Kohärenz - Wörterbuch Deutsch-Englisch - koharenz
Focal pointof convexlens
Developments in sensor design and fabrication has enabled ever more smaller pixels to be packed into sensors. While more pixels can be better, there are trade-offs so the pixel size must be balanced to suit the needs of the application. There are three main aspects of how pixel size may impact imaging in addition to advances in other sensor technology enhancements such as back-illumination. These are summarized in table 1:
What is thefocallength of alensPhysics
Table 3: Simplified Signal to Noise comparison to illustrate the increase in the signal component provided by pixel size.
The focal length number tells us how much of the scene is captured in the picture. The lower the number the wider the view, and the more we can see. The higher the number, the narrower the view, and the less we can see. This is illustrated below – where the camera is stationary and the focal length (in white numerals) changes:
The architecture of CMOS however is different. Each row has to be read out sequentially on a row-by-row basis before binning - meaning that for the CMOS sensors in use today binning will not deliver the benefits to signal to noise (and speed) that it does for CCD. Digital binning for sCMOS still combines he values for 4 pixels in the case of 2x2 binning, but the read noise also increases 2-fold since the 2 pixel rows are read out.
Table 4: A comparison of the well depth of a selection of cameras. Note that maximum dynamic range may be restricted to certain modes available for each of the different camera models so is not presented here.
Andor’s iKon-L High Dynamic Range CCD camera offers outstanding resolution, field of view, sensitivity and dynamic range performance. It boast a proprietary large area 5-stage TE…
Focal pointin optics
A further benefit of wide dynamic range is from a practical sense – a sensor with a wide dynamic range is more often in range and avoids saturation requiring less adjustment of settings such as exposure.
Marana is Andor’s high performance sCMOS camera platform for Astronomy and Physical Sciences, featuring 95% Quantum Efficiency (QE) and market-leading vacuum…
There are some back-illuminated sCMOS cameras available with a pixel size of 11 µm pixel - which is a relatively large pixel when compared to typical CMOS cameras. These camera models, such as the Sona-11 sCMOS series, can take advantage of the light gathering power 3-fold higher than the 6.5 µm pixel size typically found in sCMOS cameras.
The final aspect of imaging performance that is linked to pixel size that can be beneficial is the well depth of the sensor and how this can be used to allow for high dynamic ranges. When implemented correctly, larger pixels often allow larger signal handing capacities than is possible using smaller pixels.
In the simplest comparison, camera 2 would look to provide a significantly higher signal to noise ratio since the signal component has increased for each pixel. To consider signal to noise for imaging cameras we need to use the following signal to noise equation to model the different signal and noise components involved:
For the smaller 4.6 µm pixels of the CMOS sensor 3x3 binning would be required to obtain the same photon collection area as a 13 µm pixel. 3x3 binning would thus increase read noise in this sensor type by a factor of 3.
A camera typically has focal length in a range of 10mm to 500mm. Different types of camera can have different ranges and speciality lenses can extend outside this range as well. A 10mm focal length would be a very wide lens (capturing a lot of the scene), and 500mm would be a very narrow lens (capturing only a small part of the scene – giving a large magnification like binoculars or a telescope).
The role of a pixel in a sensor is to collect photons within a subunit of the imaging area and subsequently convert these to an electrical signal. By digitizing these signals, an image can be recreated from the values received at each pixel. The more efficient at gathering light and converting this light to an electrical signal, the more sensitive the detector can be. This has been a key driver of CCD and CMOS sensor technologies with processes such as back-illumination and use of microlens being examples of ways to boost the efficiency of these devices. The latest sensors available have quantum efficiencies reaching up to 95% i.e. 95% of incoming photons are converted into electrons in the photosensitive region of the silicon compared to devices a little over 10 years ago being limited to around 60% peak QE.
While there is interest in imaging cameras with small pixels to preserve image detail at low magnifications there is still very much the need for cameras with larger pixel sizes for low light applications.
Figure 3: Cameras developed for sensitivity and highest possible signal to noise feature large pixel sizes. Illumination corrected for pixel size by normalizing per 13 µm area.
