At this point we will try to achieve two objectives: reducing spherical aberrations and keeping the focal point as close to 50 mm as possible.

There are also different configurations of achromatic doublets you may want to consider, for example: Littrow, .Fraunhofer and Clark doublets.

Apochromaticaberration

Covering the spectrum in even (Flight 1) and odd (Flight 2) 20 nm FWHM steps for essential filter performance at a contained cost.

Explore our extensive line of HPLC and UHPLC column hardware optimized to enable selectivity, efficiency, and high-quality separation performance in your flow paths.

We still see significant coma and spherical aberration at this point: the chromatic focus shift however has decreased from 1.5 mm to less than 0.1 mm. There are no significant changes on spherical or coma at this point. So we will try to correct for coma next.

Apochromatic vsachromatic

Explore manual valves for lower frequency use, rotary shear valves that meet the high duty cycle requirements of UHPLC, and more

Enhancing reliability, preventing leakage, minimizing carryover, and enhancing usability. These are a few of the many advantages in partnering with us for custom fluidic solutions.

Select the elements of your fluorescence system and quickly calculate a relative signal brightness, autofluorescence level, and signal to noise ratio.

Our IDEX Health & Science Center of Excellence in Rochester, New York is the home to our Life Science Optics division. Take a tour of our world class optical coating facility, with scaled-up sub-system manufacturing and expanded optical sub-system design capabilities.

Explore a wide range of laser and LED illumination light engines to meet your application needs from Next Generation Sequencing, Cytometry, Fluorescence Microscopy, and Spectroscopy in clinical and research environments.

where V1 and V2 are the Abbe numbers for the first and second elements, respectively. Solving for f1, and f2 from Eq. 1 and Eq. 2, we get:

We first need to be familiar with the concept of the Abbe Number (or V-number), a measure of the dispersion of glass; the higher the Abbe number, the lower the dispersion. Figure 1 shown the Abbe diagram where we can plot the V-number versus the refractive index for several types of glass.

We calculate some of the Seidel aberrations and look at the Ray Analysis graphs (we should talk about them at another time). We calculate a chromatic focal shift of 1.5 mm along the axis, a maximum spherical aberration of 4mm at 20-degrees, and a Seidel coefficient for coma (third-degree) of 0.157.

Monochromaticaberration

Download our new Semrock Raman Optical Filter Catalog for the latest Raman updates, technical notes, and optical filter product information.

With over 20 years of experience and 800+ unique optical systems designed, Optics for Hire specializes in advanced optical engineering. If it uses light, we've worked on it.

Figure 3 shows the changes on the first and fourth surfaces. We changed the first surface from 24.77mm to 23.8mm and the fourth surface from 59.33mm to 60.2mm. After these changes, the chromatic aberration is still under 0.1mm as before, but the Siedel Coma coefficient has been reduced to 0.0305 (from our original 0.157). Also the spherical aberration has been reduced to almost 2mm at 20-degrees, so we will try to improve it next.

In the previous step, we calculated the focal length of each lens, but we still need to define the radii of curvature. So let’s define those before attacking coma. To simplify (and reduce the length of this article), we will assume symmetric lenses with equal radii of curvature in the front and back surfaces of each lens. A first approximation for our lenses can be found using the following equations:

Let’s change the spacing between the first and second lens, and also the radius or curvature of the first surface of the second lens. We keep this iteration going until we reach the following lens combination.

3. The negative lens (flint glass) should preferably have a higher refractive index than the positive lens (crown glass)

Crown glass on the other hand is used to fabricate the positive component. Crown glass has a low dispersion (with an Abbe number above 50) and low refractive index (usually below 1.5), although some glass like BK7 has a refractive index that overlaps with some flint glass. Crown glass names usually include a “K” at the end (form the german “kron”, crown). Some types of crown glass are: K, SK, BK, LaK, LaSK and many others.

2. A large difference in Abbe number will help us to have lower curved surfaces and will help in optimizing coma and spherical aberrations

Looking to replace your CCD camera and achieve similar performance? Consider an IDEX Health & Science CMOS camera with higher resolution and throughput.

