Image

There are 9 classes of dangerous goods. Some are also subdivided into divisions. Learn more about what they are and which ones are most commonly used.

FloorBunding

A basic introduction to good environmental management that will help you avoid pollution incidents. This guidance refers to information in other PPGs and publications. This PPG is currently being reviewed and will be updated in 2012.

This section represents interim guidance, as PPSLG will undertake further work to develop more detailed guidance on secondary and tertiary containment.

Thus the TK-Bund design incorporates in the bund section a fully incorporated and installed alloy meshing which will not only stop the spilled fuel flames continuing to burn but also in a extreme case scenario in allowing the fire services to easily extinguish any flames by using TK-Anti Fire Textiles Blankets, foams or even water.

Can you see the storage tank vent? If not you are required to bund the tank. An Overfill Prevention Valve will also need to be fitted in this instance.

It is reasonably easy to construct a "water-tight" bund around the base of a tank or vessel. A concrete base and a sealed wall of masonry, brickwork, concrete or even prefabricated steel provides the holding capacity.

The TK-bund normally has a mobile, flexible cover or roof to prevent precipitation, climatic changes,dirt, debris from getting in, but procedures are taken to provide adequate ventilation when storing flammable liquids. Another design uses a channel that drains the liquid to a secondary containers.

Bundingwall

The Environment Agency is able to impose uncapped fines on anyone who causes any spill, it is not necessarily the responsibility of the site owner as it is the polluter who pays.

