Collimated beammeaning

Reach for a rugged Fluke 61 IR Thermometer for jobs that require measuring temperature in hard-to-reach, hot, rotating, or dangerous situations. The Fluke 61 non-contact thermometer delivers accurate readings over a broad temperature range from -18 to 275°C (-0 to 525°F). Plus, the enhanced optics allow you to measure smaller objects further away.Monitor the status of electrical motors and electrical panels, research heating and ventilation problems and diagnose car malfunctions all with a comfortable, easy-to-use, handheld non-contact thermometer.

How to make acollimated beam

Quite frequently the most popular way to focus a laser diode beam is to use a two lens system where one lens collimates the highly divergent beam and the second lens focusses it. Alternatively, a single aspheric lens can be used to focus the beam for direct focusing, but in most cases, it causes severe aberrations, larger beam and lots of diffractions. By definition, beam quality implies a measure for how well a laser beam can be focused.

The most simple and popular way is to collimate a laser diode beam by using a single aspheric lens. (see Fig. 1). The larger is the focal length of this lens, the larger will the beam diameter be after collimation. Furthermore, if a certain beam adjustment has to be made, for example in order to expand the beam radius of a collimated beam, two lens system is often used - the so-called telescope. One lens with a negative focal length and the other with a positive one creates a setup to collimate and expand or shrink the beam.

Collimatedmeaning in Physics

Please share your ideas and questions with us, we will provide all possible best solutions! Come and contact us at sale@s-laser.com or +86-29-68590616!

Infrared thermometer for jobs requiring temperature measurement in hard-to-reach, hot, rotating, or dangerous situations

• Bright laser beam provides easy targeting • Display clearly supplies data at a glance • Shock-absorbing holster increases ruggedness • 0.2°C (0.5°F) resolution up to 275°C (525°F) • Backlight illuminates the screen in the dark • Automatic sleep mode after 7 s extends battery life • Alkaline batteries provide 4000 typical measurements

Collimated beamtesting

Collimated beamof light

The laser beam is focused through the focal lens. The focal lens acts like a magnifying glass and sunlight. For a 55mm lens, the laser beam passes through the lens and converges to the smallest point at about 55mm from the edge of the lens. The laser beam is concentrated to the smallest size at this "spot".

Image

Collimatedflashlight

Quite often CW lasers have a short cavity. The resonator of microchip DPSS lasers may vary from less than a millimeter to few millimeters. Cavities of single-mode laser diodes are in the range of hundreds of microns. Generally speaking, such short cavities produce highly divergent beams, which are not very usable in optical systems.

Reach for a rugged Fluke 61 IR Thermometer for jobs that require measuring temperature in hard-to-reach, hot, rotating, or dangerous situations. The Fluke 61 non-contact thermometer delivers accurate readings over a broad temperature range from -18 to 275°C (-0 to 525°F). Plus, the enhanced optics allow you to measure smaller objects further away.Monitor the status of electrical motors and electrical panels, research heating and ventilation problems and diagnose car malfunctions all with a comfortable, easy-to-use, handheld non-contact thermometer.

Image

Collimating lens

• Bright laser beam provides easy targeting • Display clearly supplies data at a glance • Shock-absorbing holster increases ruggedness • 0.2°C (0.5°F) resolution up to 275°C (525°F) • Backlight illuminates the screen in the dark • Automatic sleep mode after 7 s extends battery life • Alkaline batteries provide 4000 typical measurements

Alpha Controls & Instrumentation values all our customers who have placed their trust in us for over the past 40 years. LEARN MORE ABOUT US

If you want a smaller collimating laser beam, you must accept a larger divergence; On the contrary, if we want to keep the collimation of light over a long distance, it must get a larger beam size.

The divergence requirement in microscopy and spectroscopy is often less than 2 mrad (full angle) or even less than 1.5 mrad. In order to meet this requirement of modern analytical instruments, laser beams have to be collimated. This can be understood as putting a lens or a set of lenses in front of the laser cavity – does not matter be it a semiconductor laser cavity or a short DPSS resonator. However, for different types of lasers (diode and DPSS) the beam specifications are completely different.

A diode laser beam features low wavefront quality and high astigmatism - the divergence in the so-called fast axis is much higher than divergence in the slow axis. Various techniques are used for collimating such an astigmatic beam and in this consideration several objectives are important. The primary goal of collimation is to reduce divergence of a beam, the secondary goal is to eliminate astigmatism as much as possible, third – to improve wavefront quality, fourth – to make the beam less elliptical, fifth – to maintain good focusability.