The resolution can be expressed in terms of the number of theoretical plates, separation factor, and retention factor, as shown in equation (4).

Micrometer stagechart

Customer is responsible for shipping charges when making returns and shipping/handling fees of original purchase is non-refundable.

Multidimensional chromatography uses a combination of several chromatography techniques, separation modes, and columns to separate multiple components. It achieves significantly higher separation than normal one-dimensional chromatography. Various separation modes and the corresponding mobile phases can be selected for HPLC, and the diverse permutations available suggest the possibility of achieving a degree of selectivity not possible using one-dimensional separation alone.

MicroscopeStage Micrometer

Items returned within 14 days of their original shipment date in same as new condition will be eligible for a full refund or store credit.

JavaScript seems to be disabled in your browser. For the best experience on our site, be sure to turn on Javascript in your browser.

Micrometer stagemeasurement

Equation (1) indicates that the resolution is the difference between peak retention times divided by the average peak width. In a peak with Gaussian distribution, the peak width is W = 4 σ (where σ is the standard deviation) and the peak FWHM is W0.5h = 2.354σ. Substituting these relationships into equation (1) gives results in equation (2).

The resolution is represented as a numeric value, such as 0.8, 1.0, or 3.0. But what is the relationship between the number representing the resolution and the actual peak separation? At a resolution of 1.0, if the two peaks are assumed to have a Gaussian distribution and have the same peak height and peak width, then the difference in retention time from equation (1) becomes 1.0W, or 1.0 × 4σ = 4 σ. In the case of a Gaussian distribution, 4 σ encompasses 95.4 %, such that the peaks overlap by 2.3 % ((100 % - 95.4 %)/2). This indicates that 2.3 % of the peak intrudes into the other peak from a perpendicular line drawn in the trough. Similarly, a resolution of 1.5 indicates a difference in retention time of 1.5× 4σ = 6σ, which corresponds to an overlap of 0.15 % ((100 % - 99.7 %)/2). See Fig. 2.

In addition to resolution, the separation factor (α) is also used as an indicator of the separation of two peaks. The separation factor is defined as the ratio of the retention factors (k), as shown in equation (3).