Good practice guidance to help you produce an incident response plan for your site to deal with accidents, spills and fires. Using this guidance will help to protect the environment. View PDF Dealing with spills: PPG 22, April 2011 Good practice guidance to help you plan how you will respond to a spill on your site or if you are transporting materials. Includes information about the pollution control hierarchy and pollution control equipment options. View PDF Environment Agency Technical Information Notes Pollution prevention: Safe storage and use of de-icing products (issued December 2010) Advice and guidance on the safe storage and use of de-icer products together with their potential environmental impacts. View PDF Pollution prevention: Airfield management (updated April 2011) Advice to protect the environment from common activities at private, commercial and military airfields. View PDF Prevent pollution from drinking water treatment works and distribution networks Advice to protect surface waters and groundwater from activities at water treatment works and distribution networks. View PDF EU/UK SAFETY AND ENVIRONMENTAL DATA View PDF Above ground oil storage tanks using bunds View PDF Safety and environmental standards for fuel storage sites View PDF Guidance on the Environment (Oil Storage) Regulations View SEPA Guidance Products Safety Products System Video Product Presentation Anti Explosion Blast System Anti Explosion Alloy Products Anti Explosion Manhole Systems Anti Explosion Gas Cylinders Anti Explosion Fuel Cans Fire/Thermal/Bullet Proof Panels Bullet Proof Security Panels Fire Rated Doors Panic Rooms/Bunkers Detector y Sistema de Evacuación de Gases Anti-Electronic Pulse EMPS/EMI Strategic National Industries Safe Haven Rescue/Fire/Safety/Humanitarian/Sea/River/Land/Aerial Mobile Bases Helipads / Heliports Oil Tankers, Barges, Ports, Vessels Protection, Safety, Security & Efficiency Technologies SAR-Search & Rescue Services Anti Fire/Heat Safety Blanket • Tecnologías de Seguridad Activa y Pasiva (Spa) Climate, Electrostatic, Oxidation Safety Properties Anti-Fire/Heat/Explosion Mobile Telecom Nanotechnologies Pipelines, Fracking & Pumping Stations Environmental Damage and Safety Emergency Life Pod Evacuation Station Arts Mobile Security Container Systems Anti-Blast Mobile Shields & Barriers Smart Delivery Box Bunding Safety Systems Eco-Energy Power Plants TK-Global Environment TK Meteor 6000 Recycling Plant TK Omega RF5000 Electromagnetic (Spa) TK Orion RF5000 Electromagnetic TK Meteor 4000 Recycling Plant (Eng) TK Meteor 4000 Planta de Reciclaje (Esp) Environmental Mobile Decontamination & Recycling Technologies Solar Heating Water Plant • Solar Desalination Plant • Climate, Electrostatic, Oxidation Safety Properties TK Aviation Aviation Industry The Eagle Eye Aviation Programme Eagle Eye I Private/Sport Eagle Eye II Crop Buster Eagle Eye III Law Enforcement 2 Seater Eagle Eye IV Law Enforcement 5 Seater Bimotor Eagle Eye V Search & Rescue/Medi-Vac Eagle Eye VI Bullion Security Carrier Eagle Eye VII Luxury 2 Seater • Eagle Eye VIII Luxury 5 Seater Bimotor • Eagle Eye IX Anti-Submarine/Deep Sea R&D Eagle Eye X-RF5000 • Alien Black Night Viper Aircraft (Eng) Alien Black Night Viper Aircraft (Spa) Alien BNV Short Tail Aircraft (Diesel Engine) Alien BNV Medium Tail Aircraft (Petrol Engine) • Alien BNV Long Tail Aircraft (Jet Engine) • Alien BNV X-RF5000 (Electromagnetic Engine) • Aircraft Airbag, Parachute, Anti-Thermal/Fire Safety Technologies Anti Fire/Heat Fuselage • Anti Explosion Aeronautical Fuel Tanks Viper Sting Ray - Visual Detection Technologies Airport Fuel Security & Safety Helipads / Heliports SAR-Search & Rescue Services Climate, Electrostatic, Oxidation Safety Properties Environmental Industries TK-Global Environment The Eye of Osiris National Security Food Plant Environmental Mobile Decontamination & Recycling Technologies Anti Contamination Industrial CO2 Filter Systems Anti Heat/Fire Industrial Cooling Systems TK Solar Heating Systems TK Meteor 6000 Recycling Plant TK Meteor 4000 Recycling Plant (Eng) TK Meteor 4000 Planta de Reciclaje (Esp) Tecnologías de Prevención de Accidentes Medioambientales (Spa) Climate, Electrostatic, Oxidation Safety Properties Pipelines, Fracking & Pumping Stations Environmental Damage and Safety Bunding Safety Systems Mining Anti Explosion Mobile Defence Barriers • Anti Explosion Mining Gas Detectors • Petroleum Industry Petroleum Industry Overview Anti