengths. The resulting measurement data are known as monochromatic or polychromatic MTF values, respectively.

A more complex measurement can be done simulating the range of object distances covered by the lens and measuring the MTF at the corresponding image distances.

MTFtesting Mastercard

By convention, the modulation transfer function is normalized to unity at zero spatial frequency. For low spatial frequencies, the modulation transfer function is close to 1 (or 100%) and generally falls as the spatial frequency increases until it reaches zero. The contrast values are lower for higher spatial frequencies as shown above. As spatial frequency increases, the MTF curve falls until it reaches zero. This is limit of resolution for a given optical system or the so called cut off frequency (see figure below). When the contrast value reaches zero, the image becomes a uniform shade of grey.

The ImageMaster® HR 2 and Universal are available in numerous variants and also enable with different collimator options, e.g. mirror collimators, precise measurement of samples with large focal length ranges. For optical systems that are used under different temperature and weather conditions, measurements in a wide temperature range are possible with the ImageMaster® HR TempControl.

For finite conjugate measurements a finite stage is available as upgrade in two different stage lengths for all wavelength ranges:

FOV and focal length

Image

To determine the field curvature a set of through focus measurements at different positions in the field are taken. The MTF maxima and the corresponding positions in field are determined. The values are collected by a software routine and displayed in graphical and tabular form.

Relative illumination in an optical system is the gradual reduction of the image brightness with increased off-axis angle. This phenomenon results from the fall of, which is approximated by the cos4 or “cosine four law of the illumination falloff. Additionally there is the effect of the apparent limitation of the clear aperture depending on the field angle. Relative illumination is defined as the ratio of the central transmission and the transmission at the edge of the field of view.

Contrast vs spatial frequency. This figure shows the MTF of the diffraction limited optics and a measured MTF referring to Fig. 1

This article inspired you? Are you looking for further knowledge transfer? Then you might also be interested in the following topics…

Raise the body tube by turning the coarse adjustment knob until the objective lens is about 2 cm above the opening of the stage. Rotate the nosepiece so that ...

Powerful functions assist the user in performing the necessary measurement processes to determine a variety of parameters to determine the optical performance in the extended temperature range.

All MTF measurements can be performed with the ImageMaster® Universal in finite, infinite and afocal measurement position.

The Modulation Transfer Function (MTF), describing the resolution and performance of an optical system, is the ratio of relative image contrast divided by relative object contrast MTF = Relative Image Contrast/Relative Object Contrast. When an object (illuminated target or reticle) is observed with an optical system, the resulting image will be somewhat degraded due to inevitable aberrations and diffraction phenomena. In addition, a real lens will not fully conform to the design data.

TRIOPTICS provides customers maximum versatility offering a combined test system. The three exchangeable measurement heads offer the following possibilities:

The versatile functionality and high performance make the user-friendly ImageMaster® MTF Studio software package the preferred choice for R&D and laboratory work. High-performance functions help the user to optimize the measurement processes.

The ImageMaster® HR 2 is our completely redesigned new version of the long-time successful ImageMaster® HR – the worldwide standard for image quality testing of small and medium-sized lenses e. g. for smartphone-, photo- and film cameras.

Field curvature is an optical aberration in which the focus position changes from the center to the edge of the field of view. The curvature of the image field is a lens aberration that causes a flat object surface to be imaged onto a curved surface rather than a plane.

The software offers high flexibility for measurements in the NUV-, VIS- and NIR spectrum. Automatic measurement sequences ensure easy operation and the data can be output in CSV/MHT.

Usually the MTF is used in its one-dimensional form, calculated for one azimuthal section through the image plane. The azimuth (section plane) of the object pattern is called sagittal azimuth when the prolongation of the slit or object passes through the reference axis. When the prolongation of the slit pattern is perpendicular to the reference axis, the azimuth is called tangential azimuth.

Due to the dispersion of refractive optical systems the image position and also magnification of an optical system depends on the wavelength of the light. The dependence of the axial image position on the wavelength is called Chromatic Focal Shift. The dependence of the magnification on the wavelength is called Lateral Chromatic Aberration. Both aberrations can be measured with the ImageMaster®. The collimator of the ImageMaster® is equipped with different narrow bandwidth color filters. Together with the highly corrected relay optics this enables the system to focus in axial direction to the different image positions for different colors. The image position measurement can be done with submicron accuracy. Measuring the lateral image position for different object angles enables the system to measure the lateral chromatic aberration.

Sample Holders for various diameters and a lifting table for large samples are available for the Image Master® Universal.