IDEX Health & Science, LLC is the global leader in life science fluidics, microfluidics, and optics, offering a three-fold advantage to customers by bringing optofluidic paths to life with strategic partnerships, breakthrough solutions, and proven expertise. As one of the few companies in the world with component, sub-system, and application-level experts, IDEX Health & Science helps instrument developers solve the most demanding fluidic and optical challenges in a wide array of applications.

Achromaticlens

Accurately monitor and control your pressure to achieve accurate instrument output and maximized system capabilities with our sensors.

Here we will show the process of achromatic doublet optimization. We’ll start with our requirements. We’re looking for a 50mm focal lens with a 20-degree FOV and 30 mm diameter.

We will be using an achromatic doublet without referring to any specific application for this example. So we will be working with two common glasses: BK7 (abbe-number = 64.166 and n_green = 1.52237) and SF2 (Abbe-number = 33.819 and n_green = 1.6612). To calculate the radius of curvature for our lenses , we will be using equations 3 and 4.

where f1, and f2 are the focal length of the first, and second element, respectively, and feq is the equivalent focal length of the system. The second equation we need is:

One of the most common optical structures is the achromatic doublet. It is used to reduce chromatic aberrations. At its most basic, it is a two lens system configuration where one lens is a concave lens, usually made of a flint glass, and the other is a convex element, usually made with crown glass.

Before we start, we need to mention that there are different ways to optimize any design; there is no “formula” that an engineer can apply to yield the best results. It is a process that requires revisions and feedback. It is, in a sense, an art that benefits from the optical engineer’s technical knowledge. What is presented here is just a method we have used in the past with acceptable results.

The last aberration that we will correct for is spherical aberration. Once the first two aberrations are solved for, spherical aberration can be relatively simple to tackle. We may say that we have two tuning variables that we can modify to produce either a coarse or fine tuning. If we have a significant amount of spherical aberration, we can modify one of the internal radii of curvature of our lenses (i.e. surface two and three). If we have a small amount of spherical aberrations, we can modify the spacing between lenses.

The presented method is just one that may help you to do a simple optimization. More complicated methods involve reducing chromatic aberration for a specific line and calculating coma coefficients for each optical element, and minimizing their combined effect. This method gives a better starting point to reduce aberrations.

The combination of unique materials (flint glass and crown glass) and the lens shapes of the doublet, an optical engineer can use the science of light to deliver lens solutions without chromatic aberrations.

Below you will find educational webinars about choosing the best optical filter for your application, as well as, tutorials on how to you SearchLight, how to clean optical filters, and more.

We can see that our focal length is closer to our required 50 mm. We also still have our coma coefficient around 0.02 (just a little bit lower than before) and the spherical aberration less than 3 mm at 20-degrees.

In order to reduce chromatic aberration, we need to find a way to match the lens focal length regardless of the wavelengths we are using. A way to do this is by using an achromatic doublet. As mentioned before, the achromatic doublet has two lenses: a negative lens (concave) and a positive one (convex). The basic idea is that both lenses will compensate their respective dispersions and cancel each other.

Our engineers and product management teams have collaborated to provide you with the Semrock Master Catalog from IDEX Health & Science. With proven results, we give you access to high-level engineering that will help make every photon count in your system.

From the spot diagram, we can see that there is significant coma (specially at full field) and some spherical aberration. Look at this entry to learn more about spot diagrams.

Once the glass types have been chosen, we can calculate the focal length of each optical element in our doublet with the following equations

Partner with our optical design and engineering experts to build a custom objective solution optimized for high-NA, wide field of view, and diffraction-limited resolution performance.

We will stop our discussion about optimization here.  As mentioned before, there are different ways to attack this problem, and there are more tools that we can use to analyze an optical system.  In future blogs, we will talk about ray intercept graphs and we can return to another example of optimization or simple analysis.

How do you manage the spectral complexities needed for spatial biology analysis? Steep edges and deep blocking are your solution.