Explosion Petrol Station System Anti Explosion/Anti Fire Fuel Valve Válvula Anti Explosión/Anti Fuego (Spa) Anti Explosion Fuel Chemical Tanks Anti Explosion Pipelines Systems Anti Explosion Oil Rig Systems Anti Explosion Fuel Tank Floating Roof System Anti Explosion Strategic Fuel Tanks Anti Explosion Mobile Fuel Tanks Pipeline Acoustic Security Detection Anti Explosion Pipeline Bypass Systems • Anti Explosion Pipeline Revolver System • Anti Explosion Fuel Bunkering System • Anti-Explosion Safety Building Fuel Storage Tanks Depósitos de Combustible de Edificios Anti-explosivos (Spa) Airport Fuel Security & Safety Anti-Electronic Pulse EMPS/EMI Strategic National Industries Safe Haven Exploration/Drilling Sea/River/Land/Mobile Bases Oil Tankers, Barges, Ports, Vessels Protection, Safety, Security & Efficiency Technologies Helipads / Heliports SAR-Search & Rescue Services TK Meteor 6000 Recycling Plant Tecnologías de Seguridad en la Industria Petroquímica (Spa) Climate, Electrostatic, Oxidation Safety Properties Pipelines, Fracking & Pumping Stations Environmental Damage and Safety Anti-Blast Mobile Shields & Barriers Bunding Safety Systems Industrial Projects TK-Global Environment The Eye of Osiris National Security Food Plant TK-GCMR Refinery (Eng) TK-GCMR Refinery (Spa) TK Rubber/Plastic Refinery Plant TK Refinería de Goma/Plásticos TK Emergency Safety Housing (Spa) Airport Fuel Security & Safety Environmental Mobile Decontamination & Recycling Technologies Climate, Electrostatic, Oxidation Safety Properties Anti-Fire/Heat/Explosion Mobile Telecom Nanotechnologies Bunding Safety Systems Maritime Industry Maritime Industry Overview King Shark I Light Armoured Patrol Vessel King Shark II Heavy Armoured Patrol Vessel King Shark III Aircraft Carrier King Shark IV Submarine Carrier King Shark V Assault Troop Carrier King Shark VI Fuel Carrier King Shark VII Logistical Cargo Carrier King Shark VIII Plasma Fusion Gunship King Shark IX Missile Launcher King Shark X Emergency/Hospital King Shark XI Helicopter Carrier King Shark XII Fire Services Heliport King Shark XIII Fire Services Long Ladder King Shark XIII Fire Services Unmanned Ladder King Shark XIV Long Range Radar King Killer Whale / Heavy Aircraft Carrier Anti Explosion Shipping Containers • Anti Explosion Fuel Tanks • Anti Explosion Heat/Fire Safety Systems • Vessel Traffic Services (VTS)/Auto Identification Services (AIS) Sistema de Tráfico de Buques (VTS)/ Sistema de Identificación Automática (AIS)-(RAIS) Maritime & Submarine Technologies (SPA) Viper Sting Ray - Visual Detection Technologies Oil Tankers, Barges, Ports, Vessels Protection, Safety, Security & Efficiency Technologies Helipads / Heliports SAR-Search & Rescue Services Military Vehicles 4x4 EBNV Stinger ATV EBNV Protector (HMLC) 4x4 Desert Dragon 4x4 Dragon Slayer 6x6 Dragon Fighter 6x6 Dragon King Fighter 9x9 Dragon Warrior 9x9 Dragon King Warrior Viper Sting Ray - Visual Detection Technologies Safe Haven Logistical Sea/River/Land/Aerial Mobile Bases Transportation & Auto Transportation & Auto Overview TK Transportation Industry TK Auto Industry TK Auto LPG Fuel Tanks TK Auto Hydrogen Fuel Tanks TK Gas Conversion Kits Anti Explosion Gas Cylinders Detector y Sistema de Evacuación de Gases Environmental Mobile Decontamination & Recycling Technologies Construction Industry Construction Industry Overview Anti Fire/Heat Wall Panels Anti Fire/Heat Panels Anti Fire/Heat Duct System Anti Fire/Heat Collar System Anti Electro Magnetic Pulse Technology Anti-Explosion Safety Building Fuel Storage Tanks Depósitos de Combustible de Edificios Anti-explosivos (Spa) Fire/Thermal/Bullet Proof Panels Bullet Proof Security Panels Fire Rated Doors Home/Office Panic Rooms/Bunkers Detector y Sistema de Evacuación de Gases Emergency Life Pod Evacuation Station Anti-Blast Mobile Shields & Barriers Bunding Safety Systems Global Food Industry Eye of Osiris Ojo de Pachamama The Eye of Osiris National Security Food Plant Eagle Eye II Aerial Crop Buster Anti-Electronic Pulse EMPS/EMI Strategic National Industries Electronic Safety Systems TK-Global Electronics TK-Global Technotelecom G2/G3/G4 Communication Technologies Anti-Fire/Heat/Explosion Mobile Telecom Nanotechnologies Tecled-Technoleds LED Lights (Spa) Fibre Optics for Security & Safety Anti Gas Detector System • Anti Electro Magnetic Pulse System Acoustic Detection Technologies Vessel Traffic Services (VTS)/Auto Identification Services (AIS)-(RAIS) Sistema