LensMTF

Country*AfghanistanAlbaniaAlgeriaAmerican SamoaAndorraAngolaAnguillaAntigua and BarbudaArgentinaArmeniaArubaAustraliaAustriaAzerbaijanBahamasBahrainBangladeshBarbadosBelarusBelgiumBelizeBeninBermudaBhutanBoliviaBonaireBosnia and HerzegovinaBotswanaBouvet Island (Bouvetoya)BrazilBritish Indian Ocean TerritoryBritish Virgin IslandsBrunei DarussalamBulgariaBurkina FasoBurundiCambodiaCameroonCanadaCape VerdeCayman IslandsCentral African RepublicChadChileChinaChristmas IslandCocos IslandsColombiaComorosCongoCook IslandsCosta RicaCote d'IvoireCroatiaCubaCuraçaoCyprusCzech RepublicDenmarkDjiboutiDominican RepublicEcuadorEgyptEl SalvadorEquatorial GuineaEritreaEstoniaEthiopiaFalkland IslandsFaroe IslandsFijiFinlandFranceFrench GuianaFrench PolynesiaFrench Southern TerritoriesGabonGambiaGeorgiaGermanyGhanaGibraltarGreeceGreenlandGrenadaGuadeloupeGuamGuatemalaGuernseyGuineaGuinea-BissauGuyanaHaitiHeard Island and McDonald IslandsHoly See (Vatican City State)HondurasHong KongHungaryIcelandIndiaIndonesiaIranIraqIrelandIsle of ManIsraelItalyJamaicaJapanJerseyJordanKazakhstanKenyaKiribatiKoreaKuwaitKyrgyz RepublicLao People's Democratic RepublicLatviaLebanonLesothoLiberiaLibyan Arab JamahiriyaLiechtensteinLithuaniaLuxembourgMacaoMacedoniaMadagascarMalawiMalaysiaMaldivesMaliMaltaMarshall IslandsMartiniqueMauritaniaMauritiusMayotteMexicoMicronesiaMoldovaMonacoMongoliaMontenegroMontserratMoroccoMozambiqueMyanmarNamibiaNauruNepalNetherlandsNetherlands AntillesNew CaledoniaNew ZealandNicaraguaNigerNigeriaNiueNorfolk IslandNorthern Mariana IslandsNorwayOmanPakistanPalauPalestinian TerritoryPanamaPapua New GuineaParaguayPeruPhilippinesPitcairn IslandsPolandPortugalPuerto RicoQatarReunionRomaniaRussian FederationRwandaSaint BarthelemySaint HelenaSaint Kitts and NevisSaint LuciaSaint MartinSaint Pierre and MiquelonSaint Vincent and the GrenadinesSamoaSan MarinoSao Tome and PrincipeSaudi ArabiaSenegalSerbiaSeychellesSierra LeoneSingaporeSint Maarten (Netherlands)Slovakia (Slovak Republic)SloveniaSolomon IslandsSomaliaSouth AfricaSouth Georgia & S. Sandwich IslandsSpainSri LankaSudanSurinameSvalbard & Jan Mayen IslandsSwazilandSwedenSwitzerlandSyrian Arab RepublicTaiwanTajikistanTanzaniaThailandTimor-LesteTogoTokelauTongaTrinidad and TobagoTunisiaTurkeyTurkmenistanTurks and Caicos IslandsTuvaluU.S. Virgin IslandsU.S. Minor Outlying IslandsUgandaUkraineUnited Arab EmiratesUnited KingdomUnited States of AmericaUruguayUzbekistanVanuatuVenezuelaVietnamWallis and FutunaWestern SaharaYemenZambiaZimbabwe

Manufacturing errors, assembly and alignment errors in the optics will deteriorate the overall imaging performance of the system. As a result, in the image, bright highlights will not appear as bright as they do in the object, and dark or shadowed areas will not be as black as those observed in the original patterns. In general an illuminated target can be defined by its spatial frequency (number of bright and dark areas per millimeter) and the contrast (the apparent difference in brightness between bright and dark areas of the image).

Polarization refers to the direction of travel of ... For example, linearly oriented structures such as ... Wave Polarisation. Animation showing four ...

Distortion is the percentage of change in magnification between the center of the field of view and off-axis positions in the field of view. In order to determine the distortion a different method of measuring the EFL is used:

MTF

The measurement accuracy is traceable to international standards. The correlation to production testers and other devices enables worldwide consistent measurements independent of location as well as consistent measurement results in the product lifecycle from R&D to production.

• Motorized finite conjugate stage with manual or motorized object generator. The motorized object generator illuminates the reticle in the direction of the sample for off-axis measurements. This is needed for small samples or low light conditions • Various collimators with focal length and clear aperture for high flexibility • Motorized reticle and filter changer for infinite conjugate to measure with least interaction of an operator. The lateral chromatic aberration can be measured more accurately as the filter will be changed automatically with no vibration of a manual change • With the veiling glare upgrade for ImageMaster® HR it is possible to measure the Glare Spread Function (GSF). By off-axis measurements and rotation of the specimen around its center, the GSF can be measured over the entire field of view of the sample.

The depth of focus is the extent of the region in front of and behind the image plane in which the image will appear to be sharp.

The F-Number of a lens is defined by the ratio between the EFL and the diameter of the entrance pupil. The ImageMaster® series instruments use the ISO-517 method to accomplish the measurement: First the EFL is measured according to the procedure described before. Then the sample is turned around with the entrance pupil facing towards the detector head. The diameter of the entrance pupil is measured by first focusing on the left, then on the right edge of the pupil. The travelling distance of the image field stage represents the diameter of the entrance pupil. By choosing the proper head lens of the detector head even pupils positioned far inside of the system under test can be measured.

The prism is usually fitted on one side of the glasses, in front of the eye with the weakest vision. Occasionally a prism may need to be fitted to both lenses ...