Focal pointof eye
There is some ability to calibrate a camera (which solves the principal distance) at one focus and execute your photogrammetric project at another focus. The actual discrepancy that is acceptable depends on your accuracy requirements and how much the focus changes. Generally a calibration done at 2m/6ft focus distance is acceptable for projects up to infinite focus (again depending on accuracy requirements), but may not be acceptable for a project where the focus distance was 50cm/20in.
Above we mention that focal length is related to focus distance. Focal length is the principal distance of a camera when it is focused at infinity. In photogrammetry we are interested in the camera’s internal geometry at the time photos were taken – so it is the principal distance that we want to know precisely in photogrammetry.
All lenses have a stated or specified focal length value (or range of values for a zoom lens). This printed number is actually its nominal length or the principal distance when the lens is focused at infinity. As you focus on objects that are closer to the camera, the principal distance changes. So for example, a 50mm lens focused on an object a few feet away might have a principal distance of 55mm lens at that time. The most extreme example of this is with a macro setting (a lens setting that allows you to focus on very close, very small objects, under 5″ in size for example). A lens that has a 50mm nominal focal length (so a 50mm principal distance when focused at infinity) might in fact have a 100mm principal distance when focused at a few inches! This is why it is good with photogrammetry (where precise geometry is needed) to calibrate a camera at the distance you will be working with.
When you buy a digital camera you will often see the specification “equivalent 35mm focal length”. What does this mean? Most digital cameras have imaging chips that cover much less area than a standard 35mm film frame. Since 35mm film cameras were the standard for so long in photography, much of the techniques and methods were developed around them. A 35mm film camera has a negative that is about 36mm wide by 24mm high (the “35” comes from the physical width of the film stock that is exactly 35mm wide). A ‘normal lens’ (has a field of view that appears ‘natural’ to humans) on a 35mm film camera has a focal length of 50mm.
In many cases though, the advantages of using focus (i.e. crisp targets and distinct features) with subtle effects on principal distance/focal length, outweigh the advantages of keeping focus and principal distance constant (i.e. potentially causing blur in some photos taken at a different distance).
Sona is Andor’s latest high performance sCMOS camera series, specifically for life science imaging applications. The new and enhanced Sona-6 Extreme is now more sensitive and faster!…
Andor’s NEW iKon-XL is a TE-cooled, very large area CCD camera platform, accommodating big field of view sensors that are ideally suited to long exposure astronomy applications.…
Focal point lensnikon
Cameras can have fixed lenses (sometimes called ‘prime’ lenses) which have just one focal length, or zoom lenses which allow the focal length to be varied (for example between 18mm-55mm, or 55mm-200mm). For high accuracy photogrammetric work in PhotoModeler, a fixed (or prime) wide lens (such as a 20mm lens on an APS-C frame camera) is recommended as the primary option, but different applications may require different focal lengths, and cameras with adjustable zoom lenses can still be used to achieve very good results with some extra procedural care over the focal length.
In the comparison illustrated in figure 3 we can see that the cameras with larger pixels provide the better signal to noise figures such as the iXon Ultra 888 and Sona-11 models which aligns with their intended applications, that prioritize sensitivity and detection, over spatial resolution at low light levels. The other CMOS models with smaller pixels do not provide as high signal to noise ratios even though they have low noise levels. They will provide improved spatial resolution.
Here we compare 2 cameras with all factors the same (QE, read noise, dark current) other than their pixel size and compare the effect of pixel size on relative the signal to noise performance as light of a given illumination falls on each sensor.
Camera manufacturers sometimes list these equivalents because some photographers are more familiar with 35mm cameras and they want to make it easier to understand. It also gives us a standard of reference for all the different format sizes. They may also list the multiplier factor. For example, the APS-C multiplier is around 1.6x. So a 32mm lens on an APS-C camera (like the Nikon D3200) would act like a 50mm lens on a 35mm film camera. Does focusing affect the focal length?