de Tráfico de Buques (VTS)/ Sistema de Identificación Automática (AIS)-(RAIS) Viper Sting Ray - Visual Detection Technologies Detector y Sistema de Evacuación de Gases Climate, Electrostatic, Oxidation Safety Properties Arts Mobile Security Container Systems Smart Delivery Box Housing Projects TK-Global Technotelecom G2/G3/G4 Communication Technologies Military / Police / Security Buildings Edificios Militares / Seguridad / Policiales Emergency/Social Housing Projects Viviendas de Emergencia/Sociales Quick Build Housing Viviendas de Construcción Rápida Building Security & Safety Seguridad en Edificios Fire/Thermal/Bullet Proof Panels Bullet Proof Security Panels Fire Rated Doors Home/Office Panic Rooms/Bunkers Detector y Sistema de Evacuación de Gases Arts Mobile Security Container Systems Anti-Blast Mobile Shields & Barriers Smart Delivery Box • Access only for associates What is B.L.E.V.E. explosion? B.L.E.V.E. Explanation Video TechnoKontrol Wikipedia TK Wikipedia English TK Wikipedia Spanish TechnoKontrol: 1st in Spain for own Technology patents 2013 & 2014 Ministerio de Industria Turismo y Comercio-OEPM Technokontrol, the number 1 corporation in Spain filing for its own technology patents, trademarks and utility patents (SPA) OEPM 2013 The year in numbers (SPA) TechnoKontrol has been fully verified and certified by Bureau Veritas Certificates ISO 9001 - ES108784-1 ISO 14001 - ES108782-1 ISO 45001 - ES108783-1 ISO 4126 ISO 28000 ISO 37000 NFPA-National Fire Protection Association Description NFPA-Asociación Nacional de Protección contra el fuego Descripción NFPA Fire Analysis and Research Division - Large Loss Fires in the United States 2012 TechnoKontrol is a member of the NFPA US NFPA Standards on Explosion Prevention Systems 2008 NFPA 69: Standard on Explosion Prevention Systems, 2016 Edition Prevent deflagration explosions due to combustible dust particles, gases or vapors with NFPA 69. Combustible dust, gases and vapors produced in industrial settings can pose a significant safety hazard.NFPA 69: Standard on Explosion Prevention Systems offers definitive guidance on explosion protection and prevention systems. ATEX - European Antiexplosive Safety Directives ATEX Guide: Protection in explosive atmospheres ATEX-EU/HAZLOZ-USA/NFPA-USA/DSEAR-UK/Explosion Directives TechnoKontrol Additional Anti-Explosion Data ATEX Directive in EU Directives Dangerous Substances and Explosive Atmospheres Regulations - United Kingdom/ATEX The Dangerous Substances and Explosive Atmospheres Regulations United Nations Economic Commission for Europe - UNECE - TechnoKontrol TechnoKontrol information for the UNECE BLEVE working group Proposal transmitted by the governments of Spain and France The European Parliament and The Council Protective Systems & Equipment Intended for the use in Potentially Explosive Atmospheres Technokontrol's Products & Services are insured by Dossiers TK Group of Companies Deflektor Exco-Systems Exco Exess ExploSafe ExploStop Riskontrol TK-Global Engineering - Where efficiency and reliability become a reality Video of Product Installation Process BP World Report BP Statistical Review of World Energy Full Report 2012 Static Electricity Dangers and Protection Static Electric Discharge Hazard On Bulk Oil Tank Vessels Static Electricity - ISGINTT Dangers of static electricity and protection in aviation Static Electricity - IAPA U.S. Chemical Safety and Hazard Investigation Board US Department of Transport US Emergency Response Video Pt. 1 US Emergency Response Video Pt. 2 USA Chemical Safety Board An independent federal agency investigating chemical accidents to protect workers, the public, and the environment. About the CSB About the Chemical Safety Board CSB Safety Videos Chevron Richmond Refinery Explosion Deadly Contact West, Texas Real Live Blast Damage Video Hot Work - Dupont Explosion Static Sparks Explosion in Kansas Danger of Flammable Gas Accumulation Articles Energy Sector Vulnerabilities: Petroleum (Spanish) Security Fire and Explosion in the Liquified Petroleum Gas Facility (ENG) Petrol Station Explosions Caused by Electrostatic Risks (SPA) Los riesgos de ignición electrostática en las gasolineras-KPS (SPA) Vaporización en gasolineras (SPA) Procedimientos de seguridad en terminales de hidrocarburos (SPA) Techno Roof Techno Roof 1 Techno Roof 2 Techno Roof 3 Independent Explosion Reports Report of Tank Washing Risks Report of Jumbo Tank Explosion Report of History of Storage Tank Explosions

