Stereo microscopes are increasingly modular. This means that the same head can be used in conjunction with different focus blocks and stands. For example, Microscope.com offers a range of pole stands, track stands and boom stands.

Image

EdmundOpticsheadquarters

Do not adjust the focus with the focusing knob.  Adjust the focus for each eye separately using the eyepiece Dioptric adjustment rings.  Your microscope is now "parfocal". This means that as the microscope is zoomed from high to low magnification the image will stay in focus throughout the entire range. Each individual will have a different setting.

Adjust the microscope down to the lowest magnification using the Magnification adjustment knob. The image could be slightly out of focus.

Detectors are used to measure the illumination of a light source for a number of optical or spectrometry applications. Detectors consist of arrays of photodiodes or photodetectors that transmit electrical current when excited by collision from photons. Detectors enable the measurement of important light characteristics that are not conveniently acquired in other ways. A selection of photodiodes is also available with linked amplifier capabilities for easier, more precise measurement capacities.Detectors

Objective Lenses are the primary optical lenses on a microscope. In a low power microscope, they provide fixed magnification or zoom magnification. Zoom magnification is typically offered in a Greenough design or with a Common Main Objective.

JavaScript seems to be disabled in your browser. For the best experience on our site, be sure to turn on Javascript in your browser.

EdmundOpticslogo

EdmundOpticsaddress

Use the Magnification adjustment knob to set the highest magnification. Bring the image into focus with the focusing knob.  Center the image on some clear point of detail on the specimen.

Turn on The Transmitted/Oblique illuminator. Place a small solid specimen onto the stage such as a card, coin or any other flat, detailed object.

Diopter adjustment ring that allows for the possible inconsistencies of our eyesight in one or both eyes. Binocular microscopes also swivel (Interpupillary Adjustment) to allow for different distances between the eyes of different individuals.

As in a compound microscope, there are two optical systems in a compound microscope: Eyepiece Lenses and Objective Lenses.

EdmundOpticsCatalog

EdmundOpticscareers

A low power or stereo microscope typically employs objective lenses of 50x or less. It is used to view specimens that are visible to the naked eye such as insects, crystals, circuit boards and coins.

Adjust the eyepieces for the correct interpupillary distance to suit you. Do this by moving the eyepieces closer together or farther apart until a single field of view is observed (B). Now, set the Dioptric adjustment rings on both eyepieces to the zero position (A).

Light Meters are used to measure the light output of an illumination source for a number of optical applications. Light Meters are measurement devices that feature photodiodes to determine the level of light transmitted from a source. Light Meters possess simple, easy to read screens upon which measurements are displayed in one or more photometric units. Most Light Meters possess traceable NIST certification for proof of accuracy.

EdmundOpticswiki

EdmundOpticslocations

Working Stage is where the specimen to be viewed is placed. Pole and track stands have simple stages since lower magnification powers require less subtle movements than high power microscopes.

Spectrometers are used to measure the properties of light for a variety of applications including environmental or chemical analysis, fluorescence, or Raman. Spectrometers are optical instruments that can detect spectral lines and measure their wavelength or intensity. Spectrometers are ideal for determining compositional makeup for detecting weak light signals. Spectrometers can also be used to test the efficiency of an optical filter in order to determine whether a filter has properly blocked or transmitted specific wavelengths.

Edmund Optics has been a trusted source for quality optics, imaging and opto-mechanical components for more than 65 years.

Image

We use cookies to optimize site functionality and give you the best possible experience. To learn more including options for managing cookies, please check out our cookie policy.

Transmitted Illumination Since most specimens examined on a stereo microscope are opaque, a top light (Transmitted Illumination) is used to shed light on the specimen. Some stereo microscopes also include a bottom light (Incident Illumination).

Eyepieces or Oculars are what you look through at the top of the microscope. Typically, standard eyepieces have a magnifying power of 10x. Optional eyepieces of varying powers are available, typically from 5x-30x.