Learn how to use PhotoModeler with your camera to create detailed digital models: www.photomodeler.com/products/why.html
Andor’s iKon-M 934 low noise CCD camera series are designed to offer the ultimate in high-sensitivity, low noise performance, ideal for demanding imaging applications. These high…
A minuslenshas what type offocal point
A strict technical definition of focal length is difficult without providing a lot of background in lens theory, so we will use a simplification. You can think of focal length as the distance between the imaging plane (e.g. the image chip in a digital camera) and a point where all light rays intersect inside the lens (the ‘optical center’). So a focal length of 20mm means that the distance from the optical center to the imaging plane is 20mm long (about ¾ of an inch). What does the focal length number mean?
Focal length is a number that is vital to photography and photogrammetry but often misunderstood. What is focal length?
Figure 1: Modern sensor formats allow for high sensitivity by a combination of high photon collection efficiency and conversion and low noise electronics. This illustration shows a back-illuminated sensor in which the circuitry is beneath the photosensitive region and thus does not block light from reaching the region in which photons may be converted to electrons.
The highly innovative iXon Ultra 888 is the world’s fastest Megapixel, Back-illuminated EMCCD camera, offering exceptional frame rates and single photon sensitivity across a large…
PhotoModeler is one of the leading tools for photogrammetry (the science of generating measurements and accurate 3d data from photography).
The iXon Ultra platform takes the popular back-illuminated 512 x 512 frame transfer sensor and overclocks readout to 17 MHz, pushing speed performance to an outstanding 56 fps (full…
Figure 4: 2x2 binning applied to sensor to boost photon collection across 4 pixels and the signal to noise ratio at the expense of spatial resolution.
What isfocallength oflensclass 10
Matching pixel sizes to microscope field of view and maintaining resolution is discussed more comprehensively in the article: Optimizing field of View and Resolution for Microscopy. In the following sections we will focus on pixel size and photon collection efficiency.
Andor’s new iXon Life EMCCD (Electron Multiplying CCD) platform is available exclusively for fluorescence microscopy applications and is engineered to deliver single photon sensitivity…
Let’s say you take a picture of an automobile with two cameras, a 35mm film camera and a smartphone camera. You stand in the same spot and take two photos, one with each camera. In both cases you want to take a photo of the automobile that fills the frame. If the 35mm film camera lens has a 50mm focal length, the digital camera’s focal length might be 4mm. So even though they are very different numbers they produce the same result because of the size of the imaging surface. So the “equivalent 35mm focal length” for this smartphone camera at 4mm is 50mm.
Figure 5: While binning does not work as well for CMOS as CCD, it still allows a boost in signal to noise compared to without at the expense of spatial resolution.
Using this information we can plot the signal to noise against the number of photons, accounting for illumination intensity over the sensor by expressing photons on an area basis – in this example we will express per 13 µm2 sensor area:
From this we can see that the larger pixel does indeed allow for a higher signal to noise - some ~2.5x higher at 10 photons per 13µm2. This will translate to the following benefits:
For some applications such as single molecule detection, and for high magnification, the larger pixel sCMOS cameras like the Sona-11 can offer some benefits:
Focallength oflensformula
Andor’s new iXon Life EMCCD (Electron Multiplying CCD) platform is available exclusively for fluorescence microscopy applications and is engineered to deliver single photon sensitivity…
Figure 2: Large pixel sizes are used in EMCCD and CCD cameras to gain advantage of the superior photon collection efficiency and improved probability of photon being detected. This example illustrates the relative sizes of 13 µm, 6.5 and 4.6 µm pixel.
There is no one camera that does all imaging scenarios better than every other camera. Thankfully there are now a range of cameras that can be selected to suit different applications that need for example the highest spatial or temporal resolution, or the best possible sensitivity. This means that it is important to consider the application needs first and foremost and not assume that the latest camera model with the largest sensor and most megapixels will be the best option.
The large pixel sizes that these EMCCD and CCD cameras have also plays an important factor in why they remain suitable for these imaging scenarios. When photon collection is the priority, a larger pixel acts effectively as a larger catchment area for photons- feeding in more signal to the sensor. This is why the latest EMCCD sensor designs feature pixel sizes in the range of 13-16 µm which are natively suited to photon collection at high magnification e.g. 100x. Note that EMCCD cameras with smaller pixel sizes are available, but they have not gained any market traction as they do not provide application benefits over large pixel EMCCD, or to sCMOS camera options. In the following illustration, an iXon Ultra 888 EMCCD camera has a 4x higher native pixel area than a typical sCMOS camera and an 8x larger pixel area than the CMOS sensor.