Bunding is a legal requirement in many countries particularly around tanks, storage vessels and other plant that contain liquids which may be dangerous or hazardous to the environment.

The TK Cages are made of stainless steel and inside their main frame tubular structures they are also filled with TK-Alloys to increase and able to withstand maximum thermal radiation, heat, flames and liquid movement in the event of the deposit, fuel tank suffering partial or complete structural failure a sin an explosion or boilover scenario.

Advice to help you protect the environment when you're washing vehicles using automatic wash systems, high pressure or steam cleaners and washing by hand.

Image

The Environment Agency are able to impose uncapped fines on anyone who causes any spill, it is not necessarily the responsibility of the site owner as it is the polluter who pays.

If you are planning works near, in or over water, this guidance provides advice on how to make sure your work protects the environment and meets legal requirements, including waste management.

Spillbunding

Particular examples which receive specific attention in the UK, the rest of Europe and the USA are oil and fuel storage tanks and transformers at electricity sub-stations which are filled with oil for cooling and insulation purposes.

The TK-bunding must be large and strong enough to contain the contents of an entire tank, though regulations may require it to be up to a third larger. When multiple tanks share a bund, the capacity is based on the largest tank. One of the most common designs for large tanks is a concrete or masonry wall around the tank with a concrete floor. The outside of the wall may be reinforced with an earth

You may be prosecuted and fined if oil from your site enters the ground or watercourses. And you may have to pay substantial clean-up costs. The Oil Storage Regulations are designed to prevent oil spills.

Once the spilled fuels are safely located in the bund section these can be then drained into any emergency, environment protection drainage, pipeline, tank system or even being pumped back into any road tanker for fuel cleaning/filtering and being able to be re-used, if so desired, as the fuels chemical composition shouldn´t have changed and only being an issue the possible mixture with external debris thus recommending a full filtration and analysis before its re-use in its original form or in form of other products thus reducing product and financial loss.

Bundingmeaning

If you are installing an oil tank and/or connecting pipe work and you employ an installer registered with one of the related competent person schemes, you will not need to involve a Building Control Service

TK-Bunding Safety Structures are constructed retaining walls designed to prevent inundations or breaches from a known source. They are secondary and third containment systems commonly used to protect environments from spills where fuels and chemicals are stored.

If it is not possible to meet these requirements, a fire rated barrier with at least 30 minutes protection should be provided, extending 300mm higher and wider than each applicable face of the tank.

The TK Cages are designed to fit perfectly into the TK Bund Area thus allowing the maximum protection due to its direct contact with the TK-Alloys but also allowing maximum contact, covering, protection with and around metal pipes, pipelines, cabling, metal structures as fuel tanks, store facilities, pumping stations.

You should also provide secondary containment (Bunded Tank) if the oil storage tank falls within a 10m of a water course (stream etc). Also use secondary containment if within 50m of a potable water supply or where spillages could run into drains or reach controlled waters.

Guidance for the construction of simple, reinforced masonry bunds for oil storage tanks up to 3.5 metres wide and 1.2 metres high.

Advice on storing and disposing of used oils safely. This information applies to those carrying out a single engine oil change, to large industrial users. This PPG is currently being reviewed and is due to be updated in 2012.View / Download Guidance for site drainage, dealing with sewage and trade effluents

This guidance note covers all underground storage tanks (USTs), including those containing petroleum, diesel, fuel oil, aviation fuel, waste oil, domestic heating oil and other potentially polluting materials such as organic solvents. This PPG is currently being reviewed for updating in 2012.

WorkSafe Victoria is committed to safe and inclusive work places, policies and services for people of LGBTIQ communities and their families.

Having these TK-Bunding Safety Systems incorporated in the bund structure allowing that even any continuous thermal flame, fire, heat exposure, radiation over many hours or even days being structurally prepared to support the bund structure integrity and even more importantly not allowing the liquids spilling over or penetrating into any other bunds, drainage, sewage systems thus not only reducing the risk of thermal flame or fire exposure from one site to another but also in protecting the environment and following any QSSHE corporate and/or government directives.

Site-specific planning of firewater management and control measures should be undertaken with active participation of the local Fire and Rescue Service, and should include consideration of:

Bundingart

What isbundingin agriculture

LEVEL 1 + LEVEL 4. THE BUND INTERNAL SECTION SURROUNDING THE STORAGE TANK AT 110% MAXIMUM TOTAL FUEL STORAGE TANK VOLUME.

Almost all regulations require a holding capacity of 110% of the largest tank within the bund or 25% of the total capacity of all the tanks within the bund whichever is the greatest. In addition further guidelines in some countries (e.g. the UK) recommend additional measures such as providing sufficient "freeboard" or height of wall above the maximum holding capacity to accommodate dynamic factors such as surge in situations of major tank failure or storm driven waves in larger bunds. As a rule (and unless specific local laws prevail) most operators work to the 110% capacity guide.

The issue of having installed a specialist protection TK-Bund structure to withstand any amount of fuels, chemicals and/or liquids has been pointed out above but the most serious scenario being that the fuels once haven spilled into the bund structure being ignited and causing the storage, jumbo tank in being imbedded into a fuel fire pool/bund which again increasing the possibility of not only of the increasing of the fire but also creating a perfect environment for a BLEVE explosion.

