Camera ccd sizein inches

Resolution: 2048 × 2048 Pixel size: 15 µm Well suited to the most demanding applications, such as astronomy

Resolution: 2208 × 320 Pixel size: 30 µm Split frame transfer backside thinned area array CCD image sensor with 30 μm x 30 μm pixels, selectable outputs and exposure control

Resolution: 6144 × 6160 Pixel size: 10 µm Back-illuminated spectral response and very low read-out noise give exceptional sensitivity.

Resolution: 12288 × 64 Pixel size: 7 µm dual zone, unidirectional TDI CCD with continuous vertical clocking and 16 or 8 selectable outputs per zone

Resolution: 512 × 580 Pixel size: 16 µm Back illuminated CCD which maximizes the quantum efficiency in the low energy X-ray region.

Camera ccd sizenikon

All Teledyne Imaging devices can be supplied partially or fully customized to fit the application and achieve the best possible system performance. Sensor design, manufacture, assembly and test are carried out in-house. Sensors can be back-illuminated for highest sensitivity, designed with very low noise, and available in multiple formats and package types. Teledyne Imaging has capabilities and vast experience in designing and delivering not only CCDs but integrated camera systems, mosaics, and focal planes.

Resolution: 8192 × 80 Pixel size: 7 µm TDI CCD image sensor with 7 μm x 7 μm pixels, selectable outputs and 100x antiblooming.

Camerasensorsizechart

For additional insights into photonics topics like this, download our free MKS Instruments Handbook: Principles & Applications in Photonics Technologies

Resolution: 512 × 512 Pixel size: 16 µm Well suited for scientific imaging where the illumination is limited.

Resolution: 128 × 128 Pixel size: 24 µm Low noise output amplifier circuit

Resolution: 2048 × 2048 Pixel size: 13.5 µm Well suited to the most demanding applications requiring a high dynamic range.

Resolution: 4096 × 96 Pixel size: 7 µm Backside illuminated five bands TDI CCD image sensor

Resolution: 1056 × 1027 Pixel size: 13 µm Full-frame architecture well suited to the most demanding scientific applications.

Resolution: 1252 × 1152 Pixel size: 22.5 µm Full-frame imaging device with two image area sections that can be clocked separately

Resolution: 720 × 1152 Pixel size: 22.5 µm Full-frame imaging device with two image area sections that can be clocked separately

Resolution: 4096 × 4112 Pixel size: 15 µm Exceptional sensitivity with minimum readout times

Resolution: 24100 × 128 Pixel size: 7 µm Multispectral, multi-die TDI image sensor array

Resolution: 0 × 0 Pixel size: 50 µm Back illuminated, deep depleted, low noise CCD image sensors for use in X-ray detection

Camera ccd sizecomparison

Resolution: 240 × 240 Pixel size: 24 µm Designed for very high frame rate and low signal applications

Image

Resolution: 2048 × 2064 Pixel size: 15 µm Large image area for demanding scientific imaging applications

Resolution: 2051 × 4096 Pixel size: 15 µm Full frame imaging CCD designed to operate in Inverted Mode for low dark signal.

Resolution: 2048 × 515 Pixel size: 13.5 µm Well suited to the most demanding applications, such as spectroscopy.

Visible and infrared image sensors that set the standard for the world's leading ground-based astronomy applications and observatories

Resolution: 4096 × 4096 Pixel size: 12 µm Large image area with back-illuminated spectral response and very low read-out noise. Designed for demanding astronomical applications.

Resolution: 80 × 80 Pixel size: 24 µm Optimised for use at high frame rates

This catalogue presents Teledyne Imaging’s detectors with a high space technology readiness level (TRL) that are available for consideration in instrument designs for future space missions. An overview of each detector is given, along with key parameters and a description of the relevant space heritage.