Ideally the sensor size should fit within the uniform region available to the microscope and the pixel size would match the objective and magnification used for imaging. However, this is sometimes not the case for different combination of sensors, microscopes and application requirements. Additional post objective magnification may be used to avoid vignetting effects, or expand the field of view to cover that of a larger sensor area. The other application of additional magnification is to help meet optimal sampling of the image to meet or exceed Nyquist criteria e.g. adding a 2x lens with reduce the pixel size by x2 and help improve spatial resolution, but reduce the field of view. Thus, while useful, there are a number of considerations of using additional lenses in the optical system. This topic is discussed further in the article: Optimizing field of View and Resolution for Microscopy.
Andor’s NEW iKon-XL is a TE-cooled, very large area CCD camera platform, accommodating big field of view sensors that are ideally suited to long exposure astronomy applications.…
In general, CMOS sensors have smaller pixel sizes than EMCCD and CCD sensors. The CMOS sensor architecture also allows higher speeds and larger sensor sizes than CCD based designs. These qualities suit general fluorescence imaging applications allowing good image detail at common magnifications for cell biology studies and have made sCMOS the dominant detector technology for many microscopists.Despite the rise of sCMOS detectors, EMCCD and CCD detectors have remained as the best option for some of the most challenging imaging applications and this looks set to continue for some time to come:• EMCCD cameras use Electron Multiplication to effectively eliminate readout noise. This unique feature makes this sensor technology ideal for making precise quantitative measurements down to even a single photon such as single molecule imaging, but also for live-cell confocal imaging and super resolution systems.• Deep cooled CCD cameras feature orders of magnitude less dark current than CMOS designs making them perfectly suited for long exposure luminescence experiments that are dark current limited and the slower readout of CCD is not a factor.
However, for the more challenging single molecule experiments, the larger pixel size and high QE is not always enough. Electron multiplication process unique to EMCCD sensors boost the signal many fold prior to readout so the signal is far above the noise floor of the camera readout electronics and in practice proven to operate at photon levels below what is possible from any CMOS technology
In table 2 we can see the pixel sizes of a range of current commercially available high performance imaging sensors that may be used for microscopy:
The impact in imaging terms will be that using small pixels may mean a low dynamic range that can result in oversaturation and lose of image information. Therefore, for applications in which a high dynamic range is important a well optimised sensor with larger pixel sizes may be more suitable than one with smaller pixels.
Figure 2: A comparison the effect of pixel size on signal to noise performance of 2 sensors with all factors the same other than pixel size with incident light as photons normalised over per 13 µm.
Note: A technical photogrammetry term that you may come across is the “Principal Distance”. Strictly, the Principal Distance is the distance mentioned above (i.e. distance from imaging plane to the lens optical sensor), and the focal length is the principal distance when the lens is focused at infinity. See below for more information on focus vs focal length. When PhotoModeler lists focal length for a camera, it is actually the Principal Distance that is shown.
Smaller pixels can be binned – whereby the signal in a number of pixels may be pooled together to increase the overall signal level. A common example would be 2x2 binning which would group the signal for 4 pixels together as shown in figure 3. This works effectively for CCD in boosting speed and sensitivity as the serial nature of CCD allows each pixel value to be added before a read noise is added. Binning also works especially well outside of imaging for spectroscopy measurements as vertical binning may be applied without concern of losing resolution in the y axis.
One of the trends that can be seen in microscopy in recent years has been the interest in imaging sensors with larger fields of view and smaller pixel sizes to maintain image detail when working at lower magnifications such as 20x. But are smaller pixels always better, or are there still conditions in which larger pixels are advantageous? In this article we consider pixel size and whether larger pixel sizes are still useful, and if so, where may this apply.
Modern digital cameras can have imaging chips that are as small as 6mm by 4mm; some Smartphone cameras are even smaller, and then up to full 24mm by 35mm size. A very common size is the APS-C format at 16mm by 24mm. This smaller size affects what is considered to be a ‘normal’ focal length.