Prevent deflagration explosions due to combustible dust particles, gases or vapors with NFPA 69. Combustible dust, gases and vapors produced in industrial settings can pose a significant safety hazard.NFPA 69: Standard on Explosion Prevention Systems offers definitive guidance on explosion protection and prevention systems.

Once the spilled ignited fuels enter into the bund section, then the TK-alloys will not allow the fuel to continue its burning process. The bund will not lose its safety directive minimum volume capacity as having the TK-Alloys installed will only have a total liquid volume loss of 1%-2% depending on the final design.

Oil storage Regulations Definition: Secondary Containment, also often referred to as a bunded fuel storage tank, under the Oil Storage Regulations, an oil storage tank which qualifies should be contained within a secondary containment system totaling no less than 110% of the storage tanks full capacity, a bunded oil tank.

If this is not possible, walls or barriers of at least 60 minutes resistance which extend 900mm beyond each applicable face of the tank should be used. (120 minutes rating for tanks above 3500L capacity).

Bundingmeaning construction

The bund is also fully protected against oxidation, corrosion thus the external part of the fuel tanks which sit inside the TK-Bund section benefiting from the TK-Alloy its physical contact with the alloys/metal in reducing oxidation, electrostatic charges, electromagnetic waves, etc. The spilled fuels inside the bund will also have the benefit of not creating or developing algae thus located spilled fuels not emitting fuel decomposition odours.

Information to help you store and use emission reduction solutions (for example, AdBlue) safely, so they don't damage the environment.

The failure of secondary and tertiary containment at Buncefield contributed significantly to the failure to prevent a major accident to the environment (MATTE).

WorkSafe Victoria acknowledges Aboriginal and Torres Strait Islander people as the Traditional Custodians of the land and acknowledges and pays respect to their Elders, past and present.

Many drains lead directly to rivers, streams or lakes. If you allow oil to enter these drains, it has the same effect as pouring it directly into the watercourse.

Bunded oil tanks are generally a requirement from most insurance companies as opposed to single skinned oil storage tanks. Due to the safer oil storage solutions brought about by bunded oil storage tanks, some places in the UK can see the Environmental Agency require you to install bunded oil tanks.

Joints in concrete or masonry bund walls must be capable of resisting fire. Existing bunds should be modified to meet this requirement. In addition to repairing any defects in bund joints, steel plates should be fitted across the inner surface of bund joints, and/or fire-resistant sealants should be used to replace or augment non-fire-resistant materials.

LEVEL 1 + LEVEL 2. THE BUND INTERNAL SECTION SURROUNDING THE STORAGE TANK AT 25% MINIMUM TOTAL FUEL STORAGE TANK VOLUME.

Oil is poisonous to fish and other wildlife and it smothers plants. Just two liters of oil could seriously pollute the volume of fresh water needed to fill an Olympic-size swimming pool and make it undrinkable.

Section 7 of the PPG26 pollution prevention guidelines states: “Spill kits containing materials such as oil or chemical absorbents and personal protective clothing should be on site”.

Types ofbunding

While priority should be given to preventing a loss of primary containment, adequate secondary and tertiary containment remains necessary for environmental protection in the event of a loss of primary containment of hazardous substances.

These guidelines will help you if you are responsible for storing and handling drums and Intermediate Bulk Containers (IBCs). They are written for site operators of industrial and commercial premises.

On older sites masonry bund walls are still in use. Vertical expansion and contraction joints and penetration joints rely on sealants to keep the bund watertight. These may require improvement to fire resistance. In addition, where significant cracks in masonry joints have been repaired with flexible sealant, these may also require improvement.

PPG 20, March 2001 Provides information for the safe dewatering of underground ducts and inspection chambers. This guidance is due to be reviewed and updated in 2012.

PROTECTING THE TK-BUND STRUCTURE WITH THERMAL, FIRE, FLAME PROTECTION TK-ALLOYS/TK PANELS TO CONTAIN A FUEL FIRE OF A MINUMUM OF 6 HOURS AT 900º-1150ºC.(INTERNAL, INSIDE TO TANK, GROUND BUND WALL SECTIONS).