Achromaticdoublet meaning

When correcting for one aberration, we need to keep monitoring the whole system: more often than not, lens optimization is a matter of compromising. Sometimes it is not possible to completely reduce all aberrations simultaneously.

We start by assuming that we have the goals of our designs, that is, we have the focal length, wavelength range, aperture diameter, FOV already defined. Based on this information, we have several variables that we can manipulate, those are:

With over 15 years of experience and 500+ unique optical systems designed, Optics for Hire specializes in advanced optical engineering. If it uses light, we've worked on it.

At this point, we will be changing the radius of curvature of the first and fourth surfaces. We’ll try to keep the focal length as close as possible to 50mm. There are different ways you can try to do this optimization. OSLO and Zemax have different algorithms that can be used for different kinds of optimizations. For this example, however, we will just change the values in small amounts.

Now, to correct for coma, we will adjust the radii of curvature of the first and fourth surface, (i.e. the first surface of the first lens and the second surface of the second lens). In order to keep the optical power unchanged, we would like to have (1/R1)+(1/R4)=const. So, increasing one radius will decrease the other one. We will repeat this process until an acceptable coma reduction is achieved.

The negative component is usually made of what is called “Flint glass”. Flint glass has some lead and a particular high chromatic aberration (described by an Abbe number below 50), and high refractive index (usually above 1.55). Some types of flint glass are: F, LF, SF, KF, BaF, BaLF. Lead-free flint glass usually has a “N” before their name. For example N-SF8.

Achromaticdoublet formula

Sphericalaberration

If you are a North American laboratory, university, or government agency, please consider placing your order directly with our distribution partner, AVR Optics. Visit AVR Optics

Achromaticcolor

Challenged with minimizing expensive reagent volumes while maintaining a cost effective, reliable platform? Partner with our fluidic design and engineering experts to manufacture subsystem solutions to mitigate risk to performance and minimize cost.

Explore our comprehensive line of tubing, connectors, fittings, and flow control devices that meet the increasingly demanding requirements of today’s high performance analytical fluidic systems.

From those equations we get an R_1 = 24.77 mm and R_2 = -59.33. At this point, we will have the same radii of curvature for the front and back surfaces, so we will have a biconvex and a biconcave lens, as shown in Fig 3

Looking for a filter set to go with your fluorophore? Use the chart on this page to find which Semrock optical filter sets are compatible with popular fluorophores.

First, we need to understand what is chromatic aberration and why it occurs. Chromatic aberration is the effect caused by the change in refractive index for a given material at different wavelengths. For example, BK7 has a refractive index of 1.5228 at 480 nm (blue) and of 1.5131 at 700 nm (red). That basically means that if we have a biconvex lens made with BK7, it will focus red and blue light at different points, resulting in chromatic aberration. This is shown in Figure 1.

Optical filters can be searched by individual filters and by set. You will also still have access to the e-store left navigation filtering that you are used to from the historic semrock.com to search by wavelength, filter families, fluorophore, filter type, light source, laser wavelength, edge steepness, flatness, application, and more.

The first aberration that we will try to correct for is chromatic aberration. This is, after all, one of the main reasons we will be using an achromatic doublet. As mentioned in the early article, an achromat is formed by using a flint glass and a crown glass. Using the right combination of glasses will reduce chromatic aberration but the choice of glass can be daunting. How do we know what type of glass to use?

Explore our broad portfolio of vacuum degassing assemblies to control bubbles in a wide range of system-fluids and flow-rates.

If we can correct the lens shown in Fig. 1 with an equivalent achromatic doublet, we will set feq to 50 mm and choose two materials for our lenses. For the flint glass, we choose N-SF8 with an Abbe number of 31.31 and for crown glass, we choose N-BK7 with an Abbe number of 64.17. Substituting these values into Eq. 3 and Eq. 4, we obtain values of 25.61mm and -50.48 for f1 and f2, respectively. Figure 2, shows a chromatic aberration using these numbers (note: the lens is not optimized).