Phonecamerasensorsize

Resolution: 264 × 2048 Pixel size: 15 µm Full frame spectroscopic format sensor

Resolution: 1024 × 1024 Pixel size: 10 µm Extreme performance in high frame rate ultra-low light applications

Resolution: 9216 × 9232 Pixel size: 10 µm Large image area for demanding astronomical and scientific imaging applications

Resolution: 1024 × 512 Pixel size: 50 µm Back illuminated, deep depleted, low noise CCD image sensors for use in X-ray detection

The distribution of the power and energy density in the beam is considered a key parameter in most laser applications; it determines the effectiveness of laser processing in the material. This parameter is calculated by dividing the emitted power or energy by the cross-sectional area of the focused beam (details regarding such laser parameters are given in Radiometric Measurement). The higher the power or energy density in the focus, the more efficiently the laser processing operation performs. An unexpected increase in focal spot size can severely impact the beam's power density leading to deleterious effects such as:

Resolution: 2048 × 2064 Pixel size: 15 µm Back Illuminated Scientific CCD Sensor

Resolution: 4096 × 3112 Pixel size: 12 µm Designed for the World Space Observatory Ultraviolet Spectrographs (WUVS) instrument, Teledyne e2v is supplying the CCD and the assembled cryo-cooled UV detector subsystems.

Camera ccd sizein mm

Choose products to compare anywhere you see 'Add to Compare' or 'Compare' options displayed. Compare All Close

Furthermore, one should not underrate the economic environmental impacts of consuming more processing gases. Significant energy is expended in the production of gases such as argon, which negatively affects the overall sustainability and end price of the manufactured product. At the same time, as more processing gases are consumed, more processing by-products - both gaseous and particulate - are emitted. Such emissions can reduce the quality of the optics, resulting in further reduction in beam quality. Figure 1 depicts the impact of low beam quality on costs per part.

Resolution: 2048 × 1024 Pixel size: 13.5 µm CCD Sensor with full frame architecture, back illumination technology, and an extremely low noise amplifier. Well suited to the most demanding applications such as astronomy.

Teledyne Imaging's Charge Coupled Detectors (CCDs) have extensive heritage and a wide variety of formats and customized features, making Teledyne Imaging  the leading supplier of sensors for Space Science, Ground-based Astronomy, and Earth Observation applications over 40 years with an impressive record of successful deliveries to a wide range of customers.

Camera ccd sizein cm

Resolution: 12288 × 128 Pixel size: 7 µm Five band multispectral TDI CCD image sensor with selectable stages.

Resolution: 384 × 288 Pixel size: 22 µm Inverted mode X-Ray to NIR sensor primarily intended to suit the requirements of astronomy and scientific measuring instruments.

Resolution: 600 × 600 Pixel size: 40 µm Close butted back-illuminated CCD

Resolution: 4096 × 4004 Pixel size: 10 µm Back illumination and an extremely low noise amplifier

Resolution: 384 × 1024 Pixel size: 27 µm Close butted CCD, with a dead region of less than 300 microns wide on three sides

Resolution: 36200 × 128 Pixel size: 7 µm Backside thinned, multispectral, multi-die TDI image sensor array

Yes, opt-in.  By checking this box, you agree to receive our newsletters, announcements, surveys and marketing offers in accordance with our privacy policy

Resolution: 1024 × 1024 Pixel size: 13 µm Back illumination technology and extremely low noise amplifiers

Resolution: 1022 × 2050 Pixel size: 26 µm High readout rates and high signal capacity

Resolution: 1024 × 255 Pixel size: 26 µm Designed for use in the scientific spectroscopy instrument market

Resolution: 2048 × 4612 Pixel size: 13.5 µm Well suited to the most demanding astronomical and scientific imaging applications.

Resolution: 1404 × 1350 Pixel size: 20 × 30 µm CCD sensor with a graded anti-reflective coating unique to Teledyne e2v

Camera ccd sizechart

Resolution: 12288 × 128 Pixel size: 7 µm 12k pixel backside illuminated, bidirectional, multispectral TDI CCD

Resolution: 1024 × 1024 Pixel size: 13 µm Extreme performance in high frame rate ultra-low light applications

Resolution: 1024 × 1024 Pixel size: 8.5 µm Frame transfer CCD array image sensor with 8.5 μm pixel, MPP mode and 100x antiblooming

Resolution: 6144 × 6160 Pixel size: 15 µm Four separately connected image area sections to allow full-frame, frame transfer, split full-frame or split frame-transfer modes

Resolution: 1404 × 1350 Pixel size: 20 × 30 µm CCD image senor optimized for ultraviolet and visible wavelengths

Resolution: 2048 × 4104 Pixel size: 15 µm Back Illuminated, Non Inverted Mode Operation, High-Rho Enhanced Red Sensitivity