The Oil Storage Regulations apply to all new installations in the UK- (both domestic and commercial). Oil is the commonest pollutant in the UK, accounting for one quarter of all incidents. These guidelines are intended to help reduce pollution caused by inadequate storage of oil in above ground oil storage tank installations.

Below is a list some of the most commonly used dangerous goods and their class or division. These substances may be dangerous depending on their concentration.

The vaporization of any spilled fuel or chemicals being reduced are other benefits of the TK-Alloys and also protecting the whole structure against lightings, sparks, maintenance operation errors, etc.

Planning permission is also required for any domestic storage tank for fuels other than for oil fired heating applications (i.e.: LPG).

LEVEL 1 + LEVEL 4 + LEVEL 5. THE INSIDE OF THE STORAGE TANK FULLY PROTECTING WITH TK-ALLOYS WITH THE COMPLETE INTERNAL CAPACITY AND ALSO BEING FULLY PROTECTED THE TK-BUND AREA. THUS CREATING THE MAXIMUM LEVEL OF QSSHE PROTECTION POSSIBLE GLOBALLY.

Class 4: Flammable solids; substances liable to spontaneous combustion; substances which, on contact with water, emit flammable gases

Advice on how to store oil safely in above ground oil storage tanks and comply with the law (excludes oil refineries and distribution depots).

The European Commission’s Joint Research Centre and the Belgian Federal Public Service of Employment, Labour and Social Dialogue, Chemical Risks Inspection Division

Technokontrol Manufactures, Designs & Researches our safety products in the European Union at the highest possible International Accident,Health & Safety standards.

The TK Bund Area is mapped out in 3D thus allowing a color, numeric and precise cage plan design allowing when needed to withdraw, relocate, transport, have access to all sectors inside the TK Bund Area and/or to do maintenance, cleaning, QSSHE operations at anytime as being easily transportable by means of light weight lifting machinery, cranes or even by several members of staff due to its extreme light weight properties.

A fire could be started by a fuel storage tank and its contents, However it does need to be protected from a fire that may originate nearby.

Good practice guidance to help you plan how you will respond to a spill on your site or if you are transporting materials. Includes information about the pollution control hierarchy and pollution control equipment options.

Your environmental regulator can serve on you an 'anti pollution works notice' if your site gives rise to, or is at risk of giving rise to, pollution of surface waters or groundwater. This notice will require you to undertake remedial action.

The TK-Bunding Structures have the great benefit of not only containing the stored liquids in case of an incident or emergency from the storage tank breakage, fire, explosion, boilover but also being designed and having incorporated inside the bund structure two thermal, fire and flame protection systems which in the event of an fire, explosion or even the disastrous boilover scenario the spilled fuels or chemicals which are extremely flammable and to which most possibly being ignited can´t weaken and/or melt the bund structure due to the massive, continuous thermal radiation reaching over the 900ºC in the event of a fuel fire from the storage tank.

Section 5.1 (b) iii of the above regulations also states that all oil tanks should be labeled with information on how to respond to a leak.

OFTEC recommend that non domestic tanks equal to or below 3500L capacity should be located a minimum of 2m away from any buildings or boundaries. (6m for tanks above 3500L capacity).

A guide to looking after your above ground oil storage tank and avoiding pollution, written together with the Oil Firing Technical Association and the Federation of Petroleum Suppliers. We recommend you have a look if you’ve got a new tank at your home or business or if you’ve moved into premises with a tank.

Image

These guidelines describe good practice in fuel storage and management that can reduce the environmental risk of your site. These guidelines also refer to the storage and handling of other liquids commonly used in association with fuel storage and dispensing.

Bund wall and floor construction and penetration joints should be leak-tight. Surfaces should be free from any cracks, discontinuities and joint failures that may allow relatively unhindered liquid trans-boundary migration. As a priority, existing bunds should be checked and any damage or disrepair, which may render the structure less than leak-tight, should be remedied.

To help you decide if you need an oil separator at your site and, if so, what size and type of separator is appropriate. The separators listed in the document below have passed the performance type test in accordance with Clause 8.3.3 of the European Standard for Separator Systems, BS EN 858-1:2002:

The TK Bund Area can be filled with different levels of TK Safety alloys which are transported, installed, stored in custom made -designed TK- Cages to withhold, secure, store the TK Safety Alloys during its operational life.

Advice and guidance on the safe storage and use of de-icer products together with their potential